The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Spiral Photonic Crystal Fiber-Based Dual-Polarized Surface Plasmon Resonance Biosensor
Abstract
We numerically demonstrate a surface plasmon resonance biosensor-based on dual-polarized spiral photonic crystal fiber (PCF). Chemically stable gold material is used as the active plasmonic material, which is placed on the outer layer of the PCF to facilitate practical fabrication. Finite-element method-based numerical investigations show that the proposed biosensor shows maximum wavelength sensitivity of 4600 and 4300 nm/RIU in x-and y-polarized modes at an analyte refractive index of 1.37. Moreover, for analyte refractive index ranging from 1.33 to 1.38, maximum amplitude sensitivities of 371.5 RIU-1and 420.4 RIU-1are obtained in xand y-polarized modes, respectively. In addition, the effects of changing pitch, different air hole diameter of the PCF and thickness of the gold layer on the sensing performance are also investigated. Owing to high sensitivity, improved sensing resolution and appropriate linearity characteristics, the proposed dual-polarized spiral PCF can be implemented for the detection of biological analytes, organic chemicals, biomolecules, and other unknown analytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Notizen: Radiative Decay of Non Radiative Surface Plasmons Excited by Light
Kretschmann, E., & Raether, H. (1968) · Zeitschrift für Naturforschung A · doi:10.1515/zna-1968-1247 · Cited by 3,377
Plasma Losses by Fast Electrons in Thin Films
Ritchie, R. H. (1957) · Physical Review · doi:10.1103/physrev.106.874 · Cited by 3,132
Otto, A. (1968) · Zeitschrift für Physik A Hadrons and nuclei · doi:10.1007/bf01391532 · Cited by 3,065
Vial, A., Grimault, A.-S., Macías, D., Barchiesi, D., & de la Chapelle, M. L. (2005) · Physical Review B · doi:10.1103/physrevb.71.085416 · Cited by 853
Microstructured Optical Fibers as High-Pressure Microfluidic Reactors
Sazio, P. J. A., Amezcua-Correa, A., Finlayson, C. E., Hayes, J. R., Scheidemantel, T. J., Baril, N. F., Jackson, B. R., Won, D.-J., Zhang, F., Margine, E. R., et al. (2006) · Science · doi:10.1126/science.1124281 · Cited by 528
Fang, S., Lee, H. J., Wark, A. W., & Corn, R. M. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065223p · Cited by 450
Graphene-Based Birefringent Photonic Crystal Fiber Sensor Using Surface Plasmon Resonance
Dash, J. N., & Jha, R. (2014) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2014.2315233 · Cited by 298
Yang, X., Lu, Y., Liu, B., & Yao, J. (2017) · Plasmonics · doi:10.1007/s11468-016-0289-z · Cited by 200
A Highly Sensitive Gold-Coated Photonic Crystal Fiber Biosensor Based on Surface Plasmon Resonance
Hasan, M., Akter, S., Rifat, A., Rana, S., & Ali, S. (2017) · Photonics · doi:10.3390/photonics4010018 · Cited by 195
Self-citation
Cited by
Optical biosensors: A decade in review
Singh, A. K., Mittal, S., Das, M., Saharia, A., & Tiwari, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.12.040 · Cited by 292
Metadata
- Authors
- Hasan, M. R., Akter, S., Rifat, A. A., Rana, S., Ahmed, K., Ahmed, R., Subbaraman, H., & Abbott, D.
- Venue
- IEEE Sensors Journal
- Published
- 2018-01-01
- Volume
- 18
- Issue
- 1
- Pages
- 133-140
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2765517572
- Cited by
- 298
- References
- 14
- FWCI
- 10.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spiral Photonic Crystal Fiber-Based Dual-Polarized Surface Plasmon Resonance Biosensor. https://app.cochat.ai/papers/10.1109/jsen.2017.2769720
- The paper
- Hasan, M. R., Akter, S., Rifat, A. A., Rana, S., Ahmed, K., Ahmed, R., Subbaraman, H., & Abbott, D. (2018). Spiral Photonic Crystal Fiber-Based Dual-Polarized Surface Plasmon Resonance Biosensor. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2017.2769720
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.