Cited by 12Analog and Mixed-Signal Circuit DesignRadio Frequency Integrated Circuit DesignLow-power high-performance VLSI design

A Fully Integrated Stimulator With High Stimulation Voltage Compliance Using Dynamic Bulk Biasing Technique in a Bulk CMOS Technology

Zhou, Yixin, Wang, Keping, Yin, Simeng, Li, Wen-Yuan, Meng, Fanyi, Wang, Zhi-Gong, Ma, Kaixue·2024·IEEE Transactions on Circuits and Systems I: Regular Papers

Abstract

This paper presents a fully integrated stimulator using a dynamic bulk biasing technique and a dynamic control scheme in a 180-nm bulk CMOS technology. Unlike the conventional bulk biasing method, the bulk bias voltage is dynamically set according to the different stimulation phases. It avoids the underlying leakage current paths, and improves the maximum stimulation voltage compliance (MSVC). Together with dynamic bulk biasing scheme, a high voltage interface is designed to overcome the limitation of the breakdown voltage of the substrate diode ( V$_{\mathbf{BD}}$) between the high and low voltage domains. An all-NMOS dynamic charge pump is also proposed as a dynamic power supply above V$_{\mathbf{BD}}$and provides dynamic bulk-biasing voltages. Fabricated in a 180-nm standard CMOS technology, the stimulator achieves an MSVC of$\pm$16.5 V under a 3.3-V supply, and the achieved MSVC is$\sim$1.11 times higher than the V$_{\mathbf{BD}}$($\sim$14.8 V) of the substrate diode. The stimulator is also measured in a continuous output test mode for over 10 million cycles, the variation of$\vert$MSVC$\vert$is less than 200 mV.

Integrity signals

Registry

Crossref · 10.1109/tcsi.2024.3376370

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Dynamic bulk biasing techniques have been studied to enable a higher stimulator compliance voltage that is not limited by the diode breakdown level with the aid of charge pumps.

    “In addition to the implementation of thick-oxide devices to achieve a fully isolated active output [140], [150], dynamic bulk biasing techniques have been studied to enable a higher stimulator compliance voltage [151] that is not limited by the diode breakdown level with the aid of charge pumps [152].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhou, Y., Wang, K., Yin, S., Li, W.-Y., Meng, F., Wang, Z.-G., & Ma, K.
Affiliations
  • Southeast University (CN)
  • Tianjin University (CN)
  • Institute of RF- and OE-ICs, Southeast University, Nanjing, China
Venue
IEEE Transactions on Circuits and Systems I: Regular Papers
Published
2024-06
Volume
71
Issue
6
Pages
2525-2537
ISSN
  • 1549-8328 (ISSN-L)
  • 1558-0806
OpenAlex
W4393139857
Cited by
12
References
41
Citations by year
2026: 2 · 2025: 7 · 2024: 3
FWCI
1.32
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Circuits and Systems I Regular Papers (publishedVersion)
Funders
  • National Natural Science Funds of China (62371332, 61774035)
  • Natural Science Foundation of Jiangsu Province (BK20191260)
  • Tianjin University and the Agilic Joint Laboratory
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
Keywords
bulk CMOS, leakage current

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review