CoChat

Layer-Wise Training Convolutional Neural Networks With Smaller Filters for Human Activity Recognition Using Wearable Sensors

Open access
Tang, Yin, Teng, Qi, Zhang, Lei, Min, Fuhong, He, Jun · 2021 · IEEE Sensors Journal
Cited by 143

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Recently, convolutional neural networks (CNNs) have set latest state-of-the-art on various human activity recognition (HAR) datasets. However, deep CNNs often require more computing resources, which limits their applications in embedded HAR. Although many successful methods have been proposed to reduce memory and FLOPs of CNNs, they often involve special network architectures designed for visual tasks, which are not suitable for deep HAR tasks with time series sensor signals, due to remarkable discrepancy. Therefore, it is necessary to develop lightweight deep models to perform HAR. As filter is the basic unit in constructing CNNs, it deserves further research whether re-designing smaller filters is applicable for deep HAR. In the article, inspired by the idea, we proposed a lightweight CNN using Lego filters for HAR. A set of lower-dimensional filters is used as Lego bricks to be stacked for conventional filters, which does not rely on any special network structure. The local loss function is used to train model. To our knowledge, this is the first paper that proposes lightweight CNN for HAR in ubiquitous and wearable computing arena. The experiment results on five public HAR datasets, UCI-HAR dataset, OPPORTUNITY dataset, UNIMIB-SHAR dataset, PAMAP2 dataset, and WISDM dataset collected from either smartphones or multiple sensor nodes, indicate that our novel Lego CNN with local loss can greatly reduce memory and computation cost over CNN, while achieving higher accuracy. That is to say, the proposed model is smaller, faster and more accurate. Finally, we evaluate the actual performance on an Android smartphone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jsen.2020.3015521

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 143

Metadata

Authors
Tang, Y., Teng, Q., Zhang, L., Min, F., & He, J.
Venue
IEEE Sensors Journal
Published
2021-01-01
Volume
21
Issue
1
Pages
581-592
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W3048952742
Cited by
143
References
23
FWCI
9.15
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Layer-Wise Training Convolutional Neural Networks With Smaller Filters for Human Activity Recognition Using Wearable Sensors. https://app.cochat.ai/papers/10.1109/jsen.2020.3015521
The paper
Tang, Y., Teng, Q., Zhang, L., Min, F., & He, J. (2021). Layer-Wise Training Convolutional Neural Networks With Smaller Filters for Human Activity Recognition Using Wearable Sensors. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2020.3015521

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.