Novel methods of faster cardiovascular diagnosis in wireless telecardiology
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
With the rapid development wireless technologies, mobile phones are gaining acceptance to become an effective tool for cardiovascular monitoring. However, existing technologies have limitations in terms of efficient transmission of compressed ECG over text messaging communications like SMS and MMS. In this paper, we first propose an ECG compression algorithm which allows lossless transmission of compressed ECG over bandwidth constrained wireless link. Then, we propose several algorithms for cardiovascular abnormality detection directly from the compressed ECG maintaining end to end security, patient privacy while offering the benefits of faster diagnosis. Next, we show that our mobile phone based cardiovascular monitoring solution is capable of harnessing up to 6.72 times faster diagnosis compared to existing technologies. As the decompression time on a doctor's mobile phone could be significant, our method will be highly advantageous in patient wellness monitoring system where a doctor has to read and diagnose from compressed ECGs of several patients assigned to him. Finally, we successfully implemented the prototype system by establishing mobile phone based cardiovascular patient monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079 · cited 2×
“After retrieval of RR signal, it is possible to deduce Heart Rate Variability (HRV), which is basically the rate of change of consecutive RR values [1], [21], [20].”
BackgroundMethodA comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 4×
“The Second Derivative Based Technique (SDBT) relies on similar mechanism used in QRS detection algorithms [24] based on Second Derivatives.”
MethodInfluential
Cited by
Smart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396
A comprehensive survey of wearable and wireless ECG monitoring systems for older adults
Baig, M. M., Gholamhosseini, H., & Connolly, M. J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1021-6 · Cited by 284
Pietroni, F., Casaccia, S., Revel, G. M., & Scalise, L. (2016) · 2016 IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2016.7479867 · Cited by 14
Metadata
- Authors
- Sufi, F., Fang, Q., Khalil, I., & Mahmoud, S. S.
- Venue
- IEEE Journal on Selected Areas in Communications
- Published
- 2009-05
- Volume
- 27
- Issue
- 4
- Pages
- 537-552
- ISSN
- 0733-8716 (ISSN-L)
- 1558-0008
- OpenAlex
- W2165177517
- Cited by
- 90
- References
- 2
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.