Comments on Microelectrodes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Metal-filled microelectrodes are best for high-frequency work; fluid-filled ones are best for low frequencies and dc. Both have advantages and drawbacks. This paper gives the results of experience with both sorts of probe. Practical hints and recipes are included because these seldom appear in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The normal membrane potential of frog sartorius fibers
Ling, G., & Gerard, R. W. (1949) · Journal of Cellular and Comparative Physiology · doi:10.1002/jcp.1030340304 · Cited by 752
Dowben, R. M., & Rose, J. E. (1953) · Science · doi:10.1126/science.118.3053.22 · Cited by 196
Measurement of Bioelectric Potentials With Microelectrodes and Neutralized Input Capacity Amplifiers
Amatniek, E. (1958) · IRE Transactions on Medical Electronics · doi:10.1109/iret-me.1958.5008482 · Cited by 73
Cited by
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“Since the single extracellular microelectrodes used in the middle of the last century (Weale, 1951; Gesteland et al., 1959), development quickly proceeded to MEAs with multiple transducers for the purpose of increasing the number of neurons observed (Thomas et al., 1972; Gross et al., 1977; Pine,…”
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
“Recorded signals range from the noise level [2] (20 V or so) to about 1 mV, with an extracellular signal bandwidth of perhaps 10 kHz.”
BackgroundAn Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Recording action potentials from cultured neurons with extracellular microcircuit electrodes
Pine, J. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90042-4 · Cited by 543
AN ULTRASENSITIVE VIBRATING PROBE FOR MEASURING STEADY EXTRACELLULAR CURRENTS
Jaffe, L. F., & Nuccitelli, R. (1974) · The Journal of Cell Biology · doi:10.1083/jcb.63.2.614 · Cited by 525
Metadata
- Authors
- Gesteland, R. C., Howland, B., Lettvin, J. Y., & Pitts, W. H.
- Venue
- Proceedings of the IRE
- Published
- 1959-11
- Volume
- 47
- Issue
- 11
- Pages
- 1856-1862
- ISSN
- 0096-8390 (ISSN-L)
- 2162-6634
- OpenAlex
- W2039502538
- Cited by
- 301
- References
- 3
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.