Compressed Sensing Analog Front-End for Bio-Sensor Applications
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In a conventional bio-sensor, key signal features are acquired using Nyquist-rate analog-to-digital conversion without exploiting the typical bio-signal characteristic of sparsity in some domain (e.g., time, frequency, etc.). Compressed sensing (CS) is a signal processing paradigm that exploits this sparsity for commensurate power savings by enabling alias-free sub-Nyquist acquisition. In a severely energy constrained sensor, CS also eliminates the need for digital signal processing (DSP). A fully-integrated low-power CS analog front-end (CS-AFE) is described for an electrocardiogram (ECG) sensor. Switched-capacitor circuits are used to achieve high accuracy and low power. Implemented in 0.13 μm CMOS in 2×3 mm2, the prototype comprises a 384-bit Fibonacci-Galois hybrid linear feedback shift register and 64 digitally-selectable CS channels with a 6-bit C-2C MDAC/integrator and a 10-bit C-2C SAR ADC in each. Clocked at 2 kHz, the total power dissipation is 28 nW and 1.8 μW for one and 64 active channels, respectively. CS-AFE enables compressive sampling of bio-signals that are sparse in an arbitrary domain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017 · cited 10×
“Satisfying RIP implies that no two values map to the same value, which enables robust reconstruction.”
BackgroundInfluentialStable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Analog-to-Information Conversion via Random Demodulation
Kirolos, S., Laska, J., Wakin, M., Duarte, M., Baron, D., Ragheb, T., Massoud, Y., & Baraniuk, R. (2006) · 2006 IEEE Dallas/CAS Workshop on Design, Applications, Integration and Software · doi:10.1109/dcas.2006.321036 · Cited by 393 · cited 2×
“[20] developed an analog-to-information converter—the random demodulator (RD)—for processing sparse multi-tone signals (Fig.”
Background
Cited by
Energy-Efficient Multi-Mode Compressed Sensing System for Implantable Neural Recordings
Suo, Y., Zhang, J., Xiong, T., Chin, P. S., Etienne-Cummings, R., & Tran, T. D. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2359180 · Cited by 47
A closed-loop compressive-sensing-based neural recording system
Zhang, J., Mitra, S., Suo, Y., Cheng, A., Xiong, T., Michon, F., Welkenhuysen, M., Kloosterman, F., Chin, P. S., Hsiao, S., et al. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036005 · Cited by 33
Pham, N., Jia, H., Tran, M., Dinh, T., Bui, N., Kwon, Y., Ma, D., Nguyen, P., Mascolo, C., & Vu, T. (2022) · Proceedings of the 28th Annual International Conference on Mobile Computing And Networking · doi:10.1145/3495243.3560533 · Cited by 12
Metadata
- Authors
- Gangopadhyay, D., Allstot, E. G., Dixon, A. M. R., Natarajan, K., Gupta, S., & Allstot, D. J.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2014-02
- Volume
- 49
- Issue
- 2
- Pages
- 426-438
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W1972967427
- Cited by
- 175
- References
- 4
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.