Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.

Zou, Xiaodan, Xu, Xiaoyuan, Yao, Libin, Lian, Yong · 2009 · IEEE Journal of Solid-State Circuits

Abstract

This paper presents a fully integrated programmable biomedical sensor interface chip dedicated to the processing of various types of biomedical signals. The chip, optimized for high power efficiency, contains a low noise amplifier, a tunable bandpass filter, a programmable gain stage, and a successive approximation register analog-to-digital converter. A novel balanced tunable pseudo-resistor is proposed to achieve low signal distortion and high dynamic range under low voltage operations. A 53 nW, 30 kHz relaxation oscillator is included on-chip for low power consumption and full integration. The design was fabricated in a 0.35 mum standard CMOS process and tested at 1 V supply. The analog front-end has measured frequency response from 4.5 mHz to 292 Hz, programmable gains from 45.6 dB to 60 dB, input referred noise of 2.5 muVrmsin the amplifier bandwidth, a noise efficiency factor (NEF) of 3.26, and a low distortion of less than 0.6% with full voltage swing at the ADC input. The system consumes 445 nA in the 31 Hz narrowband mode for heart rate detection and 895 nA in the 292 Hz wideband mode for ECG recording.

Overview

Integrity signals

Registry

Crossref · 10.1109/jssc.2009.2014707

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 10 references

Research works printed but not linked: 3

  1. zou, 2008, a 1-v 1.1-<ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> sensor interface ic for wearable biomedical devices, Proc IEEE Int Symp Circuits and Systems (ISCAS 2008), 2725
  2. wu, 2006, a 1 v 2.3 <ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> biomedical signal acquisition ic, IEEE ISSCC Dig Tech Papers, 58
  3. 1998, Medical Instrumentation Application and Design, 259

Cited by

See all 457

Metadata

Authors
Zou, X., Xu, X., Yao, L., & Lian, Y.
Affiliations
National University of Singapore (SG)
Venue
IEEE Journal of Solid-State Circuits
Published
2009-04
Volume
44
Issue
4
Pages
1067-1077
ISSN
0018-9200 (ISSN-L)
OpenAlex
W2152776190
Cited by
414
References
10
Citations by year
2026: 6 · 2025: 16 · 2024: 16 · 2023: 9 · 2022: 12 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 27 · 2017: 31 · 2016: 35 · 2015: 35 · 2014: 40 · 2013: 31 · 2012: 29
FWCI
16.02
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Journal of Solid-State Circuits (publishedVersion)
  • National University of Singapore (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
low-power analog front-end, low-voltage operation, low noise amplifier, tunable bandpass filter, successive approximation register ADC, relaxation oscillator, heartbeat detection, ECG recording, noise efficiency factor, CMOS integrated circuit

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A 1-V 450-nW fully integrated programmable biomedical sensor interface chip. https://app.cochat.ai/papers/10.1109/jssc.2009.2014707
The paper
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009). A 1-V 450-nW fully integrated programmable biomedical sensor interface chip. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2009.2014707

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.