Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Open accessAbstract
A major hurdle in brain-machine interfaces (BMI) is the lack of an implantable neural interface system that remains viable for a lifetime. This paper explores the fundamental system design trade-offs and ultimate size, power, and bandwidth scaling limits of neural recording systems built from low-power CMOS circuitry coupled with ultrasonic power delivery and backscatter communication. In particular, we propose an ultra-miniature as well as extremely compliant system that enables massive scaling in the number of neural recordings from the brain while providing a path towards truly chronic BMI. These goals are achieved via two fundamental technology innovations: 1) thousands of 10 - 100 μm scale, free-floating, independent sensor nodes, or neural dust, that detect and report local extracellular electrophysiological data, and 2) a sub-cranial interrogator that establishes power and communication links with the neural dust.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Neural dust technology currently employs thousands of independent free-floating 10-100 μm scale sensor nodes.
“This technology currently employs thousands of independent free-floating 10–100 μm scale sensor nodes referred to as “neural dust.””
From Human Brain/Cloud Interface (2019) · cites this paper as Seo et al., 2013
The System Concept (p. 1) describes neural dust as thousands of independent, free-floating 10–100 μm sensor nodes. But it says the authors “propose” this system; it does not establish that the technology currently employs those nodes. (LLM, conf=0.91)
Experimental — accuracy not yet measuredNeural dust power transmission is accomplished ultrasonically, enabling low-efficiency (7%, 11.6 dB) links, yielding ∼500 μW of received power with a 1 mm2 interrogator.
“Power transmission is accomplished ultrasonically to enable low-efficiency (7%, 11.6 dB) links, yielding ∼500 μW of received power (>107 higher than the ∼40 pW EM transmission available at a similar-size scale) with a 1 mm2 interrogator, which may eventually provide ∼10 μm sensing nodes.”
From Human Brain/Cloud Interface (2019) · cites this paper as Seo et al., 2013
The Power Delivery section (p. 5) models an ultrasonic link for a 100 µm node embedded 2 mm into the brain and reports 7% efficiency and approximately 500 µW received with a 1 mm² interrogator. It gives the link efficiency as −11.6 dB, not the claim’s positive 11.6 dB; these are modeled results, not a demonstrated transmission. (LLM, conf=0.88)
Experimental — accuracy not yet measuredEarly 'neural dust' proposals for providing BCI access to specific human-brain regions had several inherent limitations.
“Early “neural dust” proposals for providing BCI access to specific human–brain regions (e.g., neocortex) had several inherent limitations (Seo et al., 2013).”
From Human Brain/Cloud Interface (2019) · cites this paper as Seo et al., 2013
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · see citing works
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 1× · see citing works
“…the periphery (from which, increasingly, data is sent out wirelessly from a "hub") [1–4]; a practical upper bound of several hundred implantable recording sites [5–8]; and the development of a biological response around the implanted electrodes which degrades recording performance over time [9–12].”
BackgroundLee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220 · see citing works
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160 · see citing works
In vitro effects of ultrasound with different energies on the conduction properties of neural tissue
Tsui, P.-H., Wang, S.-H., & Huang, C.-C. (2005) · Ultrasonics · doi:10.1016/j.ultras.2004.12.003 · Cited by 149 · see citing works
Flagged first, then by citations
Research works printed but not linked: 44
- [14]Alivisatos AP, et al. (2013) Nanotools for neuroscience and brain activity mapping. ACS Nano 7(3):1850-66.
- [15]Press Release: whitehouse.gov/infographics/brain-initiative (2013)
- [19]Zamft BM, Marblestone AH, Kording K, Schmidt D, Martin-Alarcon D, Tyo K, Boyden ES, Church G (2012). Measuring Cation Dependent DNA Polymerase Fidelity Landscapes by Deep Sequencing. PLoS One 7(8):1-10.
- [23]Marblestone AH, Zamft BM, Maguire YG, Shapiro MG, Cybulski T, Glaser JI, Stranges PB, Kalhor R, Dalrymple DA, Seo D, Alon E, Maharbiz MM, Carmena JM, Rabaey JM, Boyden ES, Church GM, Kording KP (2013) Physical Principles for Scalable Neural Recording. arXiv:1306.5709 [q-bio.NC] . · arXiv
- [24]Muller R, Gambini S, Rabaey JM (2012) A 0.013 mm 2 5 µ WDC-coupled neural signal acquisition IC with 0.5 V supply. IEEE J Solid-State Circuits 47(1):232-43.
