Low-Power Successive Approximation Converter With 0.5 V Supply in 90 nm CMOS
The DOI matches its Crossref record.
Abstract
We report on the design and characterization of an ultralow-power converter, designed for use in baseband digitization in wireless sensor network radio receivers. The converter uses a successive approximation architecture and operates robustly with a supply voltage as low as 450 mV, overcoming charge leakage limitations. Implemented in a 90 nm CMOS process, this design achieves a figure of merit of 0.14 pJ/Conv.Step for the converter core and shows the integration of a complete data-conversion subsystem, including reference generation, from a 0.5 V supply.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Saberi, M., Lotfi, R., Mafinezhad, K., & Serdijn, W. A. (2011) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2011.2107214 · Cited by 236
“UCCESSIVE approximation analog-to-digital converters (SA-ADCs) have recently become very attractive in low-power moderate-resolution/moderate-speed applications such as wireless sensor nodes or implantable biomedical devices due to their minimal active analog circuit requirements and low power consumption [1]–[ 7 ].”
BackgroundHan, D., Zheng, Y., Rajkumar, R., Dawe, G. S., & Je, M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298860 · Cited by 147
“Comparing to conventional SAR ADC architectures [29]–[31], the dynamic range folding technique allows the proposed ADC to achieve the same input full scale with , which results in about 75% and 50% power reduction for the ADC digital and analog parts respectively.”
MethodRodriguez-Perez, A., Ruiz-Amaya, J., Delgado-Restituto, M., & Rodriguez-Vazquez, Á. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2187352 · Cited by 103
“suited for low-power, medium resolutions ADCs [33]–[36] and have been extensively employed for neural recording applications [6]–[10].”
BackgroundA 0.7-V 17.4-/spl mu/W 3-Lead Wireless ECG SoC
Khayatzadeh, M., Zhang, X., Tan, J., Liew, W.-S., & Lian, Y. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2279398 · Cited by 73
“On the other hand, the sampling switch with boosted turn-off [13] can be used to suppress the leakage current in the sampling switch.”
Method
Metadata
- Authors
- Gambini, S., & Rabaey, J.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2007-11
- Volume
- 42
- Issue
- 11
- Pages
- 2348-2356
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2161285838
- Cited by
- 66
- References
- 0
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-Power Successive Approximation Converter With 0.5 V Supply in 90 nm CMOS. https://app.cochat.ai/papers/10.1109/jssc.2007.906210
- The paper
- Gambini, S., & Rabaey, J. (2007). Low-Power Successive Approximation Converter With 0.5 V Supply in 90 nm CMOS. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2007.906210
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.