In-Air Rangefinding With an AlN Piezoelectric Micromachined Ultrasound Transducer
Abstract
An ultrasonic rangefinder has a working range of 30 to 450 mm and operates at a 375-Hz maximum sampling rate. The random noise increases with distance and equals 1.3 mm at the maximum range. The range measurement principle is based on pulse-echo time-of-flight measurement using a single transducer for transmit and receive. The transducer consists of a piezoelectric AlN membrane with 400-μm diameter, which was fabricated using a low-temperature process compatible with processed CMOS wafers. The performance of the system exceeds the performance of other micromechanical rangefinders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrawide‐Bandgap Semiconductors: Research Opportunities and Challenges
Tsao, J. Y., Chowdhury, S., Hollis, M. A., Jena, D., Johnson, N. M., Jones, K. A., Kaplar, R. J., Rajan, S., Van de Walle, C. G., Bellotti, E., et al. (2018) · Advanced Electronic Materials · doi:10.1002/aelm.201600501 · Cited by 1,602
Review of piezoelectric micromachined ultrasonic transducers and their applications
Jung, J., Lee, W., Kang, W., Shin, E., Ryu, J., & Choi, H. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa851b · Cited by 340
Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158
Proto, A., Rufer, L., Basrour, S., & Penhaker, M. (2022) · Micromachines · doi:10.3390/mi13122127 · Cited by 23
Metadata
- Authors
- Przybyla, R. J., Shelton, S. E., Guedes, A., Izyumin, I. I., Kline, M. H., Horsley, D. A., & Boser, B. E.
- Venue
- IEEE Sensors Journal
- Published
- 2011-11
- Volume
- 11
- Issue
- 11
- Pages
- 2690-2697
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2145602502
- Cited by
- 198
- References
- 0
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.