Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer

Griss, P., Stemme, G. · 2003 · Journal of Microelectromechanical Systems

Abstract

We present the first hollow out-of-wafer-plane silicon microneedles having openings in the shaft rather than having an orifice at the tip. These structures are well suited for transdermal microfluidic applications, e.g., drug or vaccine delivery. The developed deep-reactive ion etching (DRIE) process allows fabrication of two dimensional, mechanically highly resistant needle arrays offering low resistance to liquid flows and a large exposure area between the fluid and the tissue. The presented process does not require much wafer handling and only two photolithography steps are required. Using a 3×3 mm2chip in a typical application, e.g., vaccine delivery, a 100 μl volume of aqueous fluid injected in 2 s would cause a pressure drop of less than 2 kPa. The presented needles are approximately 210 μm long.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jmems.2003.809959

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 232

Metadata

Authors
Griss, P., & Stemme, G.
Venue
Journal of Microelectromechanical Systems
Published
2003-06
Volume
12
Issue
3
Pages
296-301
ISSN
1057-7157 (ISSN-L)
OpenAlex
W2132756315
Cited by
232
References
0
FWCI
9.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer. https://app.cochat.ai/papers/10.1109/jmems.2003.809959
The paper
Griss, P., & Stemme, G. (2003). Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2003.809959

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.