CoChat

Implantable multichannel electrode array based on soi technology

Cheung, K.C., Djupsund, K., Dan, Y., Lee, L.P. · 2003 · Journal of Microelectromechanical Systems
Cited by 81

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This work presents a new method of fabricating implantable multielectrode arrays on lightly doped single-crystal silicon. Such arrays are essential tools for electrical stimulation and recording of nerve signals. Our new microfabrication process, based on silicon-on-insulator (SOI) technology, inherently has excellent control over the final probe thickness without wet etching. The needle shanks are 6 mm long and 80 μm wide. Here the thickness of the probe, 25 μm, is defined by the device layer thickness on the SOI wafer. Our new sprinkler fluidic channel, which has holes spaced 50 μm apart along its 6 mm length, permits the perfusion of a large area of tissue with any desired neurotransmitter or other drug. The probes fabricated here are tested in the cat primary visual cortex; data recorded from adjacent neurons was used to characterize their orientation tuning. The sprinkler channel was characterized, and flowrate through the channel is a linear function of the applied pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jmems.2003.809962

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 81

Metadata

Authors
Cheung, K. C., Djupsund, K., Dan, Y., & Lee, L. P.
Venue
Journal of Microelectromechanical Systems
Published
2003-04
Volume
12
Issue
2
Pages
179-184
ISSN
1057-7157 (ISSN-L)
OpenAlex
W2140211951
Cited by
81
References
1
FWCI
0.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.