Highly Accurate THz Time-Domain Spectroscopy of Multilayer Structures
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We extract the optical material parameters of a layer within a multilayer sample from terahertz (THz) time-domain spectroscopy data. To this aim, we derive a suited transfer function for multilayer structures in general and use the recently introduced spatially variant moving average filter to improve the accuracy of the algorithm. We demonstrate two applications of our method experimentally: the determination of the thickness and optical material parameters of an unknown layer on a substrate and the investigation of liquids in a known cuvette.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239 · cited 1×
“The mode of operation of a THz TDS relies on comparing a broadband pulse, referred to as a THz pulse, transmitted through air with the same pulse detected after passing through the investigated sample [1]–[5].”
BackgroundMaterial parameter estimation with terahertz time-domain spectroscopy
Dorney, T. D., Baraniuk, R. G., & Mittleman, D. M. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001562 · Cited by 807
Duvillaret, L., Garet, F., & Coutaz, J.-L. (1999) · Applied Optics · doi:10.1364/ao.38.000409 · Cited by 505 · cited 2×
“Here, we use the same assumptions about the ray propagations as is done in [3]–[5].”
BackgroundMethodHighly accurate optical material parameter determination with THz time-domain spectroscopy
Pupeza, I., Wilk, R., & Koch, M. (2007) · Optics Express · doi:10.1364/oe.15.004335 · Cited by 351
Self-citationTHz time-domain spectroscopy of nonpolar liquids
Pedersen, J. E., & Keiding, S. R. (1992) · IEEE Journal of Quantum Electronics · doi:10.1109/3.159558 · Cited by 153
Terahertz spectroscopy of optically thick multilayered semiconductor structures
Ralph, S. E., Perkowitz, S., Katzenellenbogen, N., & Grischkowsky, D. (1994) · Journal of the Optical Society of America B · doi:10.1364/josab.11.002528 · Cited by 44
Cited by
Baxter, J. B., & Guglietta, G. W. (2011) · Analytical Chemistry · doi:10.1021/ac200907z · Cited by 477
Terahertz time-domain spectroscopy
Koch, M., Mittleman, D. M., Ornik, J., & Castro-Camus, E. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00232-z · Cited by 410
Self-citationParrott, E. P., Zeitler, J. A., & Gladden, L. F. (2009) · Optics Letters · doi:10.1364/ol.34.003722 · Cited by 47
Tayvah, U., Spies, J. A., Neu, J., & Schmuttenmaer, C. A. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c02132 · Cited by 41
Periodic sampling errors in terahertz time-domain measurements
Rehn, A., Jahn, D., Balzer, J. C., & Koch, M. (2017) · Optics Express · doi:10.1364/oe.25.006712 · Cited by 32
Self-citation
Metadata
- Authors
- Wilk, R., Pupeza, I., Cernat, R., & Koch, M.
- Venue
- IEEE Journal of Selected Topics in Quantum Electronics
- Published
- 2008
- Volume
- 14
- Issue
- 2
- Pages
- 392-398
- ISSN
- 1077-260X (ISSN-L)
- OpenAlex
- W2097731840
- Cited by
- 78
- References
- 6
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Accurate THz Time-Domain Spectroscopy of Multilayer Structures. https://app.cochat.ai/papers/10.1109/jstqe.2007.910981
- The paper
- Wilk, R., Pupeza, I., Cernat, R., & Koch, M. (2008). Highly Accurate THz Time-Domain Spectroscopy of Multilayer Structures. IEEE Journal of Selected Topics in Quantum Electronics. https://doi.org/10.1109/jstqe.2007.910981
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.