The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A Portable 2-Transistor Picowatt Temperature-Compensated Voltage Reference Operating at 0.5 V
Abstract
Sensing systems such as biomedical implants, infrastructure monitoring systems, and military surveillance units are constrained to consume only picowatts to nanowatts in standby and active mode, respectively. This tight power budget places ultra-low power demands on all building blocks in the systems. This work proposes a voltage reference for use in such ultra-low power systems, referred to as the 2T voltage reference, which has been demonstrated in silicon across three CMOS technologies. Prototype chips in 0.13 μm show a temperature coefficient of 16.9 ppm/°C (best) and line sensitivity of 0.033%/V, while consuming 2.22 pW in 1350 μm2. The lowest functional Vdd0.5 V. The proposed design improves energy efficiency by 2 to 3 orders of magnitude while exhibiting better line sensitivity and temperature coefficient in less area, compared to other nanowatt voltage references. For process spread analysis, 49 dies are measured across two runs, showing the design exhibits comparable spreads in TC and output voltage to existing voltage references in the literature. Digital trimming is demonstrated, and assisted one temperature point digital trimming, guided by initial samples with two temperature point trimming, enables TC <; 50 ppm/°C and ±0.35% output precision across all 25 dies. Ease of technology portability is demonstrated with silicon measurement results in 65 nm, 0.13 μm, and 0.18 μm CMOS technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design of Analog CMOS Integrated Circuits
Razavi, B. (1999) · Cited by 6,609
A CMOS bandgap reference circuit with sub-1-V operation
Banba, H., Shiga, H., Umezawa, A., Miyaba, T., Tanzawa, T., Atsumi, S., & Sakui, K. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.760378 · Cited by 908
New developments in IC voltage regulators
Widlar, R. J. (1971) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1971.1050151 · Cited by 510
A 20 mV Input Boost Converter With Efficient Digital Control for Thermoelectric Energy Harvesting
Carlson, E. J., Strunz, K., & Otis, B. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042251 · Cited by 488
A simple three-terminal IC bandgap reference
Brokaw, A. P. (1974) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1974.1050532 · Cited by 461
A 65 nm Sub-$V_{t}$ Microcontroller With Integrated SRAM and Switched Capacitor DC-DC Converter
Kwong, J., Ramadass, Y. K., Verma, N., & Chandrakasan, A. P. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2007160 · Cited by 311
A cubic-millimeter energy-autonomous wireless intraocular pressure monitor
Chen, G., Ghaed, H., Haque, R.-U., Wieckowski, M., Kim, Y., Kim, G., Fick, D., Kim, D., Seok, M., Wise, K., et al. (2011) · 2011 IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2011.5746332 · Cited by 208
Self-citationA 65nm Sub-Vt Microcontroller with Integrated SRAM and Switched-Capacitor DC-DC Converter
Kwong, J., Ramadass, Y. K., Verma, N., Koesler, M., Huber, K., Moormann, H., & Chandrakasan, A. P. (2008) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2008.4523185 · Cited by 155
Cited by
Choi, D., Lee, Y., Lin, Z.-H., Cho, S., Kim, M., Ao, C. K., Soh, S., Sohn, C., Jeong, C. K., Lee, J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12458 · Cited by 656
Wang, H., & Mercier, P. P. (2017) · Scientific Reports · doi:10.1038/s41598-017-04705-6 · Cited by 43
Metadata
- Authors
- Seok, M., Kim, G., Blaauw, D., & Sylvester, D.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2012-10
- Volume
- 47
- Issue
- 10
- Pages
- 2534-2545
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W1984863066
- Cited by
- 459
- References
- 8
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.