The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Reducing Transient and Steady State Electricity Consumption in HVAC Using Learning-Based Model-Predictive Control
Abstract
Heating, ventilation, and air conditioning (HVAC) systems are an important target for efficiency improvements through new equipment and retrofitting because of their large energy footprint. One type of equipment that is common in homes and some offices is an electrical, single-stage heat pump air conditioner (AC). To study this setup, we have built the Berkeley Retrofitted and Inexpensive HVAC Testbed for Energy Efficiency (BRITE) platform. This platform allows us to actuate an AC unit that controls the room temperature of a computer laboratory on the Berkeley campus that is actively used by students, while sensors record room temperature and AC energy consumption. We build a mathematical model of the temperature dynamics of the room, and combining this model with statistical methods allows us to compute the heating load due to occupants and equipment using only a single temperature sensor. Next, we implement a control strategy that uses learning-based model-predictive control (MPC) to learn and compensate for the amount of heating due to occupancy as it varies throughout the day and year. Experiments on BRITE show that our techniques result in a 30%-70% reduction in energy consumption as compared to two-position control, while still maintaining a comfortable room temperature. The energy savings are due to our control scheme compensating for varying occupancy, while considering the transient and steady state electrical consumption of the AC. Our techniques can likely be generalized to other HVAC systems while still maintaining these energy saving features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Åström, K. J., & Wittenmark, B. (1989) · Cited by 5,020
Enhancing Sparsity by Reweighted ℓ 1 Minimization
Candès, E. J., Wakin, M. B., & Boyd, S. P. (2008) · Journal of Fourier Analysis and Applications · doi:10.1007/s00041-008-9045-x · Cited by 4,863
SNOPT: An SQP Algorithm for Large-Scale Constrained Optimization
Gill, P. E., Murray, W., & Saunders, M. A. (2005) · SIAM Review · doi:10.1137/s0036144504446096 · Cited by 2,834
EnergyPlus: creating a new-generation building energy simulation program
Crawley, D. B., Lawrie, L. K., Winkelmann, F. C., Buhl, W. F., Huang, Y. J., Pedersen, C. O., Strand, R. K., Liesen, R. J., Fisher, D. E., Witte, M. J., et al. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00114-6 · Cited by 2,822
Adaptive control stability, convergence, and robustness
Egardt, B. (1993) · Automatica · doi:10.1016/0005-1098(93)90081-4 · Cited by 2,712
Root-N-Consistent Semiparametric Regression
Robinson, P. M. (1988) · Econometrica · doi:10.2307/1912705 · Cited by 2,475
Adaptive Control: Stability, Convergence, and Robustness
Sastry, S., Bodson, M., & Bartram, J. F. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399905 · Cited by 2,167
Efficient and Adaptive Estimation for Semiparametric Models.
Do, K. A., Bickel, P. J., Klaassen, C. A. J., Ritov, Y., & Wellner, J. A. (1994) · Biometrics · doi:10.2307/2533465 · Cited by 1,403
Efficient and Adaptive Estimation for Semiparametric Models.
Schick, A., Bickel, P. J., Klaassen, C. A. J., Ritov, Y., & Wellner, J. A. (1994) · Journal of the American Statistical Association · doi:10.2307/2291028 · Cited by 1,109
Multi-Parametric Toolbox (MPT)
Kvasnica, M., Grieder, P., Baotić, M., & Morari, M. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-24743-2_30 · Cited by 986
EnergyPlus エネルギー・シミュレーション・プログラム
Crawley, D. B., Lawrie, L. K., PEDERSEN, C. O., & Winkelmann, F. C. (2000) · Cited by 725
Systems with persistent disturbances: predictive control with restricted constraints
Chisci, L., Rossiter, J. A., & Zappa, G. (2001) · Automatica · doi:10.1016/s0005-1098(01)00051-6 · Cited by 676
Robust model predictive control using tubes
Langson, W., Chryssochoos, I., Raković, S. V., & Mayne, D. Q. (2004) · Automatica · doi:10.1016/j.automatica.2003.08.009 · Cited by 672
Controllers for reachability specifications for hybrid systems
Lygeros, J., Tomlin, C., & Sastry, S. (1999) · Automatica · doi:10.1016/s0005-1098(98)00193-9 · Cited by 608
Self-citationAutonomous Helicopter Aerobatics through Apprenticeship Learning
