Cited by 90Wireless Body Area NetworksWireless Power Transfer SystemsNeuroscience and Neural Engineering

A Power and Data Link for a Wireless-Implanted Neural Recording System

Rush, A. D., Troyk, P. R.·2012·IEEE Transactions on Biomedical Engineering

Abstract

A wireless cortical neural recording system with a miniature-implanted package is needed in a variety of neuroscience and biomedical applications. Toward that end, we have developed a transcutaneous two-way communication and power system for wireless neural recording. Wireless powering and forward data transmission (into the body) at 1.25 Mbps is achieved using a frequency-shift keying modulated class E converter. The reverse telemetry (out of the body) carrier frequency is generated using an integer-N phase-locked loop, providing the necessary wideband data link to support simultaneous reverse telemetry from multiple implanted devices on separate channels. Each channel is designed to support reverse telemetry with a data rate in excess of 3 Mbps, which is sufficient for our goal of streaming 16 channels of raw neural data. We plan to incorporate this implantable power and telemetry system in a 1-cm diameter single-site cortical neural recording implant.

Integrity signals

Registry

Crossref · 10.1109/tbme.2012.2214385

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wireless versions of the UEA and other systems have been developed, but these prototype systems are not yet sufficiently robust for clinical use.

    “A clinical cortical visual prosthesis would be expected to use wireless actuation of the electrode arrays, and although wireless versions of the UEA and other systems have been developed (31, 50, 51), these prototype systems are not yet sufficiently robust for clinical use.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rush, A. D., & Troyk, P. R.
Affiliations
Illinois Institute of Technology (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
2012-11
Volume
59
Issue
11
Pages
3255-3262
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2052410984
Cited by
90
References
25
Citations by year
2026: 3 · 2025: 3 · 2024: 3 · 2023: 3 · 2022: 15 · 2021: 12 · 2020: 9 · 2019: 5 · 2018: 5 · 2017: 8 · 2016: 6 · 2015: 6 · 2014: 10 · 2013: 1
FWCI
3.10
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
wireless neural recording, wireless power transfer, class-E converter, frequency shift keying, phase-locked loop, cortical recording
MeSH terms
Adult, Animals, Diagnostic Techniques, Neurological, Electrodes, Implanted, Electronics, Medical, Equipment Design, Humans, Male, Neurology, Telemetry, Wireless Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review