The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant
Abstract
This paper presents an implant-based wireless pressure sensing paradigm for long-range continuous intraocular pressure (IOP) monitoring of glaucoma patients. An implantable parylene-based pressure sensor has been developed, featuring an electrical LC-tank resonant circuit for passive wireless sensing without power consumption on the implanted site. The sensor is microfabricated with the use of parylene C (poly-chloro-p-xylylene) to create a flexible coil substrate that can be folded for smaller physical form factor so as to achieve minimally invasive implantation, while stretched back without damage for enhanced inductive sensor-reader coil coupling so as to achieve strong sensing signal. A data-processed external readout method has also been developed to support pressure measurements. By incorporating the LC sensor and the readout method, wireless pressure sensing with 1-mmHg resolution in longer than 2-cm distance is successfully demonstrated. Other than extensive on-bench characterization, device testing through six-month chronic in vivo and acute ex vivo animal studies has verified the feasibility and efficacy of the sensor implant in the surgical aspect, including robust fixation and long-term biocompatibility in the intraocular environment. With meeting specifications of practical wireless pressure sensing and further reader development, this sensing methodology is promising for continuous, convenient, direct, and faithful IOP monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P., & Woinowsky-Krieger, S. (1959) · UCLA Biblioteca de Ingenieria Civil · Cited by 12,112
The Design of CMOS Radio-Frequency Integrated Circuits
Lee, T. H. (2003) · Cambridge University Press eBooks · doi:10.1017/cbo9780511817281 · Cited by 3,497
Roark's Formulas for Stress and Strain
Roark, R. J., & Young, W. C. (1938) · Cited by 3,020
Field and wave electromagnetics
Cheng, D. K. (1983) · Cited by 2,199
Terman, F. E. (1943) · Virtual Defense Library (Ministerio de Defensa) · Cited by 1,017
Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S., & Lindenmuth, K. (2000) · Journal of Glaucoma · doi:10.1097/00061198-200004000-00002 · Cited by 901
The design of CMOS radio-frequency integrated circuits, 2nd edition
Lee, T. H. (2004) · Communications Engineer · Cited by 484
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
Wireless micromachined ceramic pressure sensor for high-temperature applications
Fonseca, M. A., English, J. M., von Arx, M., & Allen, M. G. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.800939 · Cited by 320
Ocular Rigidity in Living Human Eyes
Pallikaris, I. G., Kymionis, G. D., Ginis, H. S., Kounis, G. A., & Tsilimbaris, M. K. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0162 · Cited by 301
Ocular Biomechanics and Biotransport
Ethier, C. R., Johnson, M., & Ruberti, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140055 · Cited by 288
Miniature Passive Pressure Transensor for Implanting in the Eye
Collins, C. C. (1967) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1967.4502474 · Cited by 282
A wireless batch sealed absolute capacitive pressure sensor
Akar, O., Akin, T., & Najafi, K. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00753-1 · Cited by 258
Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors
Chen, P.-J., Rodger, D. C., Saati, S., Humayun, M. S., & Tai, Y.-C. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.2004945 · Cited by 251
Self-citation24-Hour Monitoring of Intraocular Pressure in Glaucoma Management: A Retrospective Review
Hughes, E., Spry, P., & Diamond, J. (2003) · Journal of Glaucoma · doi:10.1097/00061198-200306000-00009 · Cited by 241
24-hour monitoring of intraocular pressure in glaucoma management: a retrospective review
Hughes, E., Spry, P., & Diamond, J. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.10.008 · Cited by 216
Design and application of a wireless, passive, resonant-circuit environmental monitoring sensor
Ong, K. G., Grimes, C. A., Robbins, C. L., & Singh, R. S. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00624-0 · Cited by 196
FLEXIBLE WIRELESS PASSIVE PRESSURE SENSORS FOR BIOMEDICAL APPLICATIONS
Fonseca, M. A., Allen, M. G., Kroh, J., & White, J. (2006) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2006.9 · Cited by 113
Continuous measurement of intraocular pressure in rabbits by telemetry.
McLaren, J. W., Brubaker, R. F., & FitzSimon, J. S. (1996) · PubMed · Cited by 111
Intraocular Pressure Monitoring Sensors
Katuri, K. C., Asrani, S., & Ramasubramanian, M. K. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912539 · Cited by 108
Wang, X.-Q., Lin, Q., & Tai, Y. (1999) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1999.746801 · Cited by 107
Self-citationA double-sided single-chip wireless pressure sensor
DEHENNIS, A. D., & Wise, K. D. (2003) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2002.984250 · Cited by 95
Mutual inductance of air-cored coils: Effect on design of radio-frequency coupled implants
Flack, F. C., James, E. D., & Schlapp, D. M. (1971) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474736 · Cited by 91
Medical implants based on microsystems
Mokwa, W. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/5/r01 · Cited by 69
A system for passive implantable pressure sensors
Rosengren, L., Rangsten, P., Bäcklund, Y., Hök, B., Svedbergh, B., & Selén, G. (1994) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(93)00664-p · Cited by 52
Cited by
Piezoelectric Biomaterials for Sensors and Actuators
Chorsi, M. T., Curry, E. J., Chorsi, H. T., Das, R., Baroody, J., Purohit, P. K., Ilies, H., & Nguyen, T. D. (2019) · Advanced Materials · doi:10.1002/adma.201802084 · Cited by 865
Chen, L. Y., Tee, B. C. K., Chortos, A. L., Schwartz, G., Tse, V., J. Lipomi, D., Wong, H. S. P., McConnell, M. V., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms6028 · Cited by 541
Flexible Transparent Iontronic Film for Interfacial Capacitive Pressure Sensing
Nie, B., Li, R., Cao, J., Brandt, J. D., & Pan, T. (2015) · Advanced Materials · doi:10.1002/adma.201502556 · Cited by 463
First Decade of Interfacial Iontronic Sensing: From Droplet Sensors to Artificial Skins
Chang, Y., Wang, L., Li, R., Zhang, Z., Wang, Q., Yang, J., Guo, C. F., & Pan, T. (2021) · Advanced Materials · doi:10.1002/adma.202003464 · Cited by 381
Materials and Designs for Wireless Epidermal Sensors of Hydration and Strain
Huang, X., Liu, Y., Cheng, H., Shin, W., Fan, J. A., Liu, Z., Lu, C., Kong, G., Chen, K., Patnaik, D., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303886 · Cited by 302
Metadata
- Authors
- Chen, P.-J., Saati, S., Varma, R., Humayun, M. S., & Tai, Y.-C.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2010-08
- Volume
- 19
- Issue
- 4
- Pages
- 721-734
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2154491554
- Cited by
- 264
- References
- 25
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.