Silicon micromachined hollow microneedles for transdermal liquid transport
Open accessAbstract
This paper presents a novel process for the fabrication of out-of-plane hollow microneedles in silicon. The fabrication method consists of a sequence of deep-reactive ion etching (DRIE), anisotropic wet etching and conformal thin film deposition, and allows needle shapes with different, lithography-defined tip curvature. In this study, the length of the needles varied between 150 and 350 micrometers. The widest dimension of the needle at its base was 250 μm. Preliminary application tests of the needle arrays show that they are robust and permit skin penetration without breakage. Transdermal water loss measurements before and after microneedle skin penetration are reported. Drug delivery is increased approximately by a factor of 750 in microneedle patch applications with respect to diffusion alone. The feasibility of using the microneedle array as a blood sampler on a capillary electrophoresis chip is demonstrated.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Cites
Microfabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., et al. (1990) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.576520 · Cited by 749 · see citing works
Lack of Pain Associated with Microfabricated Microneedles
Kaushik, S., Hord, A. H., Denson, D. D., McAllister, D. V., Smitra, S., Allen, M. G., & Prausnitz, M. R. (2001) · Anesthesia & Analgesia · doi:10.1213/00000539-200102000-00041 · Cited by 578 · see citing works
Measurement of water exchange through skin
Nilsson, G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441040 · Cited by 450 · see citing works
A multichannel neural probe for selective chemical delivery at the cellular level
Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605435 · Cited by 285 · see citing works
de Boer, M. J., Gardeniers, H. J. G. E., Jansen, H. V., et al. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.800928 · Cited by 266 · see citing works
Self-citationSilicon-processed microneedles
Lin, L., & Pisano, A. P. (1999) · Journal of Microelectromechanical Systems · doi:10.1109/84.749406 · Cited by 250 · see citing works
Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
Griss, P., & Stemme, G. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.809959 · Cited by 233 · see citing works
Micromachining of buried micro channels in silicon
de Boer, M. J., Tjerkstra, R. W., Berenschot, E., et al. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825783 · Cited by 187 · see citing works
Self-citationMicrofabricated Polysilicon Microneedles for Minimally Invasive Biomedical Devices
Zahn, J. D., Talbot, N. H., Liepmann, D., & Pisano, A. P. (2000) · Biomedical Microdevices · doi:10.1023/a:1009907306184 · Cited by 175 · see citing works
Gardeniers, H. J. G. E., Tilmans, H. A. C., & Visser, C. C. G. (1996) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.580239 · Cited by 171 · see citing works
Self-citationMicromachined needles for the transdermal delivery of drugs
Henry, S., McAllister, D. V., Allen, M. G., et al. (2002) · doi:10.1109/memsys.1998.659807 · Cited by 116 · see citing works
Fabrication of a micro needle for a trace blood test
Oka, K., Aoyagi, S., Arai, Y., Isono, Y., Hashiguchi, G., & Fujita, H. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00872-x · Cited by 115 · see citing works
Vrouwe, E. X., Lüttge, R., & van den Berg, A. (2004) · Electrophoresis · doi:10.1002/elps.200405885 · Cited by 79 · see citing works
Rat percutaneous transport of diclofenac and influence of hydrogenated soya phospholipids.
