The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
A 48.6-to-105.2 µW Machine Learning Assisted Cardiac Sensor SoC for Mobile Healthcare Applications
Abstract
A machine-learning (ML) assisted cardiac sensor SoC (CS-SoC) is designed for mobile healthcare applications. The heterogeneous architecture realizes the cardiac signal acquisition, filtering with versatile feature extractions and classifications, and enables the higher order analysis over traditional DSPs. Besides, the asynchronous architecture with dynamic standby controller further suppresses the system active duty and the leakage power dissipation. The proposed chip is fabricated in a 90-nm standard CMOS technology and operates at 0.5 V-1.0 V (0.7 V-1.0 V for SRAM and I/O interface). Examined with healthcare monitoring applications, the CS-SoC dissipates 48.6/105.2 μW for real-time syndrome detections of ECG-based arrhythmia/VCG-based myocardial infarction with 95.8/99% detection accuracy, respectively.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The analysis of the body movements may allow diagnosing Parkinson's disease at an early stage.227”
From Wearables in Medicine (2018) · cites this paper as [227]
Citations
Cites
1-V power supply high-speed digital circuit technology with multithreshold-voltage CMOS
Mutoh, S., Douseki, T., Matsuya, Y., Aoki, T., Shigematsu, S., & Yamada, J. (1995) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.400426 · Cited by 1,123
Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526
Dual-threshold voltage techniques for low-power digital circuits
Kao, J., & Chandrakasan, A. P. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.848210 · Cited by 440
Anderson, C. W., Stolz, E. A., & Shamsunder, S. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661153 · Cited by 385
Woodward, W. A., Gray, H. L., & Elliott, A. (2011) · CRC Press eBooks · doi:10.1201/b11459 · Cited by 373
A wireless PDA-based physiological monitoring system for patient transport
Lin, Y.-H., Jan, I.-C., Ko, P. C.-I., Chen, Y.-Y., Wong, J.-M., & Jan, G.-J. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837829 · Cited by 348
Real-Time Epileptic Seizure Prediction Using AR Models and Support Vector Machines
Chisci, L., Mavino, A., Perferi, G., Sciandrone, M., Anile, C., Colicchio, G., & Fuggetta, F. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038990 · Cited by 255
ECG signal conditioning by morphological filtering
Sun, Y., Chan, K. L., & Krishnan, S. M. (2002) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(02)00034-3 · Cited by 222
Digital Filters for Real-Time ECG Signal Processing Using Microprocessors
Ahlstrom, M. L., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325589 · Cited by 189
An Energy-Efficient Biomedical Signal Processing Platform
Kwong, J., & Chandrakasan, A. P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2144450 · Cited by 120
Chang, I., Park, S. P., & Roy, K. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2036764 · Cited by 86
A voltage-scalable biomedical signal processor running ECG using 13pJ/cycle at 1MHz and 0.4V
Ashouei, M., Hulzink, J., Konijnenburg, M., Zhou, J., Duarte, F., Breeschoten, A., Huisken, J., Stuyt, J., de Groot, H., Barat, F., et al. (2011) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2011.5746341 · Cited by 75
A comparative study of wireless communication network configurations for medical applications
Arnon, S., Bhastekar, D., Kedar, D., & Tauber, A. (2003) · IEEE Wireless Communications · doi:10.1109/mwc.2003.1182112 · Cited by 71
Yoo, J., Yan, L., El-Damak, D. R., et al. (2012) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2012.6177019 · Cited by 67
A 0.09 $\mu$ W Low Power Front-End Biopotential Amplifier for Biosignal Recording
Tseng, Y., Ho, Y., Kao, S.-T., & Su, C. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2188029 · Cited by 66
Self-citationA sub-100µW multi-functional cardiac signal processor for mobile healthcare applications
Hsu, S.-Y., Ho, Y., Tseng, Y., Lin, T. Y., Chang, P.-Y., Lee, J.-W., Hsiao, J.-H., Chuang, S.-M., Yang, T.-Z., Liu, P.-C., et al. (2012) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2012.6243837 · Cited by 25
Self-citationValentian, A., & Beigné, É. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.922710 · Cited by 23
A vectorcardiogram-based classification system for the detection of Myocardial infarction
Huang, C.-S., Ko, L., Lu, S.-W., Chen, S., & Lin, C. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090220 · Cited by 15
A 48.6-to-105.2µW machine-learning assisted cardiac sensor SoC for mobile healthcare monitoring
Hsu, S.-Y., Ho, Y., Chang, P.-Y., Hsu, P.-Y., Yu, C.-Y., Tseng, Y., Yang, T.-Z., Yang, T.-F., Chen, R., Su, C., et al. (2013) · Cited by 13
Self-citationLin, W.-H., Wong, M. Y. M., Pu, L., & Zhang, Y. (2010) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2010.5627195 · Cited by 12
Chen, J.-S., Yeh, C., & Wang, J. (2013) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2013.6487799 · Cited by 10
Sung, W.-H., Hsu, S.-Y., Yu, J.-Y., Yu, C.-Y., & Lee, C. (2010) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2010.5560330 · Cited by 9
Self-citationOverview of recent advances in hardware implementation of mathematical morphology
Bartovský, J., Holik, M., Kraus, V., Krutina, A., Salom, R., & Georgiev, V. (2012) · Telecommunications Forum (TELFOR) · doi:10.1109/telfor.2012.6419292 · Cited by 2
Research works printed but not linked: 2
- zhang, 2012, A batteryless 19 <formula formulatype="inline"><tex Notation="TeX">$\mu$</tex> </formula>W MICS/ISM-band energy harvesting body area sensor node SoC, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 298
- 1995, The PTB Diagnostic ECG Database
Cited by
Significance of machine learning in healthcare: Features, pillars and applications
Javaid, M., Haleem, A., Pratap Singh, R., Suman, R., & Rab, S. (2022) · International Journal of Intelligent Networks · doi:10.1016/j.ijin.2022.05.002 · Cited by 641
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Metadata
- Authors
- Hsu, S.-Y., Ho, Y., Chang, P.-Y., Su, C., & Lee, C.-Y.
- Affiliations
- National Yang Ming Chiao Tung University (TW)
- National Dong Hwa University (TW)
- ORCID
- Lee, Chen-Yi
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2014-04
- Volume
- 49
- Issue
- 4
- Pages
- 801-811
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2080722785
- Cited by
- 82
- References
- 23
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 6 · 2023: 9 · 2022: 10 · 2021: 6 · 2020: 11 · 2019: 6 · 2018: 6 · 2017: 10 · 2016: 3 · 2015: 5
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- machine learning hardware, low-power SoC, mobile health, ECG arrhythmia detection, feature extraction, asynchronous architecture, leakage power reduction, heterogeneous architectures, 90 nm CMOS
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.