The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Stability of Metal Oxide Semiconductor Gas Sensors: A Review
Open accessAbstract
Sensor stability is defined as the ability to maintain a relatively stable and repeatable signal over a sufficient period. Long-term stability for gas sensors is an essential capability for carrying out long-term data collection of human exhaled breath, environmental monitoring and other gas detection in the modern electronic information age. This article reviews the research advances on the stability of metal oxide semiconductor gas sensors in the past five years. The impact of structure, environment, toxicity and sensor array on the sensor stability are discussed. Then, the improvement schemes of existing materials and structure design are summarized. The achievements of structure doping, humidity, anti-poisoning and photoactivation are overviewed. Finally, the great significance of elucidating the sensing mechanism and carrying out the life acceleration test for future research and development is pointed out.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanisms of catalyst deactivation
Bartholomew, C. H. (2001) · Applied Catalysis A: General · doi:10.1016/s0926-860x(00)00843-7 · Cited by 3,083
Room-temperature gas sensing of ZnO-based gas sensor: A review
Zhu, L., & Zeng, W. (2017) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2017.10.021 · Cited by 1,105
Zinc Oxide Nanostructures for NO2 Gas–Sensor Applications: A Review
Kumar, R., Al-Dossary, O., Kumar, G., & Umar, A. (2015) · Nano-Micro Letters · doi:10.1007/s40820-014-0023-3 · Cited by 900
Flexible Graphene-Based Wearable Gas and Chemical Sensors
Singh, E., Meyyappan, M., & Nalwa, H. S. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07063 · Cited by 776
First Fifty Years of Chemoresistive Gas Sensors
Neri, G. (2015) · Chemosensors · doi:10.3390/chemosensors3010001 · Cited by 530
Degler, D., Weimar, U., & Barsan, N. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00975 · Cited by 519
Stability and Reactivity: Positive and Negative Aspects for Nanoparticle Processing
Xu, L., Liang, H.-W., Yang, Y., & Yu, S.-H. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00208 · Cited by 472
Jeong, S., Kim, J., & Lee, J. (2020) · Advanced Materials · doi:10.1002/adma.202002075 · Cited by 415
Romain, A. C., & Nicolas, J. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.12.027 · Cited by 334
Li, H.-Y., Lee, C.-S., Kim, D. H., & Lee, J.-H. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b09169 · Cited by 310
Cited by
Supporting wound infection diagnosis: advancements and challenges with electronic noses
Wörner, J., Moelleken, M., Dissemond, J., & Pein-Hackelbusch, M. (2023) · Frontiers in Sensors · doi:10.3389/fsens.2023.1250756 · Cited by 8
Metadata
- Authors
- Chai, H., Zheng, Z., Liu, K., Xu, J., Wu, K., Luo, Y., Liao, H., Debliquy, M., & Zhang, C.
- Venue
- IEEE Sensors Journal
- Published
- 2022-03-15
- Volume
- 22
- Issue
- 6
- Pages
- 5470-5481
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W4212808904
- Cited by
- 277
- References
- 46
- FWCI
- 12.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stability of Metal Oxide Semiconductor Gas Sensors: A Review. https://app.cochat.ai/papers/10.1109/jsen.2022.3148264
- The paper
- Chai, H., Zheng, Z., Liu, K., Xu, J., Wu, K., Luo, Y., Liao, H., Debliquy, M., & Zhang, C. (2022). Stability of Metal Oxide Semiconductor Gas Sensors: A Review. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2022.3148264
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.