Fabrication of Flexible Neural Probes With Built-In Microfluidic Channels by Thermal Bonding of Parylene
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes the fabrication technology and characterization of Parylene neural probes containing fluidic channels for delivery of small amounts of drugs into biological tissue as well as neural recording. We present a first attempt to realize such neural probes by micromolding and thermal bonding of Parylene. Compared to the common fabrication method, where a sacrificial photoresist layer is sandwiched between two Parylene layers, the major advantages of this process are, that the time consuming photoresist dissolution is omitted, and that the adhesion between the Parylene layers could be improved. The electrodes were characterized by impedance measurements, in which an impedance sufficiently low for neural recording was observed. Fluidic injection experiments with the microchannel have shown that nanoliter volumes can be injected
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metz, S., Bertsch, A., Bertrand, D., & Renaud, P. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.11.021 · Cited by 167 · cited 2×
“This allows us to dry etch the bonded Parylene layers without risk of peeling off and the final devices can easily be released from the mold by anodic dissolution of the aluminum in a sodium chloride solution [17], [18].”
BackgroundMethod
Cited by
A practical guide for the fabrication of microfluidic devices using glass and silicon
Iliescu, C., Taylor, H., Avram, M., Miao, J., & Franssila, S. (2012) · Biomicrofluidics · doi:10.1063/1.3689939 · Cited by 385
Flexible Microfluidics: Fundamentals, Recent Developments, and Applications
Fallahi, H., Zhang, J., Phan, H.-P., & Nguyen, N.-T. (2019) · Micromachines · doi:10.3390/mi10120830 · Cited by 224
“Flexible microfluidic platforms fabricated using PI, parylene, PDMS, and SU-8 have been utilized in the production of soft eural probes to overcome the drawbacks of the hard probes [86,87,98,189,190].”
BackgroundA review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Micromachining of Parylene C for bioMEMS
Kim, B. J., & Meng, E. (2016) · Polymers for Advanced Technologies · doi:10.1002/pat.3729 · Cited by 204
Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J., & Meng, E. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 184
“Additionally, molds for materials that are deposited by means of CVD are difficult to separate, and may require the use of adhesion-promoting or adhesion-demoting techniques to [67] help decouple the mold from the substrate.”
BackgroundMethod
Metadata
- Authors
- Ziegler, D., Suzuki, T., & Takeuchi, S.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2006-12
- Volume
- 15
- Issue
- 6
- Pages
- 1477-1482
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2110237947
- Cited by
- 117
- References
- 1
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.