CoChat

Determining Physical Activity Characteristics From Wristband Data for Use in Automated Insulin Delivery Systems

Open access
Sevil, Mert, Rashid, Mudassir, Maloney, Zacharie, Hajizadeh, Iman, Samadi, Sediqeh, Askari, Mohammad Reza, Hobbs, Nicole, Brandt, Rachel, Park, Minsun, Quinn, Laurie, Cinar, Ali · 2020 · IEEE Sensors Journal
Cited by 60

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Algorithms that can determine the type of physical activity (PA) and quantify the intensity can allow precision medicine approaches, such as automated insulin delivery systems that modulate insulin administration in response to PA. In this work, data from a multi-sensor wristband is used to design classifiers to distinguish among five different physical states (PS) (resting, activities of daily living, running, biking, and resistance training), and to develop models to estimate the energy expenditure (EE) of the PA for diabetes therapy. The data collected are filtered, features are extracted from the reconciled signals, and the extracted features are used by machine learning algorithms, including deep-learning techniques, to obtain accurate PS classification and EE estimation. The various machine learning techniques have different success rates ranging from 75.7% to 94.8% in classifying the five different PS. The deep neural network model with long short-term memory has 94.8% classification accuracy. We achieved 0.5 MET (Metabolic Equivalent of Task) root-mean-square error for EE estimation accuracy, relative to indirect calorimetry with randomly selected testing data (10% of collected data). We also demonstrate a 5% improvement in PS classification accuracy and a 0.34 MET decrease in the mean absolute error when using multi-sensor approach relative to using only accelerometer data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jsen.2020.3000772

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 60

Metadata

Authors
Sevil, M., Rashid, M., Maloney, Z., Hajizadeh, I., Samadi, S., Askari, M. R., Hobbs, N., Brandt, R., Park, M., Quinn, L., & Cinar, A.
Venue
IEEE Sensors Journal
Published
2020-11-01
Volume
20
Issue
21
Pages
12859-12870
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W3034496655
Cited by
60
References
22
FWCI
3.31
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determining Physical Activity Characteristics From Wristband Data for Use in Automated Insulin Delivery Systems. https://app.cochat.ai/papers/10.1109/jsen.2020.3000772
The paper
Sevil, M., Rashid, M., Maloney, Z., Hajizadeh, I., Samadi, S., Askari, M. R., Hobbs, N., Brandt, R., Park, M., Quinn, L., & Cinar, A. (2020). Determining Physical Activity Characteristics From Wristband Data for Use in Automated Insulin Delivery Systems. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2020.3000772

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.