A Novel Compensatory Motion Detection Method Using Multiple Signals and Machine Learning
The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index.
Abstract
Harmful compensatory motion will seriously influence the upper limb rehabilitation effect of stroke patients. Existing compensatory motion pattern detection methods, which are mainly based on accelerometers, inertial measurement units (IMUs), and vision, have problems such as high installation requirements, calibration difficulty, object occlusion, and complex operations. To solve these problems, by analyzing the principle of compensatory motion, this paper designs a trunk restraint belt, compensation motion mode detection system that is composed of a force sensor (F-S), angular displacement sensor (AD-S), and surface electromyography (sEMG). Fifteen healthy subjects without dyskinesia completed normal motion and simulated compensatory movement modes (trunk rotation, trunk forward tilt, and scapular elevation) based on the system. Machine learning (ML) methods are used to classify three compensated motion and normal motion (NM). Among them, the support vector machine (SVM) classifier shows good classification performance for trunk forward tilt (F1-score = 0.9256), shoulder blade elevation (F1-score = 0.9190), trunk rotation (F1-score = 0.8262) and normal motion (F1-score = 0.9758). This method is a new compensation detection method with obvious advantages: it is easy to wear, and without considering the problems of calibration and target occlusion, it can not only identify the patient motion mode but also limit the large range of compensatory motion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“| IMU and sEMG | SVM | 97.6% | 1% | 273 |”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [273]
Citations
Cites
A systematic analysis of performance measures for classification tasks
Sokolova, M., & Lapalme, G. (2009) · Information Processing & Management · doi:10.1016/j.ipm.2009.03.002 · Cited by 7,515
Kolominsky-Rabas, P. L., Weber, M., Gefeller, O., Neundoerfer, B., & Heuschmann, P. U. (2001) · Stroke · doi:10.1161/hs1201.100209 · Cited by 1,281
Compensatory strategies for reaching in stroke
Cirstea, M. C., & Levin, M. F. (2000) · Brain · doi:10.1093/brain/123.5.940 · Cited by 1,006
Dobkin, B. H. (2005) · New England Journal of Medicine · doi:10.1056/nejmcp043511 · Cited by 910
Mobile Health Technology Evaluation
Kumar, S., Nilsen, W. J., Abernethy, A., Atienza, A., Patrick, K., Pavel, M., Riley, W. T., Shar, A., Spring, B., Spruijt-Metz, D., et al. (2013) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2013.03.017 · Cited by 900
Vision-based human motion analysis: An overview
Poppe, R. (2007) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2006.10.016 · Cited by 835
Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis
Pfister, A., West, A. M., Bronner, S., & Noah, J. A. (2014) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2014.909540 · Cited by 552
A method for determination of upper extremity kinematics
Rab, G., Petuskey, K., & Bagley, A. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00155-2 · Cited by 394
Motor compensation and its effects on neural reorganization after stroke
Jones, T. A. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2017.26 · Cited by 377
Mechanisms of neural plasticity following brain injury
Wieloch, T., & Nikolich, K. (2006) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2006.05.011 · Cited by 349
