Noninvasive Monitoring of Vital Signs Based on Highly Sensitive Fiber Optic Mattress
Open accessAbstract
A smart mattress based on optical fiber Mach-Zender interferometer (OF-MZI) is designed for noninvasive and continuous monitoring of human vital signs. Through arranging the sensing fiber between two elastic covering layers with sandwich structure, the mattress was sensitive to the respiration and heartbeat induced micro-pressure. In the processing terminal, the waveforms of vital signs were demodulated by 3*3 coupler based differentiate and cross-multiplying method, and then four characteristic indicators including the heart rate, heartbeat amplitude, respiration rate, and respiration amplitude were respectively extracted through feature extraction algorithm, for evaluating the human health condition. Clinical experimental results of eighteen subjects indicate that the mattress system could not only distinguish the activity states of no body, on bed, body movement and off bed, but also contribute to clinical diagnosis of bradycardia, tachycardia, polypnea and apnoea. By adopting Bland-Altman analysis method, good reproducibility and accuracy were confirmed, where the max errors of heart rate and respiration rate are respectively 2 bpm and 1 bpm. Moreover, the responses at different positions of the mattress are identical and the continuous monitoring results in one day are consistent with daily change of vital signs, which proves that the fiber optic mattress has good reliability and stability. Beneficial from high-sensitivity, multiple parameters, long-term continuous monitoring, high comfortability and low cost, the mattress is promising in the early detection and prevention of cardiac and respiratory diseases as a household medical device.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A fiber sandwich structure with a three × three coupler-based differentiate and cross-multiplying method achieves good reproducibility and accuracy with maximum errors of 2 bpm and 1 rpm in monitoring HR, HR amplitude, RR, and respiration amplitude.
“They applied a three × three coupler-based differentiate and cross-multiplying method [237] to achieve good reproducibility and accuracy with max. errors 2 bpm and 1 rpm in monitoring HR, HR amplitude, RR, and respiration amplitude.”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [237]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Mechanics of composite materials
(1999) · Choice Reviews Online · doi:10.5860/choice.36-5715 · Cited by 2,345 · see citing works
hERG potassium channels and cardiac arrhythmia
Sanguinetti, M. C., & Tristani‐Firouzi, M. (2006) · Nature · doi:10.1038/nature04710 · Cited by 1,582 · see citing works
Ganong's Review of Medical Physiology
Barrett, K. E. (2009) · Repository of the University of Ljubljana (University of Ljubljana) · Cited by 1,100 · see citing works
A distributed optical fibre dynamic strain sensor based on phase-OTDR
Masoudi, A., Belal, M., & Newson, T. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/8/085204 · Cited by 493 · see citing works
Three-dimensional finite element analysis of the foot during standing—a material sensitivity study
Cheung, J. T., Zhang, M., Leung, K. L., et al. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.035 · Cited by 453 · see citing works
Age-Related Abnormalities in Arterial Compliance Identified by Pressure Pulse Contour Analysis
McVeigh, G. E., Bratteli, C. W., Morgan, D. J., Alinder, C. M., Glasser, S. P., Finkelstein, S. M., & Cohn, J. N. (1999) · Hypertension · doi:10.1161/01.hyp.33.6.1392 · Cited by 382 · see citing works
A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration
Alihanka, J., Vaahtoranta, K., & Saarikivi, I. (1981) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1981.240.5.r384 · Cited by 272 · see citing works
A Smart Health Monitoring Chair for Nonintrusive Measurement of Biological Signals
Baek, H. J., Chung, G. S., Kim, K. K., & Park, K. S. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2175742 · Cited by 198 · see citing works
Monitoring Respiration and Cardiac Activity Using Fiber Bragg Grating-Based Sensor
Dziuda, Ł., Skibniewski, F. W., Krej, M., & Lewandowski, J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2194145 · Cited by 186 · see citing works
Distributed OTDR-interferometric sensing network with identical ultra-weak fiber Bragg gratings
Wang, C., Shang, Y., Liu, X., et al. (2015) · Optics Express · doi:10.1364/oe.23.029038 · Cited by 174 · see citing works
Noncontact Respiration Rate Measurement System Using an Ultrasonic Proximity Sensor
Min, S. D., Kim, J. K., Shin, H., Yun, Y. H., Lee, C. K., & Lee, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2044239 · Cited by 168 · see citing works
Monitoring of respiratory and heart rates using a fibre-optic sensor
Lindberg, L., Ugnell, H., & Öberg, P. Å. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457833 · Cited by 158 · see citing works
Junior, A. G. L., Díaz, C. A. R., Leitão, C., Pontes, M. J., Marques, C., & Frizera, A. (2018) · Optics & Laser Technology · doi:10.1016/j.optlastec.2018.08.036 · Cited by 151 · see citing works
Distributed acoustic mapping based on interferometry of phase optical time-domain reflectometry
Wang, C., Wang, C., Wang, C., et al. (2015) · Optics Communications · doi:10.1016/j.optcom.2015.02.044 · Cited by 117 · see citing works
Development of a PVDF Piezopolymer Sensor for Unconstrained In-Sleep Cardiorespiratory Monitoring
Wang, F., Tanaka, M., & CHONAN, S. (2003) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x03014003006 · Cited by 114 · see citing works
Chee, Y., Han, J., Youn, J., & Park, K. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/4/007 · Cited by 111 · cited 1× · see citing works
“Furthermore, the sensors based on polyvinylidene fluoride (PVDF) piezopolymer film [5], static charge-sensitive-bed (SCSB) [6], ECG [7], Doppler radar [8], acoustic sensor [9], air mattress [10] and liquid pressure mattress [11] have been adopted to simultaneous measure respiration rate and heart rate.”