Nishihata, T., KOTERA, K., NAKANO, Y., et al. (1987) · Chemical and Pharmaceutical Bulletin · doi:10.1248/cpb.35.3807 · Cited by 77 · see citing works
In Vivo Bioavailability and Metabolism of Topical Diclofenac Lotion in Human Volunteers
Hui, X., Hewitt, P. G., Poblete, N., et al. (1998) · Pharmaceutical Research · doi:10.1023/a:1011911302005 · Cited by 64 · see citing works
Nijdam, A. J., van Veenendaal, E., Cuppen, H. M., et al. (2001) · Journal of Applied Physics · doi:10.1063/1.1352557 · Cited by 64 · see citing works
Silicon micromachined hollow microneedles for transdermal liquid transfer
Gardeniers, H. J. G. E., Berenschot, E., de Boer, M. J., et al. (2003) · doi:10.1109/memsys.2002.984224 · Cited by 59 · see citing works
Self-citationMicromachined needle arrays for drug delivery or fluid extraction
Brazzle, J. D., Papautsky, I., & Frazier, A. B. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.805145 · Cited by 56 · see citing works
Comparative metrology of the evaporimeter and the DermaLab® TEWL probe
Grove, G. L., Grove, M. J., Zerweck, C. R., et al. (1999) · Skin Research and Technology · doi:10.1111/j.1600-0846.1999.tb00196.x · Cited by 51 · see citing works
Computerized evaporimetry using the DermaLab® TEWL probe
Grove, G. L., Grove, M. J., Zerweck, C. R., et al. (1999) · Skin Research and Technology · doi:10.1111/j.1600-0846.1999.tb00197.x · Cited by 40 · see citing works
Chun, K., Hashiguchi, G., Toshiyoshi, H., et al. (1999) · doi:10.1109/memsys.1999.746863 · Cited by 36 · see citing works
Hollow Metallic Micromachined Needle Arrays
Brazzle, J. D., Papautsky, I., & Frazier, A. B. (2000) · Biomedical Microdevices · doi:10.1023/a:1009980412628 · Cited by 35 · see citing works
Two-Dimensional Arrays of Out-of-Plane Needles
Stoeber, B., & Liepmann, D. (2000) · doi:10.1115/imece2000-1116 · Cited by 28 · see citing works
A MULTICHANNEL NEURAL PROBE FOR SELECTRIVE CHEMICAL DELIVERY AT THE CELLULAR LEVEL
Chen, J. K., & Wise, K. D. (1994) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh1994.58 · Cited by 21 · see citing works
A three-dimensional neural recording array
Hoogerwerf, A. C., & Wise, K. D. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1991.148816 · Cited by 17 · see citing works
Microfabricated microdialysis microneedles for continuous medical monitoring
Zahn, J. D., Trebotich, D., & Liepmann, D. (2002) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893809 · Cited by 17 · see citing works
Nijdam, A. J., Gardeniers, H. J. G. E., Berenschot, E., et al. (2001) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/11/5/308 · Cited by 15 · see citing works
Self-citationFabrication of a Micro Needle for a Trace Blood Test
Oka, K., Aoyagi, S., Isono, Y., et al. (2001) · Springer eBooks · doi:10.1007/978-3-642-59497-7_98 · Cited by 14 · see citing works
A Monte Carlo study of etching in the presence of a mask junction
van Veenendaal, E., Cuppen, H. M., van Enckevort, W. J. P., et al. (2001) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/11/4/322 · Cited by 8 · see citing works
Measuring Lithium in Whole Blood Using Capillary Electrophoresis
Vrouwe, E. X., Lüttge, R., & van den Berg, A. (2002) · Springer eBooks · doi:10.1007/978-94-010-0295-0_59 · Cited by 3 · see citing works
Destacking loading conditions on a CE chip for measuring samples with a high matrix concentration
Vrouwe, E. X., & van den Berg, A. (2003) · University of Twente Research Information · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Suprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330 · see citing works
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310 · see citing works
Gill, H. S., & Prausnitz, M. R. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100517 · Cited by 164 · see citing works
Xiang, Z., Liu, J., & Lee, C. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.12 · Cited by 100 · see citing works
Varying-Length Polymer Microneedle Arrays Fabricated by Droplet Backside Exposure
Kwon, K. Y., Weber, A., & Li, W. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2352412 · Cited by 23 · see citing works
- Authors
- Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A.
- Affiliations
- University of Twente (NL)
- Google (Israel) (IL)
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2003-12
- Volume
- 12
- Issue
- 6
- Pages
- 855-862
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2533221106
- Cited by
- 413
- References
- 31
- Citations by year
- 2026: 8 · 2025: 14 · 2024: 13 · 2023: 19 · 2022: 13 · 2021: 17 · 2020: 21 · 2019: 22 · 2018: 17 · 2017: 16 · 2016: 17 · 2015: 22 · 2014: 18 · 2013: 24 · 2012: 20
- FWCI
- 13.85
- Type
- journal article
- Language
- en
- Open access
- green
- research.utwente.nl
- Locations
- Journal of Microelectromechanical Systems (publishedVersion)
- TU/e Research Portal (publishedVersion)
- TU/e Research Portal (submittedVersion)
- University of Twente Research Information (submittedVersion)
- University of Twente Research Information (submittedVersion, other-oa)
- Funders
- University of Twente
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- hollow microneedles, silicon micromachining, transdermal drug delivery, deep reactive ion etching, anisotropic wet etching, microneedle arrays, skin penetration, transepidermal water loss, microneedle patch
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review