Interactive wearable systems for upper body rehabilitation: a systematic review
Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0229-y · Cited by 348
Kim, K. S., Choi, H. H., Moon, C. S., & Mun, C. W. (2011) · Current Applied Physics · doi:10.1016/j.cap.2010.11.051 · Cited by 331
Roby-Brami, A., Feydy, A., Combeaud, M., Biryukova, E. V., Bussel, B., & Levin, M. F. (2003) · Acta Neurologica Scandinavica · doi:10.1034/j.1600-0404.2003.00021.x · Cited by 281
Assessment of movement quality in robot- assisted upper limb rehabilitation after stroke: a review
Nordin, N., Xie, S., & Wünsche, B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-137 · Cited by 271
Ruuska, S., Hämäläinen, W., Kajava, S., Mughal, M., Matilainen, P., & Mononen, J. (2018) · Behavioural Processes · doi:10.1016/j.beproc.2018.01.004 · Cited by 246
Shaping plasticity to enhance recovery after injury
Dancause, N., & Nudo, R. J. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53355-5.00015-4 · Cited by 202
Voluntary motion support control of Robot Suit HAL triggered by bioelectrical signal for hemiplegia
Kawamoto, H., Taal, S. R., Niniss, H., Hayashi, T., Kamibayashi, K., Eguchi, K., & Sankai, Y. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626191 · Cited by 164
Cortical Plasticity during Motor Learning and Recovery after Ischemic Stroke
Hosp, J. A., & Luft, A. R. (2011) · Neural Plasticity · doi:10.1155/2011/871296 · Cited by 162
Experience-dependent neural plasticity in the adult damaged brain
Kerr, A. L., Cheng, S.-Y., & Jones, T. A. (2011) · Journal of Communication Disorders · doi:10.1016/j.jcomdis.2011.04.011 · Cited by 152
Schwerin, S. C., Dewald, J. P. A., Haztl, M., Jovanovich, S., Nickeas, M., & MacKinnon, C. D. (2007) · Experimental Brain Research · doi:10.1007/s00221-007-1169-8 · Cited by 141
Reliability and Validity of Kinect RGB-D Sensor for Assessing Standing Balance
Yang, Y., Pu, F., Li, Y., Li, S., Fan, Y., & Li, D. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2296509 · Cited by 123
Allred, R. P., & Jones, T. A. (2007) · Experimental Neurology · doi:10.1016/j.expneurol.2007.10.010 · Cited by 106
Alaverdashvili, M. (2007) · Behavioural Brain Research · doi:10.1016/j.bbr.2007.11.007 · Cited by 94
Rijntjes, M. (2006) · Current Opinion in Neurology · doi:10.1097/01.wco.0000203886.28068.38 · Cited by 93
Darling, W. G., Pizzimenti, M. A., & Morecraft, R. J. (2011) · Journal of Integrative Neuroscience · doi:10.1142/s0219635211002737 · Cited by 91
van Kordelaar, J., van Wegen, E. E. H., & Kwakkel, G. (2012) · Experimental Brain Research · doi:10.1007/s00221-012-3169-6 · Cited by 89
A Wearable Device and System for Movement and Biometric Data Acquisition for Sports Applications
Kos, M., & Kramberger, I. (2017) · IEEE Access · doi:10.1109/access.2017.2675538 · Cited by 83
Automatic Detection of Compensation During Robotic Stroke Rehabilitation Therapy
Zhi, Y. X., Lukasik, M., Li, M. H., Dolatabadi, E., Wang, R. H., & Taati, B. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2780836 · Cited by 77
Measuring functional arm movement after stroke using a single wrist-worn sensor and machine learning
Bochniewicz, E. M., Emmer, G., McLeod, A., Barth, J., Dromerick, A. W., & Lum, P. (2017) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2017.07.004 · Cited by 73 · cited 1×
“Although many studies explore such methods, there will inevitably be problems such as complicated installation, poor stability, and discomfort [20].”
