The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Empirical Mode Decomposition vs. Wavelet Decomposition for the Extraction of Respiratory Signal From Single-Channel ECG: A Comparison
Abstract
The respiratory signal can be accurately evaluated by single-channel electrocardiogram (ECG) processing, as shown in recent literature. Indirect methods to derive the respiratory signal from ECG can benefit from a simultaneous study of both respiratory and cardiac activities. These methods lead to major advantages such as low cost, high efficiency, and continuous noninvasive respiratory monitoring. The aim of this paper is to reconstruct the waveform of the respiratory signal by processing single-channel ECG. To achieve these goals, two techniques of decomposition of the ECG signal into suitable bases of functions are proposed, such as the empirical mode decomposition (EMD) and the wavelet analysis. The results highlight the main differences between them in terms of both theoretical foundations, and performance achieved by applying these algorithms to extract the respiratory waveform shape from single-channel ECG are presented. The results also show that both algorithms are able to reconstruct the respiratory waveform, although the EMD is able to break down the original signal without a preselected basis function, as it is necessary for wavelet decomposition. The EMD outperforms the wavelet approach. Some results on experimental data are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
Cited by
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Successive variational mode decomposition
Nazari, M., & Sakhaei, S. M. (2020) · Signal Processing · doi:10.1016/j.sigpro.2020.107610 · Cited by 500
A wavelet-based technique to predict treatment outcome for Major Depressive Disorder
Mumtaz, W., Xia, L., Mohd Yasin, M. A., Azhar Ali, S. S., & Malik, A. S. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171409 · Cited by 268
Taran, S., & Bajaj, V. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.03.015 · Cited by 110
Satija, U., Ramkumar, B., & Manikandan, M. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877055 · Cited by 102
Metadata
- Authors
- Labate, D., Foresta, F. L., Occhiuto, G., Morabito, F. C., Lay-Ekuakille, A., & Vergallo, P.
- Venue
- IEEE Sensors Journal
- Published
- 2013-07
- Volume
- 13
- Issue
- 7
- Pages
- 2666-2674
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2115431794
- Cited by
- 201
- References
- 1
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Empirical Mode Decomposition vs. Wavelet Decomposition for the Extraction of Respiratory Signal From Single-Channel ECG: A Comparison. https://app.cochat.ai/papers/10.1109/jsen.2013.2257742
- The paper
- Labate, D., Foresta, F. L., Occhiuto, G., Morabito, F. C., Lay-Ekuakille, A., & Vergallo, P. (2013). Empirical Mode Decomposition vs. Wavelet Decomposition for the Extraction of Respiratory Signal From Single-Channel ECG: A Comparison. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2013.2257742
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.