MethodFiber Bragg Grating Strain Sensor Incorporated to Monitor Patient Vital Signs During MRI
Dziuda, Ł., Krej, M., & Skibniewski, F. W. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2279160 · Cited by 107 · see citing works
Improved, operationally-passive interferometric demodulation method using 3×3 coupler
Todd, M. D., Seaver, M., & Bucholtz, F. (2002) · Electronics Letters · doi:10.1049/el:20020569 · Cited by 84 · see citing works
Noninvasive Measurement of Physiological Signals on a Modified Home Bathroom Scale
Inan, O. T., Park, D., Giovangrandi, L., & Kovacs, G. T. A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2186809 · Cited by 62 · see citing works
A Non-Contact Vital Signs Monitor
Matthews, G., Sudduth, B., & Burrow, M. (2000) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v28.i12.290 · Cited by 60 · see citing works
A miniature optical breathing sensor
Mathew, J., Semenova, Y., & Farrell, G. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.003325 · Cited by 55 · see citing works
Ziraki, S., Zebarjad, S. M., & Hadianfard, M. J. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.01.019 · Cited by 55 · see citing works
Microstructured optical fiber interferometric breathing sensor
Fávero, F., Pruneri, V., & Villatoro, J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.3.037006 · Cited by 51 · see citing works
Multiparameter Sleep Monitoring Using a Depth Camera
Yu, M.-C., Wu, H., Liou, J.-L., Lee, M., & Hung, Y. (2013) · Communications in computer and information science · doi:10.1007/978-3-642-38256-7_21 · Cited by 41 · see citing works
Noninvasive Measurement of Heart Rate and Respiratory Rate for Perioperative Infants
Zhang, Y., Chen, Z., & Hee, H. I. (2018) · Journal of Lightwave Technology · doi:10.1109/jlt.2018.2883413 · Cited by 37 · see citing works
Wo, J., Wang, H., Sun, Q., et al. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.017003 · Cited by 30 · see citing works
Self-citationMicrostructured Optical Fiber Based Distributed Sensor for In Vivo Pressure Detection
Zhang, W., Ni, X., Wang, J., et al. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2019.2894299 · Cited by 20 · see citing works
Self-citationAlmehmadi, F. S., & Chatterjee, M. R. (2015) · Applied Optics · doi:10.1364/ao.54.000195 · Cited by 15 · see citing works
A breath sensor using carbon nanotubes operated by field effects of polarization and ionization
Chen, X., Wang, Y., Wang, Y., et al. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.01.021 · Cited by 15 · see citing works
Acoustically monitor physiology during sleep and activity
Scanlon, M. V. (2003) · doi:10.1109/iembs.1999.803942 · Cited by 12 · see citing works
Vibration Sensor Based on the Resonance Power Leakage in a Tapered Capillary Fiber
Gao, R., Lu, D., Zhang, M., et al. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2765891 · Cited by 11 · see citing works
Nishiyama, M., Miyamoto, M., & Watanabe, K. (2010) · doi:10.1109/iccas.2010.5669885 · Cited by 7 · see citing works
Study on sleep monitering with micromovement sensitive mattress monitering system
Yu-bin, Z. (1999) · Chinese Journal of Aerospace Medicine · Cited by 5 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- S. C. Tjin, R. Suresh, and N. Q. Ngo, "Fiber Bragg grating based shear- force during standing-a material sensitivity study," J. Biomech., vol. 38, no. 5, pp. 1045-1054, 2005.
Cited by
Sorted by citations
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103 · see citing works
- Authors
- Wang, S., Ni, X., Li, L., Wang, J., Liu, Q., Yan, Z., Zhang, L., & Sun, Q.
- Affiliations
- Huazhong University of Science and Technology (CN)
- Huazhong University of Science and Technology Hospital (CN)
- Aston University (GB)
- Venue
- IEEE Sensors Journal
- Published
- 2020-06-01
- Volume
- 20
- Issue
- 11
- Pages
- 6182-6190
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W3007661370
- Cited by
- 71
- References
- 34
- Citations by year
- 2026: 8 · 2025: 9 · 2024: 13 · 2023: 18 · 2022: 12 · 2021: 11
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Aston Publications Explorer (Aston University) (submittedVersion)
- Funders
- Wuhan Morning Light Plan of Youth Science and Technology (2017050304010280)
- National Natural Science Foundation of China (61922033, 61775072)
- Science Fund for Creative Research Groups of the Natural Science Foundation of Hubei (2018CFA004)
- Fundamental Research Funds for the Central Universities (2019kfyRCPY095)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- non-invasive vital sign monitoring, heart rate monitoring, respiration rate monitoring, smart mattress, pressure sensing, bradycardia detection, tachycardia detection, apnea detection, polypnea, home medical devices, continuous physiological monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review