Survey of Techniques and Architectures for Designing Energy-Efficient Data Centers
The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Abstract
Cloud computing has emerged as the leading paradigm for information technology businesses. Cloud computing provides a platform to manage and deliver computing services around the world over the Internet. Cloud services have helped businesses utilize computing services on demand with no upfront investments. The cloud computing paradigm has sustained its growth, which has led to increase in size and number of data centers. Data centers with thousands of computing devices are deployed as back end to provide cloud services. Computing devices are deployed redundantly in data centers to ensure 24/7 availability. However, many studies have pointed out that data centers consume large amount of electricity, thus calling for energy-efficiency measures. In this survey, we discuss research issues related to conflicting requirements of maximizing quality of services (QoSs) (availability, reliability, etc.) delivered by the cloud services while minimizing energy consumption of the data center resources. In this paper, we present the concept of inception of data center energy-efficiency controller that can consolidate data center resources with minimal effect on QoS requirements. We discuss software- and hardware-based techniques and architectures for data center resources such as server, memory, and network devices that can be manipulated by the data center controller to achieve energy efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McKeown (2008) · doi:10.1145/1355734.1355746 · Cited by 8,513
Cloud computing: state-of-the-art and research challenges
Zhang, Q., Cheng, L., & Boutaba, R. (2010) · Journal of Internet Services and Applications · doi:10.1007/s13174-010-0007-6 · Cited by 3,515 · cited 1×
“In the following sections, we will discuss the storage architectures, emerging energy-efficient storage technologies, and DRAM architectures in the context of data centers.”
BackgroundA scalable, commodity data center network architecture
Al-Fares, M., Loukissas, A., & Vahdat, A. (2008) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1402946.1402967 · Cited by 3,175
VL2: a scalable and flexible data center network
Greenberg, A., Hamilton, J. R., Jain, N., Kandula, S., Kim, C., Lahiri, P., Maltz, D. A., Patel, P., & Sengupta, S. (2009) · Proceedings of the ACM SIGCOMM 2009 conference on Data communication · doi:10.1145/1592568.1592576 · Cited by 2,111 · cited 1×
“However, there are serious issues regarding tiered data center topologies: a) High-end switches result in oversubscribed links in data center networks, which results in limited server-to-server bandwidth [89]; b) the routing designs in tiered data center architectures create fragmentation of server resources and addre…”
BackgroundPower provisioning for a warehouse-sized computer
Fan, X., Weber, W.-D., & Barroso, L. A. (2007) · Proceedings of the 34th annual international symposium on Computer architecture · doi:10.1145/1250662.1250665 · Cited by 1,797 · cited 1×
“The gap between the theoretical and actual peak power utilization of cluster servers allows the deployment of additional computing devices under the same power budget.”
BackgroundBCube: a high performance, server-centric network architecture for modular data centers
Guo, C., Lu, G., Li, D., Wu, H., Zhang, X., Shi, Y., Tian, C., Zhang, Y., & Lu, S. (2009) · Proceedings of the ACM SIGCOMM 2009 conference on Data communication · doi:10.1145/1592568.1592577 · Cited by 1,372 · cited 5×
“[86] C. Guo, H. Wu, K. Tan, L. Shi, Y. Zhang, and S. Lu, “DCell: A scalable and fault-tolerant network structure for data centers,” in Proc.”
BackgroundInfluentialDcell: a scalable and fault-tolerant network structure for data centers
Guo, C., Wu, H., Tan, K., Shi, L., Zhang, Y., & Lu, S. (2008) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1402946.1402968 · Cited by 994
(2010) · doi:10.5555/1855711.1855728 · Cited by 970
Helios: a hybrid electrical/optical switch architecture for modular data centers
Farrington, N., Porter, G., Radhakrishnan, S., Bazzaz, H. H., Subramanya, V., Fainman, Y., Papen, G., & Vahdat, A. (2010) · Proceedings of the ACM SIGCOMM 2010 conference · doi:10.1145/1851182.1851223 · Cited by 918 · cited 5×
“Several electrical–optical hybrid data center network architectures have been also proposed to provide energyefficient network operations in data centers [94].”
BackgroundInfluentialA durable and energy efficient main memory using phase change memory technology
Zhou, P., Zhao, B., Yang, J., & Zhang, Y. (2009) · Proceedings - International Symposium on Computer Architecture/Proceedings · doi:10.1145/1555754.1555759 · Cited by 912 · cited 6×
“Emerging main memory technologies such as phase-change memory (PCM) [66], [71], CMOS, spin-torque transfer RAM [72], and memristor [73] have been also proposed as energyefficient main memory alternatives.”
