Near-infrared (nir) tomography breast image reconstruction with a priori structural information from mri: algorithm development for reconstructing heterogeneities
The DOI matches its Crossref record.
Abstract
A combined magnetic resonance and near-infrared (MRI-NIR) imaging modality can potentially yield high resolution maps of optical properties from noninvasive simultaneous measurement. The main disadvantage of near-infrared (NIR) tomography lies in the low spatial resolution resulting from the highly scattering nature of tissue for these wavelengths. MRI has achieved high resolution, but suffers from low specificity. In this study, NIR image reconstruction algorithms that incorporate a priori structural information provided by MRI are investigated in an attempt to optimize recovery of a simulated optical property distribution. The effect of high levels of tissue heterogeneity are evaluated to determine the limitations of incorporating prior information into a realistic set of patient breast images. We assume absorption coefficient (μa) variations near ±40%, and transport scattering coefficient (μ/sub s//sup //) variations near ±20%, in a coronal breast MRI geometry. Changes in tissue pathology due to tumor growth can be observed with NIR tompgraphy, and so the goal here is to determine how best to quantify these tumor-based contrast regions within the presence of high tissue heterogeneity. By applying knowledge of tissue's layered structure in reconstruction through various constraints in the iterative algorithm, quantitative recovery of the tumor optical properties improves from 69% to 74%, and localization improves as well. However, only when the true heterogeneity of the tissue distribution was included was accurate quantification of the tumor region possible. Using a good initial guess of μaand μ/sub s//sup //, derived from the regional structure of the model, quantification of the region reaches 99% of the true value, and spatial resolution retains a similar value to the original MRI image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Heijblom, M., Piras, D., Xia, W., van Hespen, J. C. G., Klaase, J. M., van den Engh, F. M., van Leeuwen, T. G., Steenbergen, W., & Manohar, S. (2012) · Optics Express · doi:10.1364/oe.20.011582 · Cited by 199
Gibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
Self-citationCong, Z., Yang, F., Cao, L., Wen, H., Fu, T., Ma, S., Liu, C., Quan, L., & Liao, Y. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s185726 · Cited by 23
“Nonetheless, NIR fluorescence imaging can achieve high penetration depth, yet they often confer low spatial resolution.(16) Multispectral optoacoustic tomography (MSOT) is a noninvasive imaging method based on photoacoustic effect.”
Background
Metadata
- Authors
- Brooksby, B. A., Dehghani, H., Pogue, B. W., & Paulsen, K. D.
- Venue
- IEEE Journal of Selected Topics in Quantum Electronics
- Published
- 2003-03
- Volume
- 9
- Issue
- 2
- Pages
- 199-209
- ISSN
- 1077-260X (ISSN-L)
- OpenAlex
- W2126807619
- Cited by
- 174
- References
- 0
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.