A Novel Compensatory Motion Detection Method Using Multiple Signals and Machine Learning
The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index.
Abstract
Harmful compensatory motion will seriously influence the upper limb rehabilitation effect of stroke patients. Existing compensatory motion pattern detection methods, which are mainly based on accelerometers, inertial measurement units (IMUs), and vision, have problems such as high installation requirements, calibration difficulty, object occlusion, and complex operations. To solve these problems, by analyzing the principle of compensatory motion, this paper designs a trunk restraint belt, compensation motion mode detection system that is composed of a force sensor (F-S), angular displacement sensor (AD-S), and surface electromyography (sEMG). Fifteen healthy subjects without dyskinesia completed normal motion and simulated compensatory movement modes (trunk rotation, trunk forward tilt, and scapular elevation) based on the system. Machine learning (ML) methods are used to classify three compensated motion and normal motion (NM). Among them, the support vector machine (SVM) classifier shows good classification performance for trunk forward tilt (F1-score = 0.9256), shoulder blade elevation (F1-score = 0.9190), trunk rotation (F1-score = 0.8262) and normal motion (F1-score = 0.9758). This method is a new compensation detection method with obvious advantages: it is easy to wear, and without considering the problems of calibration and target occlusion, it can not only identify the patient motion mode but also limit the large range of compensatory motion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“| IMU and sEMG | SVM | 97.6% | 1% | 273 |”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [273]
Citations
Cites
A systematic analysis of performance measures for classification tasks
Sokolova, M., & Lapalme, G. (2009) · Information Processing & Management · doi:10.1016/j.ipm.2009.03.002 · Cited by 7,515 · cited 1×
“Based on the confusion table, three accuracy metrics (precision, recall, and F1-score) can be obtained [42].”
MethodKolominsky-Rabas, P. L., Weber, M., Gefeller, O., Neundoerfer, B., & Heuschmann, P. U. (2001) · Stroke · doi:10.1161/hs1201.100209 · Cited by 1,281
Compensatory strategies for reaching in stroke
Cirstea, M. C., & Levin, M. F. (2000) · Brain · doi:10.1093/brain/123.5.940 · Cited by 1,006
Dobkin, B. H. (2005) · New England Journal of Medicine · doi:10.1056/nejmcp043511 · Cited by 910
Mobile Health Technology Evaluation
Kumar, S., Nilsen, W. J., Abernethy, A., Atienza, A., Patrick, K., Pavel, M., Riley, W. T., Shar, A., Spring, B., Spruijt-Metz, D., et al. (2013) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2013.03.017 · Cited by 900 · cited 1×
“Each subject was familiar with the operation process in advance and then performed three extension and three compensation movements, covering a wide range of shoulder and elbow arm movements [30]–[32], as shown in Figs.”
MethodVision-based human motion analysis: An overview
Poppe, R. (2007) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2006.10.016 · Cited by 835 · cited 1×
“Another method is based on a visual system [21].”
MethodComparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis
Pfister, A., West, A. M., Bronner, S., & Noah, J. A. (2014) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2014.909540 · Cited by 552 · cited 1×
“Typical marker technology, such as the Vicon system, is the gold standard for human posture recognition [22]; however, it has a high cost, marker artifacts, complex operation, and site requirements [23].”
BackgroundA method for determination of upper extremity kinematics
Rab, G., Petuskey, K., & Bagley, A. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00155-2 · Cited by 394 · cited 1×
“of the upper limbs are very complex [13],a and compensatory”
BackgroundMotor compensation and its effects on neural reorganization after stroke
Jones, T. A. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2017.26 · Cited by 377 · cited 1×
“However, long-term compensatory exercise will hinder the affected side from returning to the prestroke state, reduce the amount of movement of the necessary joints [10], and eventually cause learned disuse [11], which significantly affects the recovery of the affected limb [12] to the expected effect.”
BackgroundMechanisms of neural plasticity following brain injury
Wieloch, T., & Nikolich, K. (2006) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2006.05.011 · Cited by 349 · cited 1×
“Neural plasticity can change the structure and function of the central nervous system of stroke patients [1], including the acquisition of new skills and compensation for the loss of function before illness [2], [3].”
Background
Research works printed but not linked: 1
- Dikkers, 2005, Support vector machines in ordinal classification: An application to corporate credit scoring, Neural Netw. World, 15, 491
Cited by
Wei, S., & Wu, Z. (2023) · Sensors · doi:10.3390/s23187667 · Cited by 147
“Xu et al. [49] aimed at the detection of compensatory motion in rehabilitation exercises, and observed that the automatic compensation detection of SVM performed better than other algorithms in a normal rehabilitation exercise state.”
BackgroundMethodInfluentialNicora, G., Pe, S., Santangelo, G., Billeci, L., Aprile, I. G., Germanotta, M., Bellazzi, R., Parimbelli, E., & Quaglini, S. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01605-z · Cited by 77
“Finally, in [199], compensation in patients with dyskinesia was detected by using a trunk restraint belt, acquiring sEMG, angular displacement, and force, and applying Linear Discriminant Analysis (LDA), k-NN and SVM classifiers.”
