The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Planar Microassembly by Parallel Actuation of MEMS Microrobots
Abstract
We present designs, theory, and results of fabrication and testing for a novel parallel microrobotic assembly scheme using stress-engineered MEMS microrobots. The robots are 240-280 mum times 60 mum times 7-20 mum in size and can be controlled to dock compliantly together, forming planar structures several times this size. The devices are classified into species based on the design of their steering arm actuators, and the species are further classified asindependentif they can be maneuvered independently using a single global control signal. In this paper, we show that microrobot species are independent if the two transition voltages of their steering arms, i.e., the voltages at which the arms are raised or lowered, form a unique pair. We present control algorithms that can be applied to groups of independent microrobot species to direct their motion from arbitrary nondead-lock configurations to desired planar microassemblies. We present designs and fabrication for four independent microrobot species, each with a unique transition voltage. The fabricated microrobots are used to demonstrate directed assembly of five types of planar structures from two classes of initial conditions. We demonstrate an average docking accuracy of 5 mum and use self-aligning compliant interaction between the microrobots to further align and stabilize the intermediate assemblies. The final assemblies match their target shapes on average 96%, by area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coordination of groups of mobile autonomous agents using nearest neighbor rules
Jadbabaie, A., Lin, J., & Morse, A. S. (2003) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2003.812781 · Cited by 8,339
Design and self-assembly of two-dimensional DNA crystals
Winfree, E., Liu, F., Wenzler, L. A., & Seeman, N. C. (1998) · Nature · doi:10.1038/28998 · Cited by 2,857
Cited by
Biomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Modeling and Experimental Characterization of an Untethered Magnetic Micro-Robot
Pawashe, C., Floyd, S., & Sitti, M. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909341413 · Cited by 318
Parker, L. E., Rus, D., & Sukhatme, G. S. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_53 · Cited by 290
Independent control of multiple magnetic microrobots in three dimensions
Diller, E., Giltinan, J., & Sitti, M. (2013) · The International Journal of Robotics Research · doi:10.1177/0278364913483183 · Cited by 267
Metadata
- Authors
- Donald, B. R., Levey, C. G., & Paprotny, I.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2008-08
- Volume
- 17
- Issue
- 4
- Pages
- 789-808
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2168587747
- Cited by
- 160
- References
- 2
- FWCI
- 12.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Planar Microassembly by Parallel Actuation of MEMS Microrobots. https://app.cochat.ai/papers/10.1109/jmems.2008.924251
- The paper
- Donald, B. R., Levey, C. G., & Paprotny, I. (2008). Planar Microassembly by Parallel Actuation of MEMS Microrobots. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2008.924251
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.