Implantable multichannel electrode array based on soi technology
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This work presents a new method of fabricating implantable multielectrode arrays on lightly doped single-crystal silicon. Such arrays are essential tools for electrical stimulation and recording of nerve signals. Our new microfabrication process, based on silicon-on-insulator (SOI) technology, inherently has excellent control over the final probe thickness without wet etching. The needle shanks are 6 mm long and 80 μm wide. Here the thickness of the probe, 25 μm, is defined by the device layer thickness on the SOI wafer. Our new sprinkler fluidic channel, which has holes spaced 50 μm apart along its 6 mm length, permits the perfusion of a large area of tissue with any desired neurotransmitter or other drug. The probes fabricated here are tested in the cat primary visual cortex; data recorded from adjacent neurons was used to characterize their orientation tuning. The sprinkler channel was characterized, and flowrate through the channel is a linear function of the applied pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Nanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K., Donoghue, J. P., Fraser, S. E., Lippincott-Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 356
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, J., Blanche, T. J., Harrison, R. R., Lester, H. A., & Masmanidis, S. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026204 · Cited by 231
“Deep reactive ion etching was used to release the probes from the SOI substrate (Figure 2F) [15,21].”
Method
Metadata
- Authors
- Cheung, K. C., Djupsund, K., Dan, Y., & Lee, L. P.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2003-04
- Volume
- 12
- Issue
- 2
- Pages
- 179-184
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2140211951
- Cited by
- 81
- References
- 1
- FWCI
- 0.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.