A 1.1 nW Energy-Harvesting System with 544 pW Quiescent Power for Next-Generation Implants
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper presents a nW power management unit (PMU) for an autonomous wireless sensor that sustains itself by harvesting energy from the endocochlear potential (EP), the 70-100 mV electrochemical bio-potential inside the mammalian ear. Due to the anatomical constraints inside the inner ear, the total extractable power from the EP is limited to 1.1-6.25 nW. A nW boost converter is used to increase the input voltage (30-55 mV) to a higher voltage (0.8 to 1.1 V) usable by CMOS circuits in the sensor. A pW Charge Pump circuit is used to minimize the leakage in the boost converter. Further, ultra-low-power control circuits consisting of digital implementations of input impedance adjustment circuits and Zero Current Switching circuits along with Timer and Reference circuits keep the quiescent power of the PMU down to 544 pW. The designed boost converter achieves a peak power conversion efficiency of 56%. The PMU can sustain itself and a duty-cyled ultra-low power load while extracting power from the EP of a live guinea pig. The PMU circuits have been implemented on a 0.18µm CMOS process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design of Analog CMOS Integrated Circuits
Razavi, B. (1999) · Cited by 6,609
Leakage current mechanisms and leakage reduction techniques in deep-submicrometer CMOS circuits
Roy, K., Mukhopadhyay, S., & Mahmoodi-Meimand, H. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2002.808156 · Cited by 2,368 · cited 1×
“sees a negative source to gate voltage which helps reduces subthreshold leakage current in the transistor [17] by biasing it to the super cutoff region.”
Analysis and Optimization of Switched-Capacitor DC–DC Converters
Seeman, M. D., & Sanders, S. R. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915182 · Cited by 1,053 · cited 1×
“8 Hz, it operates well within its slow-switching limit [25].”
Vullers, R. J. M., van Schaijk, R., Doms, I., Van Hoof, C., & Mertens, R. (2009) · Solid-State Electronics · doi:10.1016/j.sse.2008.12.011 · Cited by 886 · cited 1×
“Traditional energy harvesters like photo-voltaic cells, thermoelectric generators, and piezoelectric harvesters as described in [5] are not ideal for implantable electronics since these energy sources require conditions that typically do not exist inside a mammalian body.”
A Battery-Less Thermoelectric Energy Harvesting Interface Circuit With 35 mV Startup Voltage
Ramadass, Y. K., & Chandrakasan, A. P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2074090 · Cited by 578
Self-citationBandyopadhyay, S., & Chandrakasan, A. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2197239 · Cited by 562 · cited 5×
“Previous work [16] has shown that for boost converters in DCM, operating with a high voltage-conversion ratio, the input impedance (ratio of input voltage to average input current) is approximately given by”
InfluentialSelf-citationA 20 mV Input Boost Converter With Efficient Digital Control for Thermoelectric Energy Harvesting
Carlson, E. J., Strunz, K., & Otis, B. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042251 · Cited by 488
A high-efficiency CMOS voltage doubler
Favrat, P., Deval, P., & Declercq, M. J. (1998) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.661206 · Cited by 414 · cited 1×
“As discussed before in Section III-B, a charge pump circuit (implemented as a voltage doubler) [24] is used to create an auxiliary power supply, ( 1.”
Im, J., Wang, S., Ryu, S., & Cho, G. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2225734 · Cited by 255
Trends in cardiac pacemaker batteries.
Mallela, V. S., Ilankumaran, V., & Rao, N. S. (2004) · PubMed · Cited by 253
Cited by
Thermoelectricity for IoT – A review
Haras, M., & Skotnicki, T. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.10.013 · Cited by 368
Enabling Practical Backscatter Communication for On-body Sensors
ZHANG, P., Rostami, M., Hu, P., & Ganesan, D. (2016) · Proceedings of the 2016 ACM SIGCOMM Conference · doi:10.1145/2934872.2934901 · Cited by 323
Metadata
- Authors
- Bandyopadhyay, S., Mercier, P. P., Lysaght, A. C., Stankovic, K. M., & Chandrakasan, A. P.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2014-12
- Volume
- 49
- Issue
- 12
- Pages
- 2812-2824
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2056420692
- Cited by
- 174
- References
- 19
- FWCI
- 10.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.