The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Micro-Power EEG Acquisition SoC With Integrated Feature Extraction Processor for a Chronic Seizure Detection System
Open accessAbstract
This paper presents a low-power SoC that performs EEG acquisition and feature extraction required for continuous detection of seizure onset in epilepsy patients. The SoC corresponds to one EEG channel, and, depending on the patient, up to 18 channels may be worn to detect seizures as part of a chronic treatment system. The SoC integrates an instrumentation amplifier, ADC, and digital processor that streams features-vectors to a central device where seizure detection is performed via a machine-learning classifier. The instrumentation-amplifier uses chopper-stabilization in a topology that achieves high input-impedance and rejects large electrode-offsets while operating at 1 V; the ADC employs power-gating for low energy-per-conversion while using static-biasing for comparator precision; the EEG feature extraction processor employs low-power hardware whose parameters are determined through validation via patient data. The integration of sensing and local processing lowers system power by 14× by reducing the rate of wireless EEG data transmission. Feature vectors are derived at a rate of 0.5 Hz, and the complete one-channel SoC operates from a 1 V supply, consuming 9 ¿ J per feature vector.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
Cited by
A Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection
Qian, C., Parramon, J., & Sanchez-Sinencio, E. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2126370 · Cited by 145
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
Abdelhalim, K., Jafari, H. M., Kokarovtseva, L., Velazquez, J. L. P., & Genov, R. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2272952 · Cited by 124
A 1-V 0.25- $\mu \text{W}$ Inverter Stacking Amplifier With 1.07 Noise Efficiency Factor
Shen, L., Lu, N., & Sun, N. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2786724 · Cited by 101
A 48.6-to-105.2 µW Machine Learning Assisted Cardiac Sensor SoC for Mobile Healthcare Applications
Hsu, S.-Y., Ho, Y., Chang, P.-Y., Su, C., & Lee, C.-Y. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2297406 · Cited by 82
Metadata
- Authors
- Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2010-04
- Volume
- 45
- Issue
- 4
- Pages
- 804-816
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2169766445
- Cited by
- 526
- References
- 2
- FWCI
- 24.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Micro-Power EEG Acquisition SoC With Integrated Feature Extraction Processor for a Chronic Seizure Detection System. https://app.cochat.ai/papers/10.1109/jssc.2010.2042245
- The paper
- Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010). A Micro-Power EEG Acquisition SoC With Integrated Feature Extraction Processor for a Chronic Seizure Detection System. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2010.2042245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.