A Piezoelectric Parametric Frequency Increased Generator for Harvesting Low-Frequency Vibrations
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents the design, fabrication, and testing of a piezoelectric parametric frequency increased generator for harvesting low-frequency non-periodic vibrations. The generator incorporates a bulk piezoelectric ceramic machined using ultrafast laser ablation. The electromechanical transducer is designed as a clamped-clamped spiral beam in order to decrease the stiffness within a limited footprint. An internal mechanism up-converts the ambient vibration frequency to a higher internal operation frequency in order to achieve better electromechanical coupling and efficiency. To gain maximum power output, the optimum width and thickness values of a spiral up-conversion unit are computed via multi-physics finite-element analysis simulations. The fabricated device generated a peak power of 100 μW and an average power of 3.25 μW from an input acceleration of 9.8 m/s2at 10 Hz. The device operates over a frequency range of 24 Hz. The internal volume of the generator is 1.2 cm3.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy harvesting vibration sources for microsystems applications
Beeby, S. P., Tudor, M. J., & White, N. M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/r01 · Cited by 3,008 · cited 1×
“and at high frequencies (> 30 Hz) [1], [2].”
BackgroundEnergy Harvesting From Human and Machine Motion for Wireless Electronic Devices
Mitcheson, P. D., Yeatman, E. M., Rao, G. K., Holmes, A. S., & Green, T. C. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.927494 · Cited by 1,888 · cited 2×
“The volume figure of merit (FoMv) and bandwidth figure of merit (FoMBW) are computed as defined in [2], with the exception that in this work, the 3 dB bandwidth is used for FoMBW (instead of 1 dB as originally defined) and the center frequency is taken to mean the lowest frequency of interest.”
BackgroundMethodElectromagnetic generator for harvesting energy from human motion
Saha, C. R., O’Donnell, T., Wang, N., & McCloskey, P. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.03.008 · Cited by 608
Cited by
Liu, H., Zhong, J., Lee, C., Lee, S.-W., & Lin, L. (2018) · Applied Physics Reviews · doi:10.1063/1.5074184 · Cited by 905
Safaei, M., Sodano, H. A., & Anton, S. R. (2019) · Smart Materials and Structures · doi:10.1088/1361-665x/ab36e4 · Cited by 874
“Reprinted, with permission, from [168]).”
Luo, A., Zhang, Y., Dai, X., Wang, Y., Xu, W., Lu, Y., Wang, M., Fan, K., & Wang, F. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115762 · Cited by 140
Design and Evaluation of Double-Stage Energy Harvesting Floor Tile
Isarakorn, D., Jayasvasti, S., Panthongsy, P., Janphuang, P., & Hamamoto, K. (2019) · Sustainability · doi:10.3390/su11205582 · Cited by 27
Metadata
- Authors
- Galchev, T., Aktakka, E. E., & Najafi, K.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2012-12
- Volume
- 21
- Issue
- 6
- Pages
- 1311-1320
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2001622952
- Cited by
- 109
- References
- 3
- FWCI
- 17.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.