Advances in Photonic Crystal Fiber-Based Sensor for Detection of Physical and Biochemical Parameters—A Review
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
The promising properties of photonic crystal fibers (PCFs) have sparked the interest of a number of research organizations. Due to the PCF’s air holes, liquid or gas samples can be inserted into them. This permits a well-controlled interaction between confined light and sensing samples, enabling the development of novel sensing applications. That was never conceivable with conventional optical fibers. PCF applications in sensing fields can be divided into physical sensors and biochemical sensors based on the parameter being measured. Physical sensors measure pressure, temperature, refractive index (RI), curvature, vibration, torsion, electric field, and displacement, among other physical characteristics. Biochemical sensors can detect chemical and biological (such as antibodies, cells, bacteria, enzymes, viruses, nucleic acids, etc.) substances. The measurement of the chemical RI is a crucial component of biochemical sensors. Due to their close relationship with biosensors, chemical sensors are commonly referred to as biochemical sensors. This article covers the detecting capabilities of surface plasmon resonance (SPR)-based PCF biochemical and physical sensors in addition to a variety of ways to enhance their sensing capacities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kelly, K. L., Coronado, E., Zhao, L. L., & Schatz, G. C. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp026731y · Cited by 10,594 · cited 1×
“Localized SPPs (LSPPs) are also formed when the surface of a metal nanoparticle interacts with the electromagnetic field, resulting in significant oscillations [10].”
BackgroundNotizen: Radiative Decay of Non Radiative Surface Plasmons Excited by Light
Kretschmann, E., & Raether, H. (1968) · Zeitschrift für Naturforschung A · doi:10.1515/zna-1968-1247 · Cited by 3,377 · cited 2×
“SPR is the resonant oscillation of conduction electrons at the interface of a negative permittivity material (generally metal) and a positive permittivity material (usually dielectric or air) when transverse magnetic (TM) or p-polarization light strikes a thin metal surface SPR was first discovered by Turbadar [6], bu…”
BackgroundOtto, A. (1968) · Zeitschrift für Physik A Hadrons and nuclei · doi:10.1007/bf01391532 · Cited by 3,065 · cited 6×
“[6], but it was Otto [7] and Kretschmann and Raether’s [8] work in 1968 that gave an explanation and demonstrated the adaptability of the approach.”
BackgroundInfluentialA fiber-optic chemical sensor based on surface plasmon resonance
Jorgenson, R. C., & Yee, S. S. (1993) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(93)80021-3 · Cited by 1,229
Wijaya, E., Lenaerts, C., Maricot, S., Hastanin, J., Habraken, S., Vilcot, J.-P., Boukherroub, R., & Szunerits, S. (2011) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2011.05.001 · Cited by 377 · cited 1×
“In addition, two approaches for the SPR sensor have been published, including grating configuration [13] and waveguide”
MethodPhotonic Crystal Fibers for Sensing Applications
Pinto, A. M. R., & Lopez-Amo, M. (2012) · Journal of Sensors · doi:10.1155/2012/598178 · Cited by 309
Spiral Photonic Crystal Fiber-Based Dual-Polarized Surface Plasmon Resonance Biosensor
Hasan, M. R., Akter, S., Rifat, A. A., Rana, S., Ahmed, K., Ahmed, R., Subbaraman, H., & Abbott, D. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2769720 · Cited by 298
Fu, H., Tam, H., Shao, L., Dong, X., Wai, P. K. A., Lü, C., & Khijwania, S. K. (2008) · Applied Optics · doi:10.1364/ao.47.002835 · Cited by 297
Mid-infrared surface plasmon resonance sensor based on photonic crystal fibers
Liu, C., Yang, L., Lu, X., Liu, Q., Wang, F., Lv, J., Sun, T., Mu, H., & Chu, P. K. (2017) · Optics Express · doi:10.1364/oe.25.014227 · Cited by 290
Hollow-core silver coated photonic crystal fiber plasmonic sensor
Momota, M. R., & Hasan, M. R. (2018) · Optical Materials · doi:10.1016/j.optmat.2017.12.049 · Cited by 213
Ademgil, H., & Haxha, S. (2015) · Sensors · doi:10.3390/s151229891 · Cited by 212 · cited 5×
“Schematic cross section of (a) octagonal PCF (O-PCF) [74], (b) V-PCF [75], (c) hybrid PCF (H-PCF) [76], (d) hybrid hexagonal shape PCF (H-HPCF) [77], (e) Q-PCF [78], and (f) quasi-cladding slotted core Q-PCF [79].”