- [25]SeymourJP, Kipke DR (2006) Fabrication of polymer neural probes with sub-cellular features for reduced tissue encapsulation. IEEE EMBS Conf 4606-9.
- [27]Rabaey JM, et al. (2011) Powering and communicating with mm-size implants. IEEE DATE Conf 1-6.
- [28]Sodagar AM, Amiri P (2009) Capacitive coupling for power and data telemetry to implantable biomedical microsystems. IEEE EMBS Conf 411-4.
- [30]Yakovlev A, Kim S, Poon A (2012) Implantable biomedical devices: Wireless powering and communication. IEEE Comm Mag 50(4):152-9.
- [31]Clark GM (2003) Cochlear implants: fundamentals and applications. New York: Springer-Verlag .
- [32]IEEE (2006) C95.1-2005 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz.
- [33]Salim A, Baldi A, Ziaie B (2003) Inductive link modeling and design guidelines for optimum power transfer in implantable wireless microsystems. IEEE EMBS Conf 3368-71.
- [34]Fotopoulou K, Flynn BW (2011) Wireless power transfer in loosely coupled links: Coil misalignment model. IEEE Trans Magnetics 47(2):416-30.
- [35]Ishida K, et al. (2013) Insole Pedometer With Piezoelectric Energy Harvester and 2 V Organic Circuits. IEEE J Solid-State Circuits 48(1):255-64.
- [36]Wong SH, Kupnik M, Butts-Pauly K, Khuri-Yakub BT (2007) Advantages of Capacitive Micromachined Ultrasonics Transducers (CMUTs) for High Intensity Focused Ultrasound (HIFU). IEEE Ultrasonics Symp :1313-6.
- [37]Ozeri S, Shmilovitz D (2010) Ultrasonic transcutaneous energy transfer for powering implanted devices. Ultrasonics 50(6):556-66.
- [40]Hoskins PR, Martin K, Thrush A, editors (2010) Diagnostic Ultrasound: Physics and Equipment. New York: Cambridge University Press .
- [43]Tufail Y, Yoshihiro A, Pati S, Li MM, Tyler WJ (2011) Ultrasonic neuromodulation by brain stimulation with transcranial ultrasound. Nat Prot 6(9):1453-70.
- [44]King RL, Brown JR, Newsome WT, Butts-Pauly K (2012) Effective Parameters For Ultrasound-Induced In Vivo Neurostimulation. Ultrasound Med & Bio 39(2):312-31.
- [45]Foley JL, Little JW, Vaezy S (2007) Image-guided high-intensity focused ultrasound for conduction block of peripheral nerves. Annals Biomed Engineering 35(1):10919.
- [46]Krasovitski B, Frenkel V, Shoham S, Kimmel E (2011) Intramembrane cavitation as a unifying mechanism for ultrasound-induced bioeffects. Proc Natl Acad Sci 108(8):1-6.
- [47]Tyler WJ, Tufail Y, Finsterwald M, Tauchmann ML, Olson EJ, Majestic C (2008) Remote excitation of neuronal circuits using low-intensity, low-frequency ultrasound. PLoS One 3(10):1-11.
- [50]Zhou, Y. (2011). High intensity focused ultrasound in clinical tumor ablation. World J Clin Oncol 2(1):8-27.
- [51]Shung KK, Cannata JM, Zhou QF (2007) Piezoelectric materials for high frequency medical imaging applications: A review. J Electroceram 19:139-45.
- [52]Zenner HP, et al. (2000) Human studies of a piezoelectric transducer and a microphone for a totally implantable electronic hearing device. Am J Otol 21(2):196-204.
- [53]Maleki T, Cao N, Song S, Kao C, Ko SA, Ziaie B (2011) An ultrasonically powered implantable micro-oxygen generator (IMOG). IEEE Trans BioE 58(11):3104-11.
- [54]Przybyla RJ, Shelton SE, Guedes A, Izyumin II, Kline MH, Horsley DA, Boser BE (2011) In-air rangefinding with an aln piezoelectric micromachined ultrasound transducer. IEEE Sensors J 11(11):2690-7.
- [55]Krimholtz R, Leedom DA, Matthaei GA (1970) New equivalent circuits for elementary piezoelectric transducers. Electronics Lett 6(13):398-9.
- [56]Roa-Prada S, Scarton HA, Saulnier GJ, Shoudy DA, Ashdown JD, Das PK, Gavens AJ (2013) An Ultrasonic Through-Wall Communication (UTWC) System Model. J Vib Acoust 135(1):1-12.