BackgroundInfluentialPowerNap: eliminating server idle power
Meisner, D., Gold, B. T., & Wenisch, T. F. (2009) · Proceedings of the 14th international conference on Architectural support for programming languages and operating systems · doi:10.1145/1508244.1508269 · Cited by 901 · cited 1×
“Meisner et al. [43] argue that the PDUs’ efficiency remains in green zone above 80% for server utilization.”
BackgroundPower provisioning for a warehouse-sized computer
Fan, X., Weber, W.-D., & Barroso, L. A. (2007) · ACM SIGARCH Computer Architecture News · doi:10.1145/1273440.1250665 · Cited by 662
GPUs and the Future of Parallel Computing
Keckler, S. W., Dally, W. J., Khailany, B., Garland, M., & Glasco, D. (2011) · IEEE Micro · doi:10.1109/mm.2011.89 · Cited by 658 · cited 1×
“1 GPUs provide nearly 85 times lesser power consumption for a floating-point calculation than x86-based processors [38].”
BackgroundEnergy-aware server provisioning and load dispatching for connection-intensive internet services
Gong, C., He, W., Liu, J., Nath, S., Rigas, L., Xiao, L., & Zhao, F. (2008) · Cited by 654
Making scheduling cool: temperature-aware workload placement in data centers
Moore, J., Chase, J., Ranganathan, P., & Sharma, R. K. (2005) · USENIX Annual Technical Conference · Cited by 651
No "power" struggles: coordinated multi-level power management for the data center
Raghavendra, R., Ranganathan, P., Talwar, V., Wang, Z., & Zhu, X. (2008) · Proceedings of the 13th international conference on Architectural support for programming languages and operating systems · doi:10.1145/1346281.1346289 · Cited by 619 · cited 2×
“Researchers have proposed a power capping scheme for data centers that require coordination among various data center resources, such as virtual machines, blade servers, racks, and containers [21].”
BackgroundReport to Congress on Server and Data Center Energy Efficiency: Public Law 109-431
Alliance to Save Energy, & Ernest Orlando Lawrence Berkeley National Laboratory, B. (2007) · doi:10.2172/929723 · Cited by 589 · cited 4×
“DaaS facilities maintaining user data have to meet the often conflicting requirements of high availability, redundancy, and energy efficiency [2].”
BackgroundInfluentialDcell: a scalable and fault-tolerant network structure for data centers
Guo, C., Wu, H., Tan, K., Shi, L., Zhang, Y., & Lu, S. (2008) · Proceedings of the ACM SIGCOMM 2008 conference on Data communication · doi:10.1145/1402958.1402968 · Cited by 563 · cited 7×
“[88] C. Guo, G. Lu, D. Li, H. Wu, X. Zhang, Y. Shi, C. Tian, Y. Zhang, and S. Lu, “BCube: A high performance, server-centric network architecture for modular data centers,” SIGCOMM Comput.”
BackgroundMethodInfluentialFAWN: a fast array of wimpy nodes
Andersen, D. G., Franklin, J., Kaminsky, M., Phanishayee, A., Tan, L., & Vasudevan, V. (2009) · Proceedings of the ACM SIGOPS 22nd symposium on Operating systems principles · doi:10.1145/1629575.1629577 · Cited by 561
BCube: a high performance, server-centric network architecture for modular data centers
Guo, C., Lu, G., Li, D., Wu, H., Zhang, X., Shi, Y., Tian, C., Zhang, Y., & Lu, S. (2009) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1594977.1592577 · Cited by 535
Multi-Objective Virtual Machine Placement in Virtualized Data Center Environments
Xu, J., & Fortes, J. A. B. (2010) · 2010 IEEE/ACM Int'l Conference on Green Computing and Communications & Int'l Conference on Cyber, Physical and Social Computing · doi:10.1109/greencom-cpscom.2010.137 · Cited by 529 · cited 2×
“However, researchers have advocated the usage of commodity low-cost low-power cores for scale-out applications for increased performance per dollar rather than increased performance/server metric.”
BackgroundThe case for RAMClouds: scalable high-performance storage entirely in DRAM
Ousterhout, J., Agrawal, P., Erickson, D., Kozyrakis, C., Leverich, J., Mazières, D., Mitra, S., Narayanan, A., Parulkar, G., Rosenblum, M., et al. (2010) · ACM SIGOPS Operating Systems Review · doi:10.1145/1713254.1713276 · Cited by 447 · cited 1×
“RAMCloud, based entirely on DRAM components from commodity servers [76].”
