A fully electronic DNA sensor with 128 positions and in-pixel A/D conversion
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
A 16 /spl times/ 8 sensor array chip for fully electronic DNA detection is presented. The sensor principle is based on an electrochemical redox cycling process. The chip is fabricated on the basis of an extended 0.5 /spl mu/m CMOS process. Each sensor site of the array chip contains a complete A/D converter with a dynamic range of five decades. The 3/spl sigma/-homogeneity of the electrical response of the sensor array is better than 6% (10/sup -11/ A to 10/sup -7/ A) and better than 20% (10/sup -12/ A to 10/sup -7/ A). Proper operation of the chip is demonstrated with electrochemical and biological experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RajanBabu, T. V. (. (2001) · Encyclopedia of Reagents for Organic Synthesis · doi:10.1002/047084289x.re001 · Cited by 2,480
A Concise Guide to cDNA Microarray Analysis
Hegde, P., Qi, R., Abernathy, K., Gay, C., Dharap, S., Gaspard, R., Hughes, J. E., Snesrud, E., Lee, N., & Quackenbush, J. (2000) · BioTechniques · doi:10.2144/00293bi01 · Cited by 947 · cited 2×
“The development of DNA microarrays in recent years has opened the way to high parallelism and high throughput [1]–[7].”
BackgroundMultiplexed biochemical assays with biological chips
Fodor, S. P. A., Rava, R. P., Huang, X. C., Pease, A. C., Holmes, C. P., & Adams, C. L. (1993) · Nature · doi:10.1038/364555a0 · Cited by 731
Biosensors and biochips: advances in biological and medical diagnostics
Vo-Dinh, T., & Cullum, B. (2000) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051549 · Cited by 509
DNA microarrays : a practical approach
Schena, M. (1999) · Oxford University Press eBooks · Cited by 222
Automation for Genomics, Part Two: Sequencers, Microarrays, and Future Trends
Meldrum, D. (2000) · Genome Research · doi:10.1101/gr.157400 · Cited by 146
Antigen detection using microelectrode array microchips
Dill, K., Montgomery, D. D., Wang, W., & Tsai, J. C. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01155-2 · Cited by 86 · cited 1×
“Whereas a number of different techniques are known to functionalize the chips [13]–[17], in our case off-chip synthesized probe molecules are deposited on the surface of the”
Fully electronic DNA detection on a CMOS chip: device and process issues
Hofmann, F., Frey, A., Holzapfl, B., Schienle, M., Paulus, C., Schindler-Bauer, P., Kuhlmeier, D., Krause, J., Hintsche, R., Nebling, E., et al. (2003) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2002.1175886 · Cited by 37 · cited 1×
“The realization of fully electronic medium-density DNA sensor array chips [8]–[10] is attracting increasing interest for diagnostic purposes.”
BackgroundSelf-citationBier, F. F., & Früste, J. P. (1997) · Experientia supplementum · doi:10.1007/978-3-0348-9043-4_7 · Cited by 19
Cited by
ISFETs in CMOS and Emergent Trends in Instrumentation: A Review
Moser, N., Lande, T. S., Toumazou, C., & Georgiou, P. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2585920 · Cited by 231
“A few solutions were proposed for the detection of these hybridisation processes on-chip, including electrochemical methods [84].”
BackgroundCMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review
Li, H., Liu, X., Li, L., Mu, X., Genov, R., & Mason, A. (2016) · Sensors · doi:10.3390/s17010074 · Cited by 198
“In other work, photolithography-defined planar gold electrodes were deposited on the CMOS surface and connected to circuitry through pre-designed surface contact pads [50,65,112,113].”
BackgroundA charge-modulated FET for detection of biomolecular processes: conception, modeling, and simulation
Barbaro, M., Bonfiglio, A., & Raffo, L. (2006) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2005.860659 · Cited by 196
“A fully electronic DNA sensor was proposed in [12]; in this paper, the problem of the readout scheme was solved by integrating electronics in the silicon substrate, however, the device is not fully compatible with a CMOS process since it makes use of gold electrodes and the transduction mechanism is based on a redox-c…”
MethodActive CMOS Sensor Array for Electrochemical Biomolecular Detection
Levine, P. M., Gong, P., Levicky, R., & Shepard, K. L. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.925407 · Cited by 195
“CMOS sensors consisting of a single on-chip WE and potentiostat have been constructed [12], much of the most recent work on integrated electrochemical sensors focuses on the integration of entire WE arrays on the same CMOS substrate as the sensor electronics [13]–[18], as shown in Fig.”
BackgroundMethodAutomated analytical microarrays: a critical review
Seidel, M., & Niessner, R. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2039-3 · Cited by 179
Metadata
- Authors
- Schienle, M., Paulus, C., Frey, A., Hofmann, F., Holzapfl, B., Schindler-Bauer, P., & Thewes, R.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2004-12
- Volume
- 39
- Issue
- 12
- Pages
- 2438-2445
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W1529995164
- Cited by
- 212
- References
- 9
- FWCI
- 10.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A fully electronic DNA sensor with 128 positions and in-pixel A/D conversion. https://app.cochat.ai/papers/10.1109/jssc.2004.837084
- The paper
- Schienle, M., Paulus, C., Frey, A., Hofmann, F., Holzapfl, B., Schindler-Bauer, P., & Thewes, R. (2004). A fully electronic DNA sensor with 128 positions and in-pixel A/D conversion. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2004.837084
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.