Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Weft-Knitted Strain Sensor for Monitoring Respiratory Rate and Its Electro-Mechanical Modeling

Atalay, Ozgur, Kennon, William Richard, Demirok, Erhan·2015·IEEE Sensors Journal

Abstract

In this paper, a textile-based strain sensor has been developed to create a respiration belt. The constituent materials and the knitted structure of the textile sensor have been specifically selected and tailored for this application. Electromechanical modeling has been developed by exploiting Peirce's loop model in order to describe the fabric geometry under static and dynamic conditions. Kirchhoff's node and loop equations have been employed to create a generalized solution for the equivalent electrical resistance of the textile sensor for a given knitted loop geometry and for a specified number of loops. A laboratory test setup was built to characterize the prototype sensor and the resulting equivalent resistance under strain levels up to 40%, and consistent resistance response levels have been obtained from the sensor which correlate well with the modelled data. Production of the respiration belt was realized by bringing together knitted sensor and a relatively inelastic textile strap. Both machine simulations and real-time measurements on a human subject have been performed in order to calculate average breathing frequencies under different static and dynamic conditions. Also, different scenarios have been performed, such as slow breathing and rapid breathing. The sensory belt was located in either the chest area or in the abdominal area during the experimental measurements and the sensor yielded a good response under both static and dynamic conditions. However, body motion artefacts affected the signal quality under dynamic conditions and an additional signal-processing step was added to eliminate unwanted interference from the breathing signal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jsen.2014.2339739

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 198

Metadata

Authors
Atalay, O., Kennon, W. R., & Demirok, E.
Venue
IEEE Sensors Journal
Published
2015-01
Volume
15
Issue
1
Pages
110-122
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W2321344490
Cited by
198
References
2
FWCI
4.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Weft-Knitted Strain Sensor for Monitoring Respiratory Rate and Its Electro-Mechanical Modeling. https://app.cochat.ai/papers/10.1109/jsen.2014.2339739
The paper
Atalay, O., Kennon, W. R., & Demirok, E. (2015). Weft-Knitted Strain Sensor for Monitoring Respiratory Rate and Its Electro-Mechanical Modeling. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2014.2339739

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.