BackgroundLevin, M. F., Magdalon, E. C., Michaelsen, S. M., & Quevedo, A. A. F. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2387412 · Cited by 70
Pain, L. A. M., BAKER, R. G., Richardson, D. L., & Agur, A. M. R. (2014) · Disability and Rehabilitation · doi:10.3109/09638288.2014.932450 · Cited by 61
EMG Based Control of a Robotic Exoskeleton for Shoulder and Elbow Motion Assist
Rahman, M. H., Ochoa-Luna, C., & Saad, M. (2015) · Journal of Automation and Control Engineering · doi:10.12720/joace.3.4.270-276 · Cited by 53
sEMG-Based Trunk Compensation Detection in Rehabilitation Training
Ma, K., Chen, Y., Zhang, X., Zheng, H., Yu, S., Cai, S., & Xie, L. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01250 · Cited by 53
Self-citationThe toronto rehab stroke pose dataset to detect compensation during stroke rehabilitation therapy
Dolatabadi, E., Zhi, Y. X., Ye, B., Coahran, M., Lupinacci, G., Mihailidis, A., Wang, R. H., & Taati, B. (2017) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.1145/3154862.3154925 · Cited by 51
Valdés, B. A., Schneider, A. N., & der Loos, H. F. M. V. (2017) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2017.03.034 · Cited by 49
Dunne, A., Do-Lenh, S., OLaighin, G. M., Shen, C., & Bonato, P. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626724 · Cited by 48
Célisse, A., & Mary‐Huard, T. (2015) · arXiv (Cornell University) · doi:10.48550/arxiv.1508.04905 · Cited by 45
Arm-plane representation of shoulder compensation during pointing movements in patients with stroke
Merdler, T., Liebermann, D. G., Levin, M. F., & Berman, S. (2013) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2013.03.006 · Cited by 42
Takeuchi, N., Tada, T., Chuma, T., Matsuo, Y., & Ikoma, K. (2007) · Stroke · doi:10.1161/strokeaha.106.470187 · Cited by 42
Identifying compensatory movement patterns in the upper extremity using a wearable sensor system
Ranganathan, R., Wang, R., Dong, B., & Biswas, S. K. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa9835 · Cited by 39
Lin, S., Mann, J., Mansfield, A., Wang, R. H., Harris, J. E., & Taati, B. (2019) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668319831631 · Cited by 31
Cai, S., Li, G., Huang, S., Zheng, H., & Xie, L. (2019) · IEEE Access · doi:10.1109/access.2019.2923077 · Cited by 24
Self-citationImpact of robotic exoskeleton based on electromyography for rehabilitation of post stroke patient
Utomo, B., Triwiyanto, T., Suhartini, S., Luthfiyah, S., & Mudjiono, U. (2018) · AIP conference proceedings · doi:10.1063/1.5054509 · Cited by 4
Research works printed but not linked: 1
- Dikkers, 2005, Support vector machines in ordinal classification: An application to corporate credit scoring, Neural Netw. World, 15, 491
Cited by
Wei, S., & Wu, Z. (2023) · Sensors · doi:10.3390/s23187667 · Cited by 142
Nicora, G., Pe, S., Santangelo, G., Billeci, L., Aprile, I. G., Germanotta, M., Bellazzi, R., Parimbelli, E., & Quaglini, S. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01605-z · Cited by 77
Rocha, C., CARNEIRO, I., Torres, M., Oliveira, H. P., Pires, E. J. S., & Silva, M. F. (2025) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/adeb1e · Cited by 32
Multimodal Sensing in Stroke Motor Rehabilitation
Zhao, Z., Wang, J., Wang, S., Wang, R., Lu, Y., Yuan, Y., Chen, J., Dai, Y., Liu, Y., Wang, X., et al. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202200055 · Cited by 23
Sensor Fusion and Machine Learning for Seated Movement Detection With Trunk Orthosis
Rao, A. Z., Siddique, S. S., Mujib, M. D., Hasan, M. A., Alokaily, A. O., & Tahira, T. (2024) · IEEE Access · doi:10.1109/access.2024.3377111 · Cited by 18
Metadata
- Authors
- Xu, P., Xia, D., Zheng, B., Huang, L., & Xie, L.
- Affiliations
- South China University of Technology (CN)
- Third Affiliated Hospital of Sun Yat-sen University (CN)
- Venue
- IEEE Sensors Journal
- Published
- 2022-09-01
- Volume
- 22
- Issue
- 17
- Pages
- 17162-17172
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W4285818215
- Cited by
- 12
- References
- 44
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 2 · 2023: 2 · 2022: 1
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Funders
- National Natural Science Foundation of China (52075177)
- National Key Research and Development Program of China (2021YFB3301400)
- Research Foundation of Guangdong Province (2019A050505001, 2018KZDXM002)
- Guangzhou Research Foundation (202002030324, 201903010028)
- Zhongshan Research Foundation (2020B2020, 2021B2022)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- stroke rehabilitation, upper limb rehabilitation, force sensor, angular displacement sensor, surface electromyography, trunk rotation, scapular elevation, support vector machine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.