- [57]Holland R (1968). Resonant properties of piezoelectric ceramic rectangular parallelepipeds. J Acoust Soc Am 43(5):988-97.
- [60]Mills DM, Smith SW (2002) Multi-layered PZT/polymer composites to increase signal-to-noise ratio and resolution for medical ultrasound transducers part II: Thick film technology. IEEE Ultrasonics 49(7):1005-14.
- [64]Belitski A, et al. (2008) Low-frequency local field potentials and spikes in primary visual cortex convey independent visual information. J Neurosci 28(22):5696-709.
- [66]Du J, Blanche TJ, Harrison RR, Lester HA, Masmanidis SC (2011) Multiplexed, high density electrophysiology with nanofabricated neural probes. PLoS One 6(10):1-11.
- [67]Steyaert MSJ, Sansen WM, Zhongyuan C (1987) A micropower low-noise monolithic instrumentation amplifier for medical purposes. IEEE J Solid-State Circuits 22(6):1163-8.
- [68]Weinstein R (2005) RFID: a technical overview and its application to the enterprise. IEEE IT Pro 27:33.
- [69]Finkenzeller K (2003) RFID Handbook: Fundamentals and Applications in Contactless Smart Cards and Identification. Wiley, New York .
- [70]Yazicioglu RF, Kim S, Torfs T, Kim H, Van Hoof C (2011) A 30 µ WAnalog Signal Processor ASIC for Portable Biopotential Signal Monitoring. IEEE J Solid-State Circuits 46(1):209-23.
- [71]Fan Q, Huijsing J, Makinwa K (2012) A capacitively coupled chopper instrumentation amplifier with a ± 30V common-mode range, 160dB CMRR and 5 µ V offset. IEEE ISSCC 374-6.
- [72]Sanni A, Vilches A, Toumazou C (2012) Inductive and Ultrasonic Multi-Tier Interface for Low-Power, Deeply Implantable Medical Devices. IEEE Trans BioCAS 6(4):297308.
- [73]Otis B, Chee YH, Rabaey JM (2005) A 400 µ W-RX, 1.6 mW-TX super-regenerative transceiver for wireless sensor networks. IEEE ISSCC 396-7.
- [74]Proakis JG (2000) Digital Communication. McGraw-Hill .
- [75]Sillon N, Astier A, Boutry H, Di Cioccio L, Henry D, Leduc P (2008) Enabling technologies for 3D integration: From packaging miniaturization to advanced stacked ICs. IEEE Elect Dev Meeting 1-4.
- [76]Smith B, Kwok P, Thompson J, Mueller A, Racz L (2010) Demonstration of a Novel Hybrid Silicon-Resin High Density Interconnect (HDI) Substrate. IEEE Proc Elect Comp Tech Conf 816-21.
- [79]Lin Y, Li S, Ren Z, Nguyen CTC (2005) Low phase noise array-composite micromechanical wine-glass disk oscillator. IEEE Elec Dev Meeting 1-4.
Cited by
Sorted by citations
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557 · see citing works
Self-citationNext-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514 · see citing works
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293 · see citing works
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158 · see citing works
Self-citationNason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113 · see citing works
Recent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99 · see citing works
Martins, N. R. B., Angelica, A., Chakravarthy, K., Svidinenko, Y., Boehm, F. J., Opris, I., Lebedev, M. A., Swan, M., Garan, S. A., Rosenfeld, J. V., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00112 · Cited by 91 · see citing works
Lee, S., & Lee, C. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.05.004 · Cited by 48 · see citing works
Comparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21 · see citing works
- Authors
- Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M.
- Affiliations
- University of California, Berkeley (US)
- Venue
- arXiv
- Publisher
- arXiv
- Published
- 2013
- ISSN
- 2331-8422 (ISSN-L)
- arXiv
- 1307.2196
- OpenAlex
- W2100602452
- Cited by
- 172
- References
- 5
- Citations by year
- 2025: 3 · 2024: 4 · 2023: 7 · 2022: 9 · 2021: 19 · 2020: 15 · 2019: 16 · 2018: 19 · 2017: 21 · 2016: 19 · 2015: 20 · 2014: 13 · 2013: 7
- Type
- posted content
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- brain-computer interface, chronic neural recording, backscatter communication, implantable neural interfaces, low-power CMOS, extracellular electrophysiology, wireless power transfer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review