BackgroundInfluentialComplete Absorption of Light by Thin Metal Films
Turbadar, T. (1959) · Proceedings of the Physical Society · doi:10.1088/0370-1328/73/1/307 · Cited by 204 · cited 1×
“[6], but it was Otto [7] and Kretschmann and Raether’s [8] work in 1968 that gave an explanation and demonstrated the adaptability of the approach.”
BackgroundSize dependence of Au NP-enhanced surface plasmon resonance based on differential phase measurement
Zeng, S., Yu, X., Law, W.-C., Zhang, Y., Hu, R., Dinh, X.-Q., Ho, H.-P., & Yong, K.-T. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.09.073 · Cited by 198 · cited 1×
“incoming beam must equal that of the plasmon [11].”
BackgroundRamanujam, N. R., Amiri, I. S., Taya, S. A., Olyaee, S., Udaiyakumar, R., Pasumpon Pandian, A., Joseph Wilson, K. S., Mahalakshmi, P., & Yupapin, P. P. (2019) · Microsystem Technologies · doi:10.1007/s00542-018-3947-6 · Cited by 171
Highly sensitive octagonal photonic crystal fiber based sensor
Ademgil, H. (2014) · Optik · doi:10.1016/j.ijleo.2014.08.018 · Cited by 169 · cited 1×
“Schematic cross section of (a) octagonal PCF (O-PCF) [74], (b) V-PCF [75], (c) hybrid PCF (H-PCF) [76], (d) hybrid hexagonal shape PCF (H-HPCF) [77], (e) Q-PCF [78], and (f) quasi-cladding slotted core Q-PCF [79].”
BackgroundPhotonic crystal biosensor for refractive index based cancerous cell detection
Panda, A., & Pukhrambam, P. D. (2020) · Optical Fiber Technology · doi:10.1016/j.yofte.2019.102123 · Cited by 143
Sensitivity Enhancement of a Surface Plasmon Resonance Sensor with Platinum Diselenide
Jia, Y., Li, Z., Wang, H., Saeed, M., & Cai, H. (2019) · Sensors · doi:10.3390/s20010131 · Cited by 135
Photonic crystal fiber-based plasmonic biosensor with external sensing approach
Aoni, R. A., Hasan, M. R., Ahmed, R., & Butt, H. (2017) · Journal of Nanophotonics · doi:10.1117/1.jnp.12.012503 · Cited by 131 · cited 2×
“[59] presented a PCF biosensor with an external sensing approach in which”
BackgroundMethodHigh pressure sensor based on photonic crystal fiber for downhole application
Fu, H. Y., Wu, C., Tse, M. L. V., Zhang, L., Cheng, K. C., Tam, H., Guan, B., & Lü, C. (2010) · Applied Optics · doi:10.1364/ao.49.002639 · Cited by 127
Paul, B. K., Ahmed, K., Dhasarathan, V., Ahmed, F., Roy, S., & Abbott, D. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2872892 · Cited by 117 · cited 5×
“Schematic cross section of (a) octagonal PCF (O-PCF) [74], (b) V-PCF [75], (c) hybrid PCF (H-PCF) [76], (d) hybrid hexagonal shape PCF (H-HPCF) [77], (e) Q-PCF [78], and (f) quasi-cladding slotted core Q-PCF [79].”
