A CMOS smart temperature sensor with a 3/spl sigma/ inaccuracy of /spl plusmn/0.5/spl deg/C from -50/spl deg/C to 120/spl deg/C
Abstract
A low-cost temperature sensor with on-chip sigma-delta ADC and digital bus interface was realized in a 0.5 /spl mu/m CMOS process. Substrate PNP transistors are used for temperature sensing and for generating the ADC's reference voltage. To obtain a high initial accuracy in the readout circuitry, chopper amplifiers and dynamic element matching are used. High linearity is obtained by using second-order curvature correction. With these measures, the sensor's temperature error is dominated by spread on the base-emitter voltage of the PNP transistors. This is trimmed after packaging by comparing the sensor's output with the die temperature measured using an extra on-chip calibration transistor. Compared to traditional calibration techniques, this procedure is much faster and therefore reduces production costs. The sensor is accurate to within /spl plusmn/0.5/spl deg/C (3/spl sigma/) from -50/spl deg/C to 120/spl deg/C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A CMOS nested-chopper instrumentation amplifier with 100-nV offset
Bakker, A., Thiele, K., & Huijsing, J. H. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.890300 · Cited by 225
Self-citation
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Pertijs, M. A. P., Makinwa, K. A. A., & Huijsing, J. H. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858476 · Cited by 360
Self-citationMulti-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
Wang, H., & Mercier, P. P. (2017) · Scientific Reports · doi:10.1038/s41598-017-04705-6 · Cited by 43
Cai, Z., Rueda Guerrero, L. E., Louwerse, A. M. R., Suy, H., van Veldhoven, R., Makinwa, K. A. A., & Pertijs, M. A. P. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2764161 · Cited by 8
Self-citation
Metadata
- Authors
- Pertijs, M. A. P., Niederkorn, A., Ma, X., McKillop, B., Bakker, A., & Huijsing, J. H.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2005-02
- Volume
- 40
- Issue
- 2
- Pages
- 454-461
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W4247586331
- Cited by
- 367
- References
- 1
- FWCI
- 11.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A CMOS smart temperature sensor with a 3/spl sigma/ inaccuracy of /spl plusmn/0.5/spl deg/C from -50/spl deg/C to 120/spl deg/C. https://app.cochat.ai/papers/10.1109/jssc.2004.841013
- The paper
- Pertijs, M. A. P., Niederkorn, A., Ma, X., McKillop, B., Bakker, A., & Huijsing, J. H. (2005). A CMOS smart temperature sensor with a 3/spl sigma/ inaccuracy of /spl plusmn/0.5/spl deg/C from -50/spl deg/C to 120/spl deg/C. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2004.841013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.