MethodReducing the Energy Consumption of Ethernet with Adaptive Link Rate (ALR)
Gunaratne, C., Christensen, K. J., Bruce Nordman, B., & Suen, S. (2008) · IEEE Transactions on Computers · doi:10.1109/tc.2007.70836 · Cited by 414 · cited 1×
“The mechanisms to implement an ALR technique can be: a) medium access control (MAC) frame handshake protocol in which the sender and receiver adjust data rates through MAC frames [83], b) ALR autonegotiation protocol that permits communicating devices to set data rate and flow control parameters [84]; and c) IEEE Ener…”
MethodEnergy proportional datacenter networks
Abts, D., Marty, M. R., Wells, P. M., Klausler, P., & Liu, H. (2010) · Proceedings of the 37th annual international symposium on Computer architecture · doi:10.1145/1815961.1816004 · Cited by 414
IEEE 802.3az: the road to energy efficient ethernet
Christensen, K. J., Reviriego, P., Nordman, B., Bennett, M., Mostowfi, M., & Maestro, J. A. (2010) · IEEE Communications Magazine · doi:10.1109/mcom.2010.5621967 · Cited by 377
Ensemble-level Power Management for Dense Blade Servers
Ranganathan, P., Leech, P., Irwin, D., & Chase, J. (2006) · ACM SIGARCH Computer Architecture News · doi:10.1145/1150019.1136492 · Cited by 357 · cited 2×
“Therefore, designing densely populated computing modules requires careful consideration of power density, clock frequency, and system throughput [30].”
Memory power management via dynamic voltage/frequency scaling
David, H., Fallin, C., Gorbatov, E., Hanebutte, U. R., & Mutlu, O. (2011) · Proceedings of the 8th ACM international conference on Autonomic computing · doi:10.1145/1998582.1998590 · Cited by 334 · cited 1×
“and registers [77].”
GreenCloud: A Packet-Level Simulator of Energy-Aware Cloud Computing Data Centers
Kliazovich, D., Bouvry, P., Audzevich, Y., & Khan, S. U. (2010) · 2010 IEEE Global Telecommunications Conference GLOBECOM 2010 · doi:10.1109/glocom.2010.5683561 · Cited by 299
Self-citationHibernator: helping disk arrays sleep through the winter
Zhu, Q., Chen, Z., Tan, L., Zhou, Y., Keeton, K., & Wilkes, J. (2005) · ACM SIGOPS Operating Systems Review · doi:10.1145/1095809.1095828 · Cited by 287
Aquasar: A hot water cooled data center with direct energy reuse
Zimmermann, S., Meijer, I., Tiwari, M. K., Paredes, S., Michel, B., & Poulikakos, D. (2012) · Energy · doi:10.1016/j.energy.2012.04.037 · Cited by 276 · cited 1×
“In the following sections, we will discuss the storage architectures, emerging energy-efficient storage technologies, and DRAM architectures in the context of data centers.”
BackgroundGordon: using flash memory to build fast, power-efficient clusters for data-intensive applications
Caulfield, A. M., Grupp, L. M., & Swanson, S. (2009) · International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS) · doi:10.1145/1508244.1508270 · Cited by 265 · cited 1×
“Researchers [63] proposed a flash controller to manage an array of Flash drives and implement FTL.”
BackgroundResearch on mobile cloud computing: Review, trend and perspectives
Qi, H., & Gani, A. (2012) · 2012 Second International Conference on Digital Information and Communication Technology and it's Applications (DICTAP) · doi:10.1109/dictap.2012.6215350 · Cited by 256 · cited 1×
“IT technologies, including cloud and mobile cloud computing, have become a major consumer of energy due to rapid growth and integration with many industries [3], [4].”
BackgroundKant, K. (2009) · Computer Networks · doi:10.1016/j.comnet.2009.10.004 · Cited by 241
DENS: Data Center Energy-Efficient Network-Aware Scheduling
Kliazovich, D., Bouvry, P., & Khan, S. U. (2010) · 2010 IEEE/ACM Int'l Conference on Green Computing and Communications & Int'l Conference on Cyber, Physical and Social Computing · doi:10.1109/greencom-cpscom.2010.31 · Cited by 239
Self-citationCyberentity Security in the Internet of Things
Ning, H., Liu, H., & Yang, L. T. (2013) · Computer · doi:10.1109/mc.2013.74 · Cited by 234
Symbiotic routing in future data centers
Abu-Libdeh, H., Costa, P., Rowstron, A., O'Shea, G., & Donnelly, A. (2010) · Proceedings of the ACM SIGCOMM 2010 conference · doi:10.1145/1851182.1851191 · Cited by 227 · cited 1×
“To overcome oversubscription ratio and remove bandwidth bottleneck: a) server-centric [85] and hybrid [86] network architectures have been adopted; and b) 100-Gb Ethernet solutions have been proposed [62].”
