Cited by 184Advanced Sensor and Energy Harvesting MaterialsElectrochemical sensors and biosensorsNon-Invasive Vital Sign Monitoring

Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring

Open access
Hatamie, Amir, Angizi, Shayan, Kumar, Saurabh, Pandey, Chandra Mouli, Simchi, Abdolreza, Willander, Magnus, Malhotra, Bansi D.·2020·Journal of The Electrochemical Society

Abstract

The emergence of textile-based wearable sensors as light-weight portable devices to monitor desired parameters, has recently gained much interest and has led to the development of flexible electronics on non-rigid substrates. The flexible biosensors may result in improved sports performance, to monitor the desired bodies for injuries, improved clinical diagnostics and monitor biological molecules and ions in biological fluids such as saliva, sweat. In addition, they could help users with different types of disorders such as blindness. In this context, new composite and nanomaterials have been found to be promising candidates to obtain improved performance of the textile based wearable devices and to optimize the structures for intimate contact with the skin for better functionality. This review aims to provide the most recent cutting-edge information on emergence, fabrication, materials, and applications of chemical and physical flexible and stretchable textile-based (bio)sensors. Besides this, we discusss the recent key innovations and applications of textile-based sensors in healthcare.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1149/1945-7111/ab6827

Cites

118 of 118 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The stability of sensors, especially electrochemical ones, can be a problem, where passivation and biological contamination of the electrode can lead to an incorrect response.

    “The stability of sensors, especially electrochemical ones, can be a problem, where passivation and biological contamination of the electrode can lead to an incorrect response [203].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [203]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

2 of the 120 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Hatamie, A., Angizi, S., Kumar, S., Pandey, C. M., Simchi, A., Willander, M., & Malhotra, B. D.
Affiliations
  • Linköping University (SE)
  • Sharif University of Technology (IR)
  • Indian Institute of Science Bangalore (IN)
  • Delhi Technological University (IN)
Corresponding author
  • Hatamie, Amir
  • Malhotra, Bansi D.
Venue
Journal of The Electrochemical Society
Published
2020-01-02
Volume
167
Issue
3
Pages
037546
ISSN
  • 0013-4651 (ISSN-L)
  • 1945-7111
OpenAlex
W3001838948
Cited by
184
References
120
Citations by year
2026: 8 · 2025: 30 · 2024: 32 · 2023: 30 · 2022: 38 · 2021: 31 · 2020: 14 · 2019: 1
FWCI
8.89
Type
journal article
Language
en
Open access
Locations
  • Journal of The Electrochemical Society (publishedVersion, cc-by)
  • NOT FOUND REPOSITORY (Indian Institute of Science Bangalore) (acceptedVersion)
  • KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
Funders
  • Sharif University of Technology (95-S-48740)
  • Delhi Technological University (DST/INSPIRE/04/2017/002750)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
textile sensors, wearable sensors, flexible electronics, stretchable sensors, flexible biosensors, chemical sensors, physical sensors, healthcare monitoring, nanomaterials, composite materials, skin contact, sweat monitoring, clinical diagnostics, sports performance monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review