The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
A magnetic microstirrer and array for microfluidic mixing
Abstract
We report the development of a micromachined magnetic-bar micromixer for microscale fluid mixing in biological laboratory-on-a-chip applications. The mixer design is inspired by large scale magnetic bar mixers. A rotating magnetic field causes a single magnetic bar or an array of them to rotate rapidly within a fluid environment. A fabrication process of the magnetic bar mixer is developed. Results of fluid mixing in micro channels and chambers are investigated using experimental means and computer-aided fluid simulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Characterization of Mixing in Micromixers by a Test Reaction: Single Mixing Units and Mixer Arrays
Ehrfeld, W., Golbig, K., Hessel, V., Löwe, H., & Richter, T. (1999) · Industrial & Engineering Chemistry Research · doi:10.1021/ie980128d · Cited by 375
Micro mixer with fast diffusion
Miyake, R., Lammerink, T. S. J., Elwenspoek, M., et al. (2002) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.1993.296914 · Cited by 141
Chaotic Mixing In Electrokinetically And Pressure Driven Micro Flows
Lee, Y.-K., Deval, J., Tabeling, P., & Ho, C. (2001) · Springer eBooks · doi:10.1007/978-3-642-56763-6_20 · Cited by 139
Relation between Flow Pattern and Blending in Stirred Tanks
Patwardhan, A. W., & Joshi, J. B. (1999) · Industrial & Engineering Chemistry Research · doi:10.1021/ie980772s · Cited by 122
Chaté, H., Villermaux, E., & Chomaz, J. (1999) · Medical Entomology and Zoology · Cited by 62
Fluidics-the link between micro and nano sciences and technologies
Ho, C. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2001.906556 · Cited by 53
Droplet-based nano/picoliter mixer using hydrophobic microcapillary vent
Hosokawa, K., Fujii, T., & Endo, I. (1999) · doi:10.1109/memsys.1999.746860 · Cited by 49
Cited by
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Pamme, N. (2006) · Lab Chip · doi:10.1039/b513005k · Cited by 1,129
Microchemical systems for continuous-flow synthesis
Hartman, R. L., & Jensen, K. F. (2009) · Lab on a Chip · doi:10.1039/b906343a · Cited by 508
Liquid metal enabled microfluidics
Khoshmanesh, K., Tang, S.-Y., Zhu, J. Y., Schaefer, S., Mitchell, A., Kalantar-zadeh, K., & Dickey, M. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00046d · Cited by 458
Mixing in microfluidic devices and enhancement methods
Ward, K., & Fan, Z. H. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/9/094001 · Cited by 453
Metadata
- Authors
- Lu, L.-H., Ryu, K. S., & Liu, C.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2002-10
- Volume
- 11
- Issue
- 5
- Pages
- 462-469
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2166099222
- Cited by
- 446
- References
- 10
- FWCI
- 12.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.