Abbeel, P., Coates, A., & Ng, A. Y. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910371999 · Cited by 584
Provably safe and robust learning-based model predictive control
Aswani, A., Gonzalez, H., Sastry, S. S., & Tomlin, C. (2013) · Automatica · doi:10.1016/j.automatica.2013.02.003 · Cited by 539
Self-citationA game theoretic approach to controller design for hybrid systems
Tomlin, C. J., Lygeros, J., & Shankar Sastry, S. (2000) · Proceedings of the IEEE · doi:10.1109/5.871303 · Cited by 510
Self-citationOldewurtel, F., Parisio, A., Jones, C. N., Morari, M., Gyalistras, D., Gwerder, M., Stauch, V, Lehmann, B., & Wirth, K. (2010) · Proceedings of the 2010 American Control Conference · doi:10.1109/acc.2010.5530680 · Cited by 435
Dynamic programming for constrained optimal control of discrete-time linear hybrid systems
Borrelli, F., Baotić, M., Bemporad, A., & Morari, M. (2005) · Automatica · doi:10.1016/j.automatica.2005.04.017 · Cited by 354
Evaluation of optimal control for active and passive building thermal storage
Henze, G. P., Felsmann, C., & Knabe, G. (2004) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2003.06.001 · Cited by 328
Robust tube-based MPC for tracking of constrained linear systems with additive disturbances
Limón, D., Alvarado, I., Álamo, T., & Camacho, E. F. (2010) · Journal of Process Control · doi:10.1016/j.jprocont.2009.11.007 · Cited by 319
Examples when nonlinear model predictive control is nonrobust
Grimm, G., Messina, M. J., Tuna, S. E., & Teel, A. R. (2004) · Automatica · doi:10.1016/j.automatica.2004.04.014 · Cited by 240
sMAP: a simple measurement and actuation profile for physical information
Dawson-Haggerty, S., Jiang, X., Tolle, G., Ortiz, J., & Culler, D. (2010) · Proceedings of the 8th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/1869983.1870003 · Cited by 228
Self-citationA distributed predictive control approach to building temperature regulation
Ma, Y., Anderson, G., & Borrelli, F. (2011) · Proceedings of the 2011 American Control Conference · doi:10.1109/acc.2011.5991549 · Cited by 182
LQR-trees: Feedback motion planning on sparse randomized trees
Tedrake, R. (2009) · Robotics: Science and Systems · doi:10.15607/rss.2009.v.003 · Cited by 158
Building thermal model reduction via aggregation of states
Deng, K., Barooah, P., Mehta, P. G., & Meyn, S. (2010) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2010.5530470 · Cited by 136
An integrated approach to occupancy modeling and estimation in commercial buildings
Liao, C., & Barooah, P. (2010) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2010.5531035 · Cited by 108
Transient heat pump behaviour: a theoretical investigation
MacArthur, J. W. (1984) · International Journal of Refrigeration · doi:10.1016/0140-7007(84)90025-2 · Cited by 75
Regression on manifolds: Estimation of the exterior derivative
Aswani, A., Bickel, P., & Tomlin, C. J. (2010) · The Annals of Statistics · doi:10.1214/10-aos823 · Cited by 70
Self-citationREGRESSION ON MANIFOLDS: ESTIMATION OF THE EXTERIOR DERIVATIVE
Aswani, A. J., Bickel, P. J., & Tomlin, C. J. (2010) · Cited by 63
Self-citation
Cited by
Theory and applications of HVAC control systems – A review of model predictive control (MPC)
Afram, A., & Janabi-Sharifi, F. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.016 · Cited by 1,310
Learning-Based Model Predictive Control: Toward Safe Learning in Control
Hewing, L., Wabersich, K. P., Menner, M., & Zeilinger, M. N. (2020) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-090419-075625 · Cited by 835
State of the art in building modelling and energy performances prediction: A review
Foucquier, A., Robert, S., Suard, F., Stéphan, L., & Jay, A. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.004 · Cited by 832
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
Provably safe and robust learning-based model predictive control
Aswani, A., Gonzalez, H., Sastry, S. S., & Tomlin, C. (2013) · Automatica · doi:10.1016/j.automatica.2013.02.003 · Cited by 539
Self-citation
Metadata
- Authors
- Aswani, A., Master, N., Taneja, J., Culler, D., & Tomlin, C.
- Venue
- Proceedings of the IEEE
- Published
- 2012-01
- Volume
- 100
- Issue
- 1
- Pages
- 240-253
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W1968359621
- Cited by
- 289
- References
- 31
- FWCI
- 49.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.