The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Flexible Dome and Bump Shape Piezoelectric Tactile Sensors Using PVDF-TrFE Copolymer
Abstract
In this paper, a new mold-transfer method to pattern piezoelectric polymer has been developed and applied to fabricate innovative dome and bump shape polyvinylidene-fluoride-trifluoroethylene (PVDF-TrFE) films. The dome and bump shape PVDF-TrFE films have been successfully fabricated and characterized as a sensing component for flexible tactile sensors. The tactile sensors developed using these polymer microstructures show a high sensitivity which can measure as small as 40 mN force for bump shape sensors and 25 mN for dome shape sensors. The newly developed fabrication method provides a flexible way to pattern the piezoelectric polymer with different shapes and dimensions, including bump and dome shape piezoelectric polymer microstructures. In addition, a selective dc poling method for the PVDF-TrFE film has been developed for fabricating precisely located piezoelectric sensors with minimum crosstalk. The bump and dome shape PVDF-TrFE films developed in this paper can have numerous applications for microcatheters or other minimally invasive biomedical devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We use P(VDF-TrFE) as flexible piezoelectric materials with high mechanical strength and biocompatibility43.”
From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [43]
Citations
Cites
Ferroelectric properties of vinylidene fluoride copolymers
Furukawa, T. (1989) · Phase Transitions · doi:10.1080/01411598908206863 · Cited by 1,167
Nalwa, H. S. (1995) · CRC Press eBooks · doi:10.1201/9781482295450 · Cited by 1,130
Gautschi, G. H. (2002) · Springer eBooks · doi:10.1007/978-3-662-04732-3 · Cited by 271
Dargahi, J., Parameswaran, M. A., & Payandeh, S. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.870059 · Cited by 211
Ferroelectric-to-paraelectric phase transition of vinylidene fluoride-trifluoroethylene copolymer
Yamada, T., Ueda, T., & Kitayama, T. (1981) · Journal of Applied Physics · doi:10.1063/1.328783 · Cited by 194
Micropatterning of semicrystalline poly(vinylidene fluoride) (PVDF) solutions
Park, Y. J., Kang, Y. S., & Park, C. (2005) · European Polymer Journal · doi:10.1016/j.eurpolymj.2004.11.022 · Cited by 187
Biomedical Microsystems for Minimally Invasive Diagnosis and Treatment
Haga, Y., & Esashi, M. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820545 · Cited by 113
Xia, F., Razavi, B., Xu, H., Cheng, Z. ‐., & Zhang, Q. (2002) · Journal of Applied Physics · doi:10.1063/1.1503395 · Cited by 80
Flexible biosensors on spirally rolled micro tube for cardiovascular in vivo monitoring
Li, C., Han, J., & Ahn, C. H. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.08.043 · Cited by 79
Self-citationPiezoelectric Polymers–Materials and Manufacture
Ohigashi, H. (1985) · Japanese Journal of Applied Physics · doi:10.7567/jjaps.24s2.23 · Cited by 70
Design, fabrication and testing of piezoelectric polymer PVDF microactuators
Fu, Y., Harvey, E. C., Ghantasala, M. K., & Spinks, G. M. (2005) · Smart Materials and Structures · doi:10.1088/0964-1726/15/1/023 · Cited by 68
Robert, M., Molingou, G., Snook, K. A., Cannata, J. M., & Shung, K. K. (2004) · Journal of Applied Physics · doi:10.1063/1.1760233 · Cited by 54
Dargahi, J., & Najarian, S. (2004) · Sensor Review · doi:10.1108/02602280410515851 · Cited by 48
Design and microfabrication of a hybrid piezoelectric‐capacitive tactile sensor
Dargahi, J., Kahrizi, M., Rao, N. P., & Sokhanvar, S. (2006) · Sensor Review · doi:10.1108/02602280610675465 · Cited by 40
Miniature high frequency focused ultrasonic transducers for minimally invasive imaging procedures
Fleischman, A. J., Modi, R., Nair, A., Talman, J. R., Lockwood, G., & Roy, S. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(02)00323-0 · Cited by 40
LIPP investigation of piezoelectricity distributions in PVDF poled with various methods
Sessler, G. M., & Berraissoul, A. (1987) · Ferroelectrics · doi:10.1080/00150198708016971 · Cited by 27
Transfer by direct photo etching of poly(vinylidene flouride) using X-rays
Manohara, M., Morikawa, E., Choi, J., & Sprunger, P. T. (1999) · Journal of Microelectromechanical Systems · doi:10.1109/84.809056 · Cited by 23
TANAKA, M., MIYATA, K., Nishizawa, T., & CHONAN, S. (2005) · Smart Materials and Structures · doi:10.1088/0964-1726/14/4/004 · Cited by 22
High-throughput plastic microlenses fabricated using microinjection molding techniques
Appasamy, S., Li, W., Lee, S. H., Boyd, J. T., & Ahn, C. H. (2005) · Optical Engineering · doi:10.1117/1.2149350 · Cited by 22
Self-citationLesser-known piezoelectric and pyroelectric applications of electroactive polymers
Lang, S. B., & Muensit, S. (2005) · MRS Proceedings · doi:10.1557/proc-0889-w01-01 · Cited by 12
Li, C., Lee, S., Gorton, A., Schulz, M. J., & Ahn, C. H. (2007) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2007.4433104 · Cited by 6
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- li, 2006, temperature, flow and glucose sensors integrated with a spirally-rolled polymer tube for cardiovascular monitoring, Proc TAS, 2, 1546
Cited by
Sorted by citations
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
A review of piezoelectric polymers as functional materials for electromechanical transducers
Ramadan, K., Sameoto, D., & Evoy, S. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/3/033001 · Cited by 1,062
Piezoelectric Biomaterials for Sensors and Actuators
Chorsi, M. T., Curry, E. J., Chorsi, H. T., Das, R., Baroody, J., Purohit, P. K., Ilieş, H., & Nguyen, T. D. (2018) · Advanced Materials · doi:10.1002/adma.201802084 · Cited by 879
A review of tactile sensing technologies with applications in biomedical engineering
Tiwana, M. I., Redmond, S. J., & Lovell, N. H. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2012.02.051 · Cited by 743
Mahapatra, S. D., Mohapatra, P. C., Aria, A. I., Christie, G., Mishra, Y. K., Hofmann, S., & Thakur, V. K. (2021) · Advanced Science · doi:10.1002/advs.202100864 · Cited by 661
Metadata
- Authors
- Li, C., Wu, P.-M., Lee, S., Gorton, A., Schulz, M. J., & Ahn, C. H.
- Affiliations
- University of Cincinnati (US)
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2008-04
- Volume
- 17
- Issue
- 2
- Pages
- 334-341
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2158076978
- Cited by
- 245
- References
- 21
- Citations by year
- 2026: 7 · 2025: 11 · 2024: 6 · 2023: 16 · 2022: 19 · 2021: 21 · 2020: 27 · 2019: 21 · 2018: 16 · 2017: 19 · 2016: 10 · 2015: 16 · 2014: 16 · 2013: 9 · 2012: 12
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Microelectromechanical Systems (publishedVersion)
- Funders
- University of Cincinnati
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Dielectric materials and actuators
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- piezoelectric tactile sensor, flexible sensors, microcatheter, crosstalk reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review