A Multimodal CMOS MEA for High-Throughput Intracellular Action Potential Measurements and Impedance Spectroscopy in Drug-Screening Applications
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Multi-electrode arrays (MEAs) are a candidate technology to screen cardiotoxicityin vitrobecause they enable noninvasive recording of cardiac beating rate, electrical field potential duration, and other parameters. In this paper, we present an active MEA chip featuring 16 384 electrodes, 1024 simultaneous readout channels, and 64 stimulation units (SUs) to enable six different cell-interfacing modalities: extracellular and intracellular recording, current and voltage stimulation, fast impedance motoring, and impedance spectroscopy (IS). The chip was designed and fabricated in a 0.13-$\mu \text{m}$Al CMOS technology, and the electrodes were fabricated on top of the silicon substrate using biocompatible TiN. Measurement results show a total input-referred noise of$7.5 \pm 0.6~\mu \text{V}_{\mathrm{rms}}$and$12.0 \pm 2.4~\mu \text{V}_{\mathrm {rms}}$for the action potential and full bands, respectively, with a total power consumption of 95 mW for 1024 readout channels. We have experimentally validated the CMOS MEA inin vitroexperiments, demonstrating all the different modalities. This novel platform will potentially enable high-throughput electrical activity monitoring and drug screening of cardiomyocytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drug Discovery: A Historical Perspective
Drews, J. (2000) · Science · doi:10.1126/science.287.5460.1960 · Cited by 2,760
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Hildebrandt, C., Büth, H., Cho, S., Impidjati, & Thielecke, H. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.007 · Cited by 95 · cited 2×
“IS is considered a powerful tool for noninvasive monitoring of cellular processes [21].”
BackgroundMethod
Cited by
Yuan, X., Hierlemann, A., & Frey, U. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3066043 · Cited by 50
“…PM C Funders A uthor M anuscripts Table 1 Comparison To State-Of-The-Art In Vitro CMOS-Based MEA Systems Reference Dragas ’17 [9] Ballini ’14 [14] Lopez ’18 [16] Abbott’20 [17] Tsai’17 [21] This work Mode SM SM SM APS APS SM APS Technology [μm] 0.18 0.35 0.13 0.18 0.18 0.18 Die size [mm2] 12 ×…”
BackgroundMethodInfluentialHigh-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Energy efficient neural stimulator with dynamic supply modulation
Samiei, A., & Hashemi, H. (2021) · Electronics Letters · doi:10.1049/ell2.12024 · Cited by 4
Metadata
- Authors
- Lopez, C. M., Chun, H. S., Wang, S., Berti, L., Putzeys, J., Van Den Bulcke, C., Weijers, J.-W., Firrincieli, A., Reumers, V., Braeken, D., & Van Helleputte, N.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2018-11
- Volume
- 53
- Issue
- 11
- Pages
- 3076-3086
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2892271309
- Cited by
- 99
- References
- 3
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Multimodal CMOS MEA for High-Throughput Intracellular Action Potential Measurements and Impedance Spectroscopy in Drug-Screening Applications. https://app.cochat.ai/papers/10.1109/jssc.2018.2863952
- The paper
- Lopez, C. M., Chun, H. S., Wang, S., Berti, L., Putzeys, J., Van Den Bulcke, C., Weijers, J.-W., Firrincieli, A., Reumers, V., Braeken, D., & Van Helleputte, N. (2018). A Multimodal CMOS MEA for High-Throughput Intracellular Action Potential Measurements and Impedance Spectroscopy in Drug-Screening Applications. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2018.2863952
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.