Cited by 413Advancements in Transdermal Drug DeliveryMicrofluidic and Capillary Electrophoresis ApplicationsAdvanced MEMS and NEMS Technologies

Silicon micromachined hollow microneedles for transdermal liquid transport

Open access
Gardeniers, H.J.G.E., Luttge, R., Berenschot, E.J.W., de Boer, M.J., Yeshurun, S.Y., Hefetz, M., van-t Oever, R., van den Berg, A.·2003·Journal of Microelectromechanical Systems

Abstract

This paper presents a novel process for the fabrication of out-of-plane hollow microneedles in silicon. The fabrication method consists of a sequence of deep-reactive ion etching (DRIE), anisotropic wet etching and conformal thin film deposition, and allows needle shapes with different, lithography-defined tip curvature. In this study, the length of the needles varied between 150 and 350 micrometers. The widest dimension of the needle at its base was 250 μm. Preliminary application tests of the needle arrays show that they are robust and permit skin penetration without breakage. Transdermal water loss measurements before and after microneedle skin penetration are reported. Drug delivery is increased approximately by a factor of 750 in microneedle patch applications with respect to diffusion alone. The feasibility of using the microneedle array as a blood sampler on a capillary electrophoresis chip is demonstrated.

Integrity signals

Registry

Crossref · 10.1109/jmems.2003.820293

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A.
Affiliations
  • University of Twente (NL)
  • Google (Israel) (IL)
Venue
Journal of Microelectromechanical Systems
Published
2003-12
Volume
12
Issue
6
Pages
855-862
ISSN
1057-7157 (ISSN-L)
OpenAlex
W2533221106
Cited by
413
References
31
Citations by year
2026: 8 · 2025: 14 · 2024: 13 · 2023: 19 · 2022: 13 · 2021: 17 · 2020: 21 · 2019: 22 · 2018: 17 · 2017: 16 · 2016: 17 · 2015: 22 · 2014: 18 · 2013: 24 · 2012: 20
FWCI
13.85
Type
journal article
Language
en
Open access
Locations
  • Journal of Microelectromechanical Systems (publishedVersion)
  • TU/e Research Portal (publishedVersion)
  • TU/e Research Portal (submittedVersion)
  • University of Twente Research Information (submittedVersion)
  • University of Twente Research Information (submittedVersion, other-oa)
Funders
University of Twente
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
Keywords
hollow microneedles, silicon micromachining, transdermal drug delivery, deep reactive ion etching, anisotropic wet etching, microneedle arrays, skin penetration, transepidermal water loss, microneedle patch

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review