CoChat

A Fully Integrated 16-Channel Closed-Loop Neural-Prosthetic CMOS SoC With Wireless Power and Bidirectional Data Telemetry for Real-Time Efficient Human Epileptic Seizure Control

Cheng, Cheng-Hsiang, Tsai, Ping-Yuan, Yang, Tzu-Yi, Cheng, Wan-Hsueh, Yen, Ting-Yang, Luo, Zhicong, Qian, Xin-Hong, Chen, Zhi-Xin, Lin, Tzu-Han, Chen, Wei-Hong, Chen, Wei-Ming, Liang, Sheng-Fu, Shaw, Fu-Zen, Chang, Cheng-Siu, Hsin, Yue-Loong, Lee, Chen-Yi, Ker, Ming-Dou, Wu, Chung-Yu · 2018 · IEEE Journal of Solid-State Circuits
Cited by 143

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A 16-channel closed-loop neuromodulation system-on-chip (SoC) for human epileptic seizure control is proposed and designed. In the proposed SoC, a 16-channel neural-signal acquisition unit (NSAU), a biosignal processor (BSP), a 16-channel high-voltage-tolerant stimulator (HVTS), and wireless power and bidirectional data telemetry are designed. In the NSAU, the input protection circuit is used to prevent MOSFET from overstressing by the high-voltage stimulations. Hence, NSAUs can share electrodes with stimulators. The auto-reset chopper-stabilized capacitive-coupled instrumentation amplifiers (AR-CSCCIAs) are designed with the chopper-stabilized technique with a new offset reduction loop. The measured input-referred noise is 2.09 μVrmsand the noise-efficiency factor (NEF) is 3.78. The entropy-and-spectrum seizure detection algorithm is implemented in the BSP with 0.76-s seizure detection latency and 97.8% detection accuracy. When the seizure onset is detected by the BSP, the HVTS with adaptive supply control delivers 0.5-3-mA biphasic current stimulation to suppress the seizure onset. The proposed SoC is powered wirelessly, and the bidirectional data telemetry is realized through the same pair of coils in 13.56 MHz. The downlink data rate is 211 Kb/s with the binary phase-shift keying (BPSK) modulation and a new BPSK demodulator. The uplink data rate is 106 Kb/s with the load-shift keying (LSK) modulation. The proposed SoC is fabricated in a 0.18-μm CMOS technology and occupies 25 mm2. Electrical tests have been performed to characterize the SoC performance. In vivo animal experiments using mini-pigs have been performed to successfully verify the closed-loop neuromodulation functions on epileptic seizure suppression.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jssc.2018.2867293

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 143

Metadata

Authors
Cheng, C.-H., Tsai, P.-Y., Yang, T.-Y., Cheng, W.-H., Yen, T.-Y., Luo, Z., Qian, X.-H., Chen, Z.-X., Lin, T.-H., Chen, W.-H., Chen, W.-M., Liang, S.-F., Shaw, F.-Z., Chang, C.-S., Hsin, Y.-L., Lee, C.-Y., Ker, M.-D., & Wu, C.-Y.
Venue
IEEE Journal of Solid-State Circuits
Published
2018-11
Volume
53
Issue
11
Pages
3314-3326
ISSN
  • 0018-9200 (ISSN-L)
  • 1558-173X
OpenAlex
W2890191974
Cited by
143
References
1
FWCI
4.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.