The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Weft-Knitted Strain Sensor for Monitoring Respiratory Rate and Its Electro-Mechanical Modeling
Abstract
In this paper, a textile-based strain sensor has been developed to create a respiration belt. The constituent materials and the knitted structure of the textile sensor have been specifically selected and tailored for this application. Electromechanical modeling has been developed by exploiting Peirce's loop model in order to describe the fabric geometry under static and dynamic conditions. Kirchhoff's node and loop equations have been employed to create a generalized solution for the equivalent electrical resistance of the textile sensor for a given knitted loop geometry and for a specified number of loops. A laboratory test setup was built to characterize the prototype sensor and the resulting equivalent resistance under strain levels up to 40%, and consistent resistance response levels have been obtained from the sensor which correlate well with the modelled data. Production of the respiration belt was realized by bringing together knitted sensor and a relatively inelastic textile strap. Both machine simulations and real-time measurements on a human subject have been performed in order to calculate average breathing frequencies under different static and dynamic conditions. Also, different scenarios have been performed, such as slow breathing and rapid breathing. The sensory belt was located in either the chest area or in the abdominal area during the experimental measurements and the sensor yielded a good response under both static and dynamic conditions. However, body motion artefacts affected the signal quality under dynamic conditions and an additional signal-processing step was added to eliminate unwanted interference from the breathing signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
Lanatà, A., Scilingo, E. P., Nardini, E., Loriga, G., Paradiso, R., & De-Rossi, D. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2037614 · Cited by 111
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Machine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring
Hatamie, A., Angizi, S., Kumar, S., Pandey, C. M., Simchi, A., Willander, M., & Malhotra, B. D. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab6827 · Cited by 184
Metadata
- Authors
- Atalay, O., Kennon, W. R., & Demirok, E.
- Venue
- IEEE Sensors Journal
- Published
- 2015-01
- Volume
- 15
- Issue
- 1
- Pages
- 110-122
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2321344490
- Cited by
- 198
- References
- 2
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Weft-Knitted Strain Sensor for Monitoring Respiratory Rate and Its Electro-Mechanical Modeling. https://app.cochat.ai/papers/10.1109/jsen.2014.2339739
- The paper
- Atalay, O., Kennon, W. R., & Demirok, E. (2015). Weft-Knitted Strain Sensor for Monitoring Respiratory Rate and Its Electro-Mechanical Modeling. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2014.2339739
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.