A Power and Data Link for a Wireless-Implanted Neural Recording System
Abstract
A wireless cortical neural recording system with a miniature-implanted package is needed in a variety of neuroscience and biomedical applications. Toward that end, we have developed a transcutaneous two-way communication and power system for wireless neural recording. Wireless powering and forward data transmission (into the body) at 1.25 Mbps is achieved using a frequency-shift keying modulated class E converter. The reverse telemetry (out of the body) carrier frequency is generated using an integer-N phase-locked loop, providing the necessary wideband data link to support simultaneous reverse telemetry from multiple implanted devices on separate channels. Each channel is designed to support reverse telemetry with a data rate in excess of 3 Mbps, which is sufficient for our goal of streaming 16 channels of raw neural data. We plan to incorporate this implantable power and telemetry system in a 1-cm diameter single-site cortical neural recording implant.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Wireless versions of the UEA and other systems have been developed, but these prototype systems are not yet sufficiently robust for clinical use.
“A clinical cortical visual prosthesis would be expected to use wireless actuation of the electrode arrays, and although wireless versions of the UEA and other systems have been developed (31, 50, 51), these prototype systems are not yet sufficiently robust for clinical use.”
From Visual percepts evoked with an intracortical 96-channel microelectrode array inserted in human occipital cortex (2021) · cites this paper as [51]
Cites
Low-jitter process-independent DLL and PLL based on self-biased techniques
Maneatis, J. G. (1996) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1996.542317 · Cited by 793 · see citing works
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 336 · see citing works
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241 · see citing works
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220 · see citing works
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218 · see citing works
Chronic response of adult rat brain tissue to implants anchored to the skull
Kim, Y. T., Hitchcock, R. W., Bridge, M. J., & Tresco, P. A. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.010 · Cited by 214 · see citing works
Wireless Neural Recording With Single Low-Power Integrated Circuit
Harrison, R. R., Kier, R. J., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S. I., Greger, B. E., Solzbacher, F., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023298 · Cited by 209 · see citing works
Inductor Modeling in Wireless Links for Implantable Electronics
Yang, Z., Liu, W.-T., & Basham, E. (2007) · IEEE transactions on magnetics · doi:10.1109/tmag.2007.904189 · Cited by 198 · see citing works
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174 · see citing works
Miranda, H. C., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H. Y. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2044573 · Cited by 161 · see citing works
Thickness of the normal skull in the American blacks and whites
Adeloye, A., Kattan, K. R., & Silverman, F. N. (1975) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330430105 · Cited by 150 · see citing works
Nurmikko, A. V., Donoghue, J. P., Hochberg, L. R., Patterson, W. R., Song, Y., Bull, C. W., Borton, D. A., Laiwalla, F., Park, S., Yin, M., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038949 · Cited by 128 · see citing works
Manola, L., Roelofsen, B. H., Holsheimer, J., Marani, E., & Geelen, J. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345810 · Cited by 121 · see citing works
Lee, S. B., Lee, H., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2010.5434028 · Cited by 121 · see citing works
A Dual Band Wireless Power and Data Telemetry for Retinal Prosthesis
Wang, G., Liu, W., Sivaprakasam, M., et al. (2006) · doi:10.1109/iembs.2006.260470 · Cited by 109 · see citing works
Troyk, P. R., & DeMichele, G. A. (2004) · doi:10.1109/iembs.2003.1280869 · Cited by 74 · see citing works
Self-citationRennaker, R. L., Ruyle, A. M., Street, S. E., & Sloan, A. M. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.07.018 · Cited by 28 · see citing works
Skin flap thickness in cochlear implant patients — a prospective study
Raine, C. H., Lee, C. A., Strachan, D., et al. (2007) · Cochlear Implants International · doi:10.1179/cim.2007.8.3.148 · Cited by 26 · see citing works
Modeling and optimization of printed spiral coils in air and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333876 · Cited by 17 · see citing works
Inductive link design for miniature implants
Troyk, P. R., & Rush, A. D. (2009) · doi:10.1109/iembs.2009.5333621 · Cited by 16 · see citing works
Self-citationSkin flap thickness in cochlear implant patients – a prospective study
Raine, C. H., Lee, C. A., Strachan, D., et al. (2007) · Cochlear Implants International · doi:10.1002/cii.335 · Cited by 8 · see citing works
Dual inductive link coil design for a neural recording system
Rush, A. M., & Troyk, P. R. (2011) · doi:10.1109/iembs.2011.6091579 · Cited by 7 · see citing works
Self-citationPower and data for a wireless implanted neural recording system
Rush, A., & Troyk, P. R. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910597 · Cited by 5 · see citing works
Self-citationElectronic performance of a dual inductive link for a wireless neural recording implant
Rush, A. M., & Troyk, P. R. (2011) · doi:10.1109/iembs.2011.6091567 · Cited by 3 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Fernández, E., Alfaro, A., Soto-Sánchez, C., Gonzalez-Lopez, P., Lozano, A. M., Peña, S., Grima, M. D., Rodil, A., Gómez, B., Chen, X., et al. (2021) · Journal of Clinical Investigation · doi:10.1172/jci151331 · Cited by 250 · see citing works
Frederick, R. A., Troyk, P. R., & Cogan, S. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2bb8 · Cited by 7 · see citing works
Self-citation
- Authors
- Rush, A. D., & Troyk, P. R.
- Affiliations
- Illinois Institute of Technology (US)
- ORCID
- Troyk, P. R.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-11
- Volume
- 59
- Issue
- 11
- Pages
- 3255-3262
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2052410984
- Cited by
- 90
- References
- 25
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 3 · 2023: 3 · 2022: 15 · 2021: 12 · 2020: 9 · 2019: 5 · 2018: 5 · 2017: 8 · 2016: 6 · 2015: 6 · 2014: 10 · 2013: 1
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- wireless neural recording, wireless power transfer, class-E converter, frequency shift keying, phase-locked loop, cortical recording
- MeSH terms
- Adult, Animals, Diagnostic Techniques, Neurological, Electrodes, Implanted, Electronics, Medical, Equipment Design, Humans, Male, Neurology, Telemetry, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review