The DOI matches its Crossref record.
Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
Abstract
We present the first hollow out-of-wafer-plane silicon microneedles having openings in the shaft rather than having an orifice at the tip. These structures are well suited for transdermal microfluidic applications, e.g., drug or vaccine delivery. The developed deep-reactive ion etching (DRIE) process allows fabrication of two dimensional, mechanically highly resistant needle arrays offering low resistance to liquid flows and a large exposure area between the fluid and the tissue. The presented process does not require much wafer handling and only two photolithography steps are required. Using a 3×3 mm2chip in a typical application, e.g., vaccine delivery, a 100 μl volume of aqueous fluid injected in 2 s would cause a pressure drop of less than 2 kPa. The presented needles are approximately 210 μm long.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro Total Analysis Systems. Recent Developments
Vilkner, T., Janasek, D., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac040063q · Cited by 968
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Microneedle, bio-microneedle and bio-inspired microneedle: A review
Ma, G., & Wu, C. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.011 · Cited by 477
Microneedles for intradermal and transdermal drug delivery
Tuan-Mahmood, T.-M., McCrudden, M. T. C., Torrisi, B. M., McAlister, E., Garland, M. J., Singh, T. R. R., & Donnelly, R. F. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.05.005 · Cited by 468
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Metadata
- Authors
- Griss, P., & Stemme, G.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2003-06
- Volume
- 12
- Issue
- 3
- Pages
- 296-301
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2132756315
- Cited by
- 232
- References
- 0
- FWCI
- 9.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer. https://app.cochat.ai/papers/10.1109/jmems.2003.809959
- The paper
- Griss, P., & Stemme, G. (2003). Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2003.809959
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.