BackgroundInfluentialMitu, S. A., Ahmed, K., Al-Zahrani, F. A., Grover, A., Rajan, M. S. M., & Moni, M. A. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2021.106551 · Cited by 88 · cited 2×
“Representation of (a) PCF cross section, (b) mesh domain, and (c) cell transformation during pregnancy [31].”
BackgroundCharacterization of Pressure Response of Bragg Gratings in Grapefruit Microstructured Fibers
Wu, C., Guan, B., Wang, Z., & Feng, X. (2010) · Journal of Lightwave Technology · doi:10.1109/jlt.2010.2042277 · Cited by 81 · cited 2×
“86 pm/MPa) [65] and SHDC-PCF (−32 pm/MPa) [68], however, the hydrostatic pressure sensing range of DCDHF is only 0–100 MPa.”
BackgroundLiu, Z., Tse, M.-L. V., Wu, C., Chen, D. R., Lü, C., & Tam, H. (2012) · Optics Express · doi:10.1364/oe.20.021749 · Cited by 80 · cited 2×
“(d) Schematic representation of the setup for measuring hydrostatic pressure [67].”
BackgroundSkorobogatiy, M. A. (2009) · Journal of Sensors · doi:10.1155/2009/524237 · Cited by 78
Wang, Q., & Wang, B. (2018) · Optics & Laser Technology · doi:10.1016/j.optlastec.2018.05.006 · Cited by 72
Photonic crystal fiber-based blood components detection in THz regime: Design and simulation
Bulbul, A. A.-M., Jibon, R. H., Biswas, S., Pasha, S. T., & Sayeed, M. A. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100081 · Cited by 56
Islam, M. R., Iftekher, A. N. M., Noor, F., Khan, M. R. H., Reza, M. T., & Nishat, M. M. (2022) · Applied Physics A · doi:10.1007/s00339-021-05220-2 · Cited by 53 · cited 2×
“Cross-sectional view of AZO-coated SPR PCF [32].”
BackgroundEx-centric core photonic crystal fiber sensor with gold nanowires based on surface plasmon resonance
Liu, C., Fu, G., Wang, F., Yi, Z., Xu, C., Yang, L., Liu, Q., Liu, W., Li, X., Mu, H., et al. (2019) · Optik · doi:10.1016/j.ijleo.2019.163173 · Cited by 50
AI Algorithm for Mode Classification of PCF-SPR Sensor Design
Goswami, M., Khare, P., & Shakya, S. (2023) · Plasmonics · doi:10.1007/s11468-023-01997-5 · Cited by 49 · cited 1×
“tification, which simplifies the confinement loss calculation procedure [98].”
MethodSide-Hole Dual-Core Photonic Crystal Fiber for Hydrostatic Pressure Sensing
Hu, G., & Chen, D. R. (2012) · Journal of Lightwave Technology · doi:10.1109/jlt.2012.2198615 · Cited by 46 · cited 12×
“[68] G. Hu and D. Chen, “Side-hole dual-core photonic crystal fiber for hydrostatic pressure sensing,” J. Lightw.”
BackgroundInfluentialA Polarization-independent SPR Sensor Based on Photonic Crystal Fiber for Low RI Detection
Wang, J., Pei, L., Wu, L., Ji, W., Ruan, Z., & Zheng, J. (2019) · Plasmonics · doi:10.1007/s11468-019-01054-0 · Cited by 45 · cited 1×
“compact size, and extremely sensitive characteristics [2], [3], [4].”
BackgroundPhotonic Crystal Fiber Tip Sensor for High-Temperature Measurement
Park, B., Provine, J., Jung, I. W., Howe, R. T., & Solgaard, O. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2153844 · Cited by 38
A Polarization Filter Based on Photonic Crystal Fiber with Asymmetry Around Gold-Coated Holes
Li, H., Li, S., Chen, H., Li, J., An, G., & Zi, J. (2015) · Plasmonics · doi:10.1007/s11468-015-0023-2 · Cited by 37 · cited 2×
“It is also possible to change the resonance point and split the resonance peaks into two orthogonal polarization states by destroying the symmetry surrounding the gold-coated holes [39].”
