The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
HMM-Based Human Fall Detection and Prediction Method Using Tri-Axial Accelerometer
Abstract
Falls in the elderly have always been a serious medical and social problem. To detect and predict falls, a hidden Markov model (HMM)-based method using tri-axial accelerations of human body is proposed. A wearable motion detection device using tri-axial accelerometer is designed and realized, which can detect and predict falls based on tri-axial acceleration of human upper trunk. The acceleration time series (ATS) extracted from human motion processes are used to describe human motion features, and the ATS extracted from human fall courses but before the collision are used to train HMM so as to build a random process mathematical model. Thus, the outputs of HMM, which express the marching degrees of input ATS and HMM, can be used to evaluate the risks to fall. The experiment results show that fall events can be predicted 200–400 ms ahead the occurrence of collisions, and distinguished from other daily life activities with an accuracy of 100%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743 · cited 1×
“To train λ and calculate P(O |λ), standard Baum-Welch algorithm [18], [19] is utilized in this paper, which is a particular case of a generalized expectation maximization (GEM) algorithm.”
MethodA wearable system for pre-impact fall detection
Nyan, M. N., Tay, F. E. H., & Murugasu, E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.009 · Cited by 241
Mobile Human Airbag System for Fall Protection Using MEMS Sensors and Embedded SVM Classifier
Shi, G., Chan, C. S., Li, W. J., Leung, K.-S., Zou, Y., & Jin, Y. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2008.2012212 · Cited by 162
Cited by
A High Reliability Wearable Device for Elderly Fall Detection
Pierleoni, P., Belli, A., Palma, L., Pellegrini, M., Pernini, L., & Valenti, S. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2423562 · Cited by 276
Wearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263
IoT-based Technologies for Addressing the Unique Healthcare Needs of the Elderly Population
Ali, S. A., & Khan, R. (2023) · doi:10.20944/preprints202303.0088.v1 · Cited by 7
Metadata
- Authors
- Tong, L., Song, Q., Ge, Y., & Liu, M.
- Venue
- IEEE Sensors Journal
- Published
- 2013-05
- Volume
- 13
- Issue
- 5
- Pages
- 1849-1856
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2088371259
- Cited by
- 238
- References
- 3
- FWCI
- 25.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.