Micromachining of Parylene C for bioMEMS
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Recent advances in the micromachining of poly(p-xylylenes), commercially known as Parylenes, have enabled the development of novel structures and devices for microelectromechanical systems (MEMS). In particular, Parylene C (poly[chloro-p-xylylene]) has been explored extensively for biomedical applications of MEMS given its compatibility with micromachining processes, proven biocompatibility, and many advantageous properties including its chemical inertness, optical transparency, flexibility, and mechanical strength. Here we present a review of often used and recently developed micromachining process for Parylene C, as well as a high-level overview of state-of-the-art Parylene hybrid and free film devices for biomedical MEMS (bioMEMS) applications, including a discussion on its challenges and potential as a MEMS material. Copyright © 2015 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell and protein compatibility of parylene-C surfaces
Chang, T. Y., Yadav, V. G., De Leo, S., Mohedas, A., Rajalingam, B., Chen, C.-L., Selvarasah, S., Dokmeci, M. R., & Khademhosseini, A. (2007) · Langmuir · doi:10.1021/la7017049 · Cited by 320
The insulation performance of reactive parylene films in implantable electronic devices
Seymour, J. P., Elkasabi, Y. M., Chen, H.-Y., Lahann, J., & Kipke, D. R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.061 · Cited by 147
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices
Vanhoestenberghe, A., & Donaldson, N. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/031002 · Cited by 140
Novel multi-sided, microelectrode arrays for implantable neural applications
Seymour, J. P., Langhals, N. B., Anderson, D. J., & Kipke, D. R. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9512-z · Cited by 95
A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2333733 · Cited by 56
Byun, D., Cho, S. J., & Kim, S. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/12/125010 · Cited by 39
Sharma, A., Rieth, L., Tathireddy, P., Harrison, R., Oppermann, H., Klein, M., Töpper, M., Jung, E., Normann, R., Clark, G., et al. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2011.11.015 · Cited by 35
Cited by
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Recording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Byun, D., Cho, S.-J., Lee, B. H., Min, J., Lee, J.-H., & Kim, S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7493 · Cited by 23
Metadata
- Authors
- Kim, B. J., & Meng, E.
- Venue
- Polymers for Advanced Technologies
- Publisher
- Wiley
- Published
- 2015-12-15
- Volume
- 27
- Issue
- 5
- Pages
- 564-576
- ISSN
- 1042-7147 (ISSN-L)
- OpenAlex
- W2289031597
- Cited by
- 204
- References
- 7
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micromachining of Parylene C for bioMEMS. https://app.cochat.ai/papers/10.1002/pat.3729
- The paper
- Kim, B. J., & Meng, E. (2016). Micromachining of Parylene C for bioMEMS. Polymers for Advanced Technologies. https://doi.org/10.1002/pat.3729
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.