Rocha, C., CARNEIRO, I., Torres, M., Oliveira, H. P., Pires, E. J. S., & Silva, M. F. (2025) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/adeb1e · Cited by 32
Multimodal Sensing in Stroke Motor Rehabilitation
Zhao, Z., Wang, J., Wang, S., Wang, R., Lu, Y., Yuan, Y., Chen, J., Dai, Y., Liu, Y., Wang, X., et al. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202200055 · Cited by 23
Sensor Fusion and Machine Learning for Seated Movement Detection With Trunk Orthosis
Rao, A. Z., Siddique, S. S., Mujib, M. D., Hasan, M. A., Alokaily, A. O., & Tahira, T. (2024) · IEEE Access · doi:10.1109/access.2024.3377111 · Cited by 18
“…for fall prediction in the elderly [15], trunk muscle fatigue prediction [16], automatic detection of trunk compensatory movements during seated tasks [17], [18], scoliosis classification [19], low back pain classification and risk assessment [20], [21], [22], [23], and performance in sports [24].”
BackgroundDing, K., Wang, J., Wang, X., Zhou, L., Xiong, D., & Guo, L. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3408323 · Cited by 13
“Furthermore, compared to visual sensors [18], sEMG [24], and torso restraining belts [26], IMU sensors offer a more portable, cost-effective, and convenient option for stroke patients during clinical, community, and home-based rehabilitation training.”
BackgroundMethodInfluentialChen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9
Multimodal Information Fusion for Control of Rehabilitation Robots in Motor Dysfunction: A Review
Liu, C., Wang, X., Orban, M., Vartanov, A., Elsamanty, M. M., Pan, T., & Guo, K. (2026) · Bioengineering · doi:10.3390/bioengineering13060627 · Cited by 4
“Xu et al. [116] addressed compensatory motion detection during rehabilitation by fusing sEMG, force, and angular displacement data with SVM classification, achieving 94.6% detection accuracy.”
InfluentialBenachour, Y., Flitti, F., Maloukh, L., Far, A. B., Boutellaa, E., Bentoumi, M., Rai, M. C. E., Aburaed, N., Ali, K., Rehman, M. U., et al. (2026) · IEEE Access · doi:10.1109/access.2026.3707566 · Cited by 4
Xie, L., & Li, Z. (2025) · PLoS ONE · doi:10.1371/journal.pone.0323821 · Cited by 2
“The method exhibited good performance, with an F1 score of 0.9256 for trunk forward tilt detection, 0.9190 for scapular elevation detection, and 0.826 for trunk rotation detection [20].”
InfluentialSelf-citationSmart sensor-based activity recognition for patients in healthcare
Gharsi, N., Mohammadi, K., & Shahbazi, M. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00029-6 · Cited by 2
Evaluation of s-EMG Sensor Locations for Upper-Limb Compensatory Movement Detection
Berjis, M., LeBel, M., Lizotte, D. J., & Trejos, A. L. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3663991 · Cited by 1
“Some methods also use a combination of these sensors [20], [21].”
Fan, J., Liu, J., Wang, W., Zhang, Y., Ma, X., & Zhang, J. (2025) · China Automation Congress (CAC) · doi:10.1109/cac67268.2025.11487595 · Cited by 1
“The detection solutions based on wearable devices suffer from issues such as cumbersome installation and poor stability[4].”
(2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3199223
Hwang, Y., Kim, T., Moon, J. H., Lee, A., Jeon, H. J., Kim, J., & Chun, M. H. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3689896
“Xu et al. [22] and Cai et al. [20], [21] achieved higher F1-scores ( > 0.90) using sensor-fusion or contact-based systems, but these methods require more complex hardware and, in some cases, were evaluated only on healthy participants or very small patient cohorts (e.g., two subjects in the test…”
Influential
Metadata
- Authors
- Xu, P., Xia, D., Zheng, B., Huang, L., & Xie, L.
- Affiliations
- South China University of Technology (CN)
- Third Affiliated Hospital of Sun Yat-sen University (CN)
- Venue
- IEEE Sensors Journal
- Published
- 2022-09-01
- Volume
- 22
- Issue
- 17
- Pages
- 17162-17172
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W4285818215
- Cited by
- 12
- References
- 44
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 2 · 2023: 2 · 2022: 1
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Funders
- National Natural Science Foundation of China (52075177)
- National Key Research and Development Program of China (2021YFB3301400)
- Research Foundation of Guangdong Province (2019A050505001, 2018KZDXM002)
- Guangzhou Research Foundation (202002030324, 201903010028)
- Zhongshan Research Foundation (2020B2020, 2021B2022)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- stroke rehabilitation, upper limb rehabilitation, force sensor, angular displacement sensor, surface electromyography, trunk rotation, scapular elevation, support vector machine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.