The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Smart Textile Using Hetero-Core Optical Fiber for Heartbeat and Respiration Monitoring
Open accessAbstract
This paper aims to describe a novel smart textile that uses a single-mode hetero-core optical fiber sensor for monitoring heartbeat and respiration. The smart textile was designed by weaving hetero-core optical fibers together with the wool fabric. This novel textile that can detect variations in shapes can be incorporated into clothes. Such clothes can offer comfort to the wearer. To simultaneously monitor heartbeat and respiration, the proposed textile is sewn on to the clothes to be able to sense minute load changes produced by chest movements. The vital signs, which were calculated from the heartbeat and respiration frequency of a healthy adult, while sitting, were in agreement with those verified using commercial monitoring devices. In addition, to confirm the capability of monitoring vital signs, seven monitoring trials were performed in which the subjects were asked to wear and take off the smart cloth. The vital signs rates were successfully extracted within the four beats per minute error by the fiber optic sensor system. The proposed smart textile in clothes can monitor vital signs in daily life activities, such as sitting and standing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Hetero-core optical fiber woven together with wool fibers [208] offers a simple and cost-effective system for monitoring HR and RR.”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [208]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Wearable Health Care System Based on Knitted Integrated Sensors
Paradiso, R., Loriga, G., & Taccini, N. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854512 · Cited by 729
Optical Fiber Sensors Embedded Into Medical Textiles for Healthcare Monitoring
Grillet, A., Kinet, D., Witt, J., Schukar, M., Krebber, K., Pirotte, F., & Depré, A. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.926518 · Cited by 234
Textile Pressure Sensor Made of Flexible Plastic Optical Fibers
Rothmaier, M., Luong, M. P., & Clemens, F. J. (2008) · Sensors · doi:10.3390/s8074318 · Cited by 203
A Non-Invasive Multichannel Hybrid Fiber-Optic Sensor System for Vital Sign Monitoring
Fajkus, M., Nedoma, J., Martínek, R., Vašinek, V., Nazeran, H., & Šiška, P. (2017) · Sensors · doi:10.3390/s17010111 · Cited by 177
Medical Textiles With Embedded Fiber Optic Sensors for Monitoring of Respiratory Movement
Witt, J., Narbonneau, F., Schukar, M., Krebber, K., Jonckheere, J. D., Jeanne, M., Kinet, D., Paquet, B., Depré, A., D’Angelo, L., et al. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2158416 · Cited by 167
Performance Evaluation of Textile-Based Electrodes and Motion Sensors for Smart Clothing
Cho, G., Jeong, K., Paik, M., Kwun, Y., & Sung, M. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2167508 · Cited by 158
Ciocchetti, M., Massaroni, C., Saccomandi, P., Caponero, M., Polimadei, A., Formica, D., & Schena, E. (2015) · Biosensors · doi:10.3390/bios5030602 · Cited by 142
Textile Fiber Optic Microbend Sensor Used for Heartbeat and Respiration Monitoring
Yang, X., Chen, Z., Elvin, C. S. M., Janice, L. H. Y., Ng, S. H., Teo, J. T., & Wu, R. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2353640 · Cited by 142
Photonic textiles for pulse oximetry
Rothmaier, M., Selm, B., Spichtig, S., Haensse, D., & Wolf, M. (2008) · Optics Express · doi:10.1364/oe.16.012973 · Cited by 112
Printed Stretchable Interconnects for Smart Garments: Design, Fabrication, and Characterization
Yokus, M. A., Foote, R., & Jur, J. S. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2605071 · Cited by 94
Massaroni, C., Saccomandi, P., Formica, D., Presti, D. L., Caponero, M., Tomaso, G. D., Giurazza, F., Muto, M., & Schena, E. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2606487 · Cited by 87
Watanabe, K., Tajima, K., & Kubota, Y. (2000) · IEICE Transactions on Electronics · Cited by 84
Self-citationNishyama, M., Miyamoto, M., & Watanabe, K. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3528008 · Cited by 80
Self-citationApplication of Fiber Bragg Gratings to Wearable Garments
Carmo, J. P., da Silva, A. F., Rocha, R. P., & Correia, J. H. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2161281 · Cited by 51
A Motion Monitor Using Hetero-Core Optical Fiber Sensors Sewed in Sportswear to Trace Trunk Motion
Koyama, Y., Nishiyama, M., & Watanabe, K. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2241534 · Cited by 40
Self-citationUnconstrained pulse pressure monitoring for health management using hetero-core fiber optic sensor
Nishiyama, M., Sonobe, M., & Watanabe, K. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003675 · Cited by 31
Self-citationOptical Properties of Woven Fabrics by Plastic Optical Fiber
Masuda, A., Murakami, T., HONDA, K., & Yamaguchi, S. (2006) · Journal of Textile Engineering · doi:10.4188/jte.52.93 · Cited by 27
A Hetero-Core Splice Fiber Optic Displacement Sensor and the Accuracy Evaluation
Sasaki, H., Kubota, Y., & Watanabe, K. (2004) · Transactions of the Society of Instrument and Control Engineers · doi:10.9746/sicetr1965.40.981 · Cited by 18
Self-citationA novel periodic macrobending hetero-core fiber optic sensor embedded in textiles
Alemdar, K., Likoglu, S., Fidanboylu, K., & Toker, O. (2013) · National Conference on Electrical and Electronics Engineering (ELECO) · doi:10.1109/eleco.2013.6713886 · Cited by 11
da Silva, A. F., Goncalves, F., Mendes, P. M., & Correia, J. H. (2010) · Polymers for Advanced Technologies · doi:10.1002/pat.1855 · Cited by 8
Smart Textile with Plain Weave Structure Using Hetero-Core Optical Fiber Sensor and Wool Threads
Koyama, Y., Nishiyama, M., & Watanabe, K. (2018) · doi:10.1109/icoias.2018.8493642 · Cited by 5
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- 2018, Fiber Optics Sensing i-Line Series Controller(i-Line BOX8B)
Cited by
Sorted by citations
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Presti, D. L., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 465
Zhou, Z., Padgett, S., Cai, Z., Conta, G., Wu, Y., He, Q., Zhang, S., Sun, C., Liu, J., Fan, E., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112064 · Cited by 318
Textile Technology for Soft Robotic and Autonomous Garments
Sanchez, V., Walsh, C. J., & Wood, R. J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202008278 · Cited by 306
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 276
Khan, S., Ali, S., & Bermak, A. (2019) · Sensors · doi:10.3390/s19051230 · Cited by 259
Metadata
- Authors
- Koyama, Y., Nishiyama, M., & Watanabe, K.
- Affiliations
- Soka University (JP)
- Venue
- IEEE Sensors Journal
- Published
- 2018-08-01
- Volume
- 18
- Issue
- 15
- Pages
- 6175-6180
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2808223900
- Cited by
- 126
- References
- 21
- Citations by year
- 2026: 9 · 2025: 14 · 2024: 20 · 2023: 19 · 2022: 29 · 2021: 12 · 2020: 12 · 2019: 8 · 2018: 3
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- IEEE Sensors Journal (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (JP 17K18185)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
- Keywords
- hetero-core optical fiber, fiber optic sensors, heart rate monitoring, respiratory monitoring, vital signs monitoring, wearable sensing, wool fabrics, single-mode fiber
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review