PDMS-Based Low Cost Flexible Dry Electrode for Long-Term EEG Measurement
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, a novel flexible dry electrode for long-term electroencephalogram (EEG) measurement is presented. Though the standard wet electrodes (Ag/AgCl) were used widely, they have their own drawbacks, such as the need for conductive gel and skin preparation, which causes the user discomfort and is unsafe, and cannot fit the long-term EEG measurement. To overcome these drawbacks of the wet electrodes, a novel flexible dry electrode made of Polydimethysiloxane is proposed; it works without conductive gel and skin preparation. More importantly, this flexible dry electrode with pins structure can directly measure the EEG of hairy sites through hair. The impedances in frequency and time domains are tested to characterize the performance of the proposed dry electrode. In addition, to estimate signal quality, the average correlation and the power spectrum are presented between different electrodes. This flexible dry electrode can meet the requirement of high quality EEG measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Novel dry electrodes for ECG monitoring
Gruetzmann, A., Hansen, S., & Müller, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/005 · Cited by 248 · cited 1×
“The characterization of the PDMS-based dry electrode is demonstrated by impedance measurement method which proposed by other researchers [7], [22].”
Method
Cited by
Zheng, W.-L., & Lu, B.-L. (2015) · IEEE Transactions on Autonomous Mental Development · doi:10.1109/tamd.2015.2431497 · Cited by 2,595
Choi, S., Han, S. I., Jung, D., Hwang, H. J., Lim, C., Bae, S., Park, O. K., Tschabrunn, C. M., Lee, M., Bae, S. Y., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0226-8 · Cited by 984
Materials and Optimized Designs for Human‐Machine Interfaces Via Epidermal Electronics
Jeong, J., Yeo, W., Akhtar, A., Norton, J. J. S., Kwack, Y., Li, S., Jung, S., Su, Y., Lee, W., Xia, J., et al. (2013) · Advanced Materials · doi:10.1002/adma.201301921 · Cited by 827
Norton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387
Xu, B., Akhtar, A., Liu, Y., Chen, H., Yeo, W., Park, S. I., Boyce, B., Kim, H., Yu, J., Lai, H., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504155 · Cited by 304
Metadata
- Authors
- Wang, L.-F., Liu, J.-Q., Yang, B., & Yang, C.-S.
- Venue
- IEEE Sensors Journal
- Published
- 2012-09
- Volume
- 12
- Issue
- 9
- Pages
- 2898-2904
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2053212969
- Cited by
- 119
- References
- 1
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.