BackgroundRefractometric THz Sensing of Blood Components in a Photonic Crystal Fiber Platform
Rahman, M. M., Mou, F. A., Bhuiyan, M. I. H., & Islam, M. R. (2022) · Brazilian Journal of Physics · doi:10.1007/s13538-022-01054-2 · Cited by 36
The performance of hosting and core materials for slotted core Q-PCF in terahertz spectrum
Kanmani, R., Ahmed, K., Roy, S., Ahmed, F., Paul, B. K., & Rajan, M. S. M. (2019) · Optik · doi:10.1016/j.ijleo.2019.163084 · Cited by 32 · cited 5×
“Schematic cross section of (a) octagonal PCF (O-PCF) [74], (b) V-PCF [75], (c) hybrid PCF (H-PCF) [76], (d) hybrid hexagonal shape PCF (H-HPCF) [77], (e) Q-PCF [78], and (f) quasi-cladding slotted core Q-PCF [79].”
BackgroundInfluentialProposal of a simple structure photonic crystal fiber for lower indexed chemical sensing
Asaduzzaman, S., Ahmed, K., Arif, M. F. H., & Morshed, M. (2015) · International Conference on Computer and Information Technology (ICCIT) · doi:10.1109/iccitechn.2015.7488055 · Cited by 25
Toward Label-Free Biosensing With Silicon Carbide: A Review
Cooper, O., Wang, B., Brown, C. L., et al. (2016) · IEEE Access · doi:10.1109/access.2016.2518190 · Cited by 23 · cited 1×
“Biochemical sensors are mainly driven by changes in the refractive indices of bio-analytes such as antibodies, antigens, viruses, proteins, and blood [20].”
BackgroundAhmed, K., Islam, M. S., & Paul, B. K. (2017) · Karbala International Journal of Modern Science · doi:10.1016/j.kijoms.2017.02.001 · Cited by 22 · cited 2×
“[77] developed a micro-cored hybrid hexagonal PCF as shown in Fig.”
BackgroundMethodHigh sensitivity photonic crystal fiber-based refractive index microbiosensor
Gandhi, M. S. A., Babu, P. R., Senthilnathan, K., & Li, Q. (2018) · Optical Fiber Technology · doi:10.1016/j.yofte.2018.09.016 · Cited by 20
PrePCF_ML: Prediction of photonic crystal fiber parameters using machine learning algorithms
Das, T. K., Hossen, M. N., Rahman, S. M., Parvin, T., Ahmed, K., & Bui, F. M. (2022) · International Conference on Advances in Electrical, Computing, Communication and Sustainable Technologies (ICAECT) · doi:10.1109/icaect54875.2022.9807968 · Cited by 7 · cited 1×
“Currently, PCF-based sensors have been effectively used with machine-learning techniques [96], [97].”
Method
Cited by
Advancements in optical fiber-based wearable sensors for smart health monitoring
Jha, R., Mishra, P., & Kumar, S. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116232 · Cited by 217
Self-citationFunctionalized Optical Microcavities for Sensing Applications
Granizo, E., Samokhvalov, P., & Nabiev, I. (2025) · Nanomaterials · doi:10.3390/nano15030206 · Cited by 12
Metadata
- Authors
- Chaudhary, V. S., Kumar, D., Pandey, B. P., & Kumar, S.
- Venue
- IEEE Sensors Journal
- Published
- 2023-01-15
- Volume
- 23
- Issue
- 2
- Pages
- 1012-1023
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W4312290002
- Cited by
- 184
- References
- 40
- FWCI
- 10.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.