Dual-Mode Capacitive Proximity Sensor for Robot Application: Implementation of Tactile and Proximity Sensing Capability on a Single Polymer Platform Using Shared Electrodes
Abstract
In this paper, we report a flexible dual-mode capacitive sensor for robot applications which has two sensing capabilities in a single platform; tactile and proximity sensing capability. The sensor consists of a mechanical structure based on PDMS (Polydimethylsiloxane) and a mesh of multiple copper electrode strips. The mesh is composed of 16 top and 16 bottom copper strips crossed each other to form a 16 times 16 capacitor array. The proposed sensor is able to switch its function from tactile sensing to proximity sensing or vice versa by reconfiguring the connection of electrodes. The tactile sensing capability has been demonstrated already and reported in our previous paper (Lee et al.,, 2006); therefore, in this paper, we will demonstrate the feasibility of the proximity sensing capability and the dual-mode operation of the proposed sensor in detail. The capacitance change caused by an approaching object has been estimated through simulation of multiple two-dimensional models as an initial study. The measured data have shown similar trends with the simulation results. We tested various materials from conducting metals to a human hand for proximity measurement. The fabricated sensor could detect a human hand at a distance up to 17 cm away from the sensor. We also have successfully demonstrated the feasibility of dual-mode operation of the proposed sensor in real-time exploiting a custom designed PCB, a data acquisition pad, and Labview software.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018) · Nature Communications · doi:10.1038/s41467-017-02685-9 · Cited by 1,413
Tactile sensing for dexterous in-hand manipulation in robotics—A review
Yousef, H., Boukallel, M., & Althoefer, K. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.02.038 · Cited by 784
Flexible and Stretchable Capacitive Sensors with Different Microstructures
Qin, J., Yin, L., Hao, Y., Zhong, S., Zhang, D., Bi, K., Zhang, Y., Zhao, Y., & Dang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008267 · Cited by 616
A dual-mode soft gripper for food packaging
Wang, Z., Or, K., & Hirai, S. (2020) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2020.103427 · Cited by 222
Proximity Perception in Human-centered Robotics: A Survey on Sensing Systems and Applications
Navarro, S. E., Muhlbacher-Karrer, S., Alagi, H., Zangl, H., Koyama, K., Hein, B., Duriez, C., & Smith, J. R. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2021.3111786 · Cited by 162
Metadata
- Authors
- Lee, H.-K., Chang, S.-I., & Yoon, E.
- Venue
- IEEE Sensors Journal
- Published
- 2009-12
- Volume
- 9
- Issue
- 12
- Pages
- 1748-1755
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2133567427
- Cited by
- 210
- References
- 0
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-Mode Capacitive Proximity Sensor for Robot Application: Implementation of Tactile and Proximity Sensing Capability on a Single Polymer Platform Using Shared Electrodes. https://app.cochat.ai/papers/10.1109/jsen.2009.2030660
- The paper
- Lee, H.-K., Chang, S.-I., & Yoon, E. (2009). Dual-Mode Capacitive Proximity Sensor for Robot Application: Implementation of Tactile and Proximity Sensing Capability on a Single Polymer Platform Using Shared Electrodes. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2009.2030660
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).