The DOI matches its Crossref record; 29 of the 31 references it cites were found in a registry or an index.
High-Value Tunable Pseudo-Resistors Design
Open accessAbstract
Pseudo-resistor circuits are used to mimic large value resistors and base their success on the reduction of occupied areas with respect to physical devices of equal value. This article presents an optimized architecture of pseudo-resistor, made in standard CMOS 0.35 μm technology to bias a low-noise transimpedance amplifier for high-sensitivity applications in the frequency range 100 kHz-10 MHz. The architecture was selected after a critical review of the different topologies to implement high-value resistances with MOSFET transistors, considering their performance in terms of linearity of response, symmetric dynamic range, frequency behavior, and simplicity of realization. The resulting circuit consumes an area of 0.017 mm2and features a tunable resistance from 20 MΩ to 20 GΩ, dynamic offset reduction due to a more than linear I-V curve, and a high-frequency noise well below the one of a physical resistor of equal value. This latter aspect highlights the larger perspective of pseudo-resistors as building blocks in very low-noise applications in addition to the advantage in occupied areas they provide.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Thermal Agitation of Electric Charge in Conductors
Nyquist, H. (1928) · Physical Review · doi:10.1103/physrev.32.110 · Cited by 3,264
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Integrated nanopore sensing platform with sub-microsecond temporal resolution
Rosenstein, J. K., Wanunu, M., Merchant, C. A., Drndić, M., & Shepard, K. L. (2012) · Nature Methods · doi:10.1038/nmeth.1932 · Cited by 506
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414
White noise in MOS transistors and resistors
Sarpeshkar, R., Delbrück, T., & Mead, C. (1993) · IEEE Circuits and Devices Magazine · doi:10.1109/101.261888 · Cited by 282
CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review
Li, H., Liu, X., Li, L., Mu, X., Genov, R., & Mason, A. J. (2016) · Sensors · doi:10.3390/s17010074 · Cited by 201
Transimpedance Amplifier for High Sensitivity Current Measurements on Nanodevices
Ferrari, G., Gozzini, F., Molari, A., & Sampietro, M. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2016998 · Cited by 198
Self-citationOn the design and characterization of femtoampere current-mode circuits
Linares-Barranco, B., & Serrano‐Gotarredona, T. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814415 · Cited by 190
Adaptive photoreceptor with wide dynamic range
Delbrück, T., & Mead, C. (2002) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.1994.409266 · Cited by 188
OlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181
Cited by
Sorted by citations
Wu, H., Chen, J., Liu, X., Zou, W., Yang, J., & Sawan, M. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3293492 · Cited by 45
Zhang, W., Yu, X., Wang, Y., Zhan, X., Zhang, H., Di, X., Yin, L., Zhang, H., Fu, Q., Yin, L., et al. (2025) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2025.3583902 · Cited by 40
A Compact Sub-μW CMOS ECG Amplifier With 57.5-MΩ Zin, 2.02 NEF, 8.16 PEF and 83.24-dB CMRR
Sawigun, C., & Thanapitak, S. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3086182 · Cited by 35
Vafaei, M., Parhizgar, A., Abiri, E., & Salehi, M. R. (2021) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2021.154005 · Cited by 26
Analog Front-End Input-Impedance Boosting Techniques for Bio-Potential Monitoring—A Review
Yan, F., & Liu, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3370766 · Cited by 25
Metadata
- Authors
- Guglielmi, E., Toso, F., Zanetto, F., Sciortino, G., Mesri, A., Sampietro, M., & Ferrari, G.
- Affiliations
- Politecnico di Milano (IT)
- ORCID
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2020-08
- Volume
- 55
- Issue
- 8
- Pages
- 2094-2105
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W3008212765
- Cited by
- 114
- References
- 31
- Citations by year
- 2026: 15 · 2025: 20 · 2024: 23 · 2023: 20 · 2022: 15 · 2021: 17 · 2020: 3
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion, other-oa)
- Funders
- EU projects ICT-STREAMS (688172)
- TRAINING4CRM (H2020, 722779)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
- Keywords
- pseudo-resistor, high-value resistors, transimpedance amplifier, low-noise circuits, CMOS circuit design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review