MethodFiber optic communication technologies: What's needed for datacenter network operations
Lam, C., Liu, H., Koley, B., Zhao, X., Kamalov, V., & Gill, V. (2010) · IEEE Communications Magazine · doi:10.1109/mcom.2010.5496876 · Cited by 215 · cited 1×
“Although fiber optic cabling provides high-speed and energy-efficient storage networking technology, it is cost prohibitive [62].”
BackgroundBest Practices for Data Centers: Lessons Learned from Benchmarking 22 Data Centers
Greenberg, S., Mills, E., Tschudi, B., & Rumsey, P. (2006) · Cited by 214
A taxonomy and survey on Green Data Center Networks
Bilal, K., Malik, S. U. R., Khalid, O., Hameed, A., Alvarez, E., Wijaysekara, V., Irfan, R., Shrestha, S., Dwivedy, D., Ali, M., et al. (2014) · Future Generation Computer Systems · doi:10.1016/j.future.2013.07.006 · Cited by 201
Self-citationA durable and energy efficient main memory using phase change memory technology
Zhou, P., Zhao, B., Yang, J., et al. (2009) · ACM SIGARCH Computer Architecture News · doi:10.1145/1555815.1555759 · Cited by 192
Energy-aware routing in data center network
Shang, Y., Li, D., & Xu, M. (2010) · ACM SIGCOMM Workshop on Green Networking (GreenNet) · doi:10.1145/1851290.1851292 · Cited by 178 · cited 1×
“[95] put forward the idea of energy-aware routing where few network devices provide the basic routing and throughput according to a performance threshold while the rest of devices are powered off.”
BackgroundMeisner, D., Gold, B. T., & Wenisch, T. F. (2009) · ACM SIGPLAN Notices · doi:10.1145/1508284.1508269 · Cited by 171
SRCMap: energy proportional storage using dynamic consolidation
Verma, A., Koller, R., Useche, L., & Rangaswami, R. (2010) · doi:10.5555/1855511.1855531 · Cited by 158
Potential of air-side economizers for data center cooling: A case study for key Australian cities
Siriwardana, J., Jayasekara, S., & Halgamuge, S. K. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.10.046 · Cited by 142
ServerSwitch: a programmable and high performance platform for data center networks
Lu, G., Guo, C., Li, Y., Zhou, Z., Yuan, T., Wu, H., Xiong, Y., Gao, R., & Zhang, Y. (2011) · doi:10.5555/1972457.1972460 · Cited by 141
Impact of process variations on emerging memristor
Niu, D., Chen, Y., Xu, C., & Xie, Y. (2010) · ACM/IEEE Design Automation Conference (DAC) · doi:10.1145/1837274.1837495 · Cited by 139 · cited 1×
“Emerging main memory technologies such as phase-change memory (PCM) [66], [71], CMOS, spin-torque transfer RAM [72], and memristor [73] have been also proposed as energyefficient main memory alternatives.”
BackgroundMicro-pages: increasing DRAM efficiency with locality-aware data placement
Sudan, K., Chatterjee, N., Nellans, D. W., Awasthi, M., Balasubramonian, R., & Davis, A. (2010) · ACM SIGARCH Computer Architecture News · doi:10.1145/1735970.1736045 · Cited by 139
Shuja, J., Madani, S. A., Bilal, K., Hayat, K., Khan, S. U., & Sarwar, S. (2012) · Computing · doi:10.1007/s00607-012-0211-2 · Cited by 135
Self-citationRaghavendra (2008) · doi:10.1145/1353534.1346289 · Cited by 134
Cooling Energy-Hungry Data Centers
Meijer, G. I. (2010) · Science · doi:10.1126/science.1182769 · Cited by 126 · cited 4×
“There are two thermal management techniques in data centers: a) air-flow-based solution; and b) fluid-based solution [8].”
BackgroundMethodInfluentialEnergy-efficient networking: past, present, and future
Zeadally, S., Khan, S. U., & Chilamkurti, N. (2011) · The Journal of Supercomputing · doi:10.1007/s11227-011-0632-2 · Cited by 124 · cited 2×
“many veteran industries and businesses [1].”
BackgroundSelf-citationQuantitative comparisons of the state‐of‐the‐art data center architectures
Bilal, K., Khan, S. U., Zhang, L., Li, H., Hayat, K., Madani, S. A., Min‐Allah, N., Wang, L., Chen, D., Iqbal, M., et al. (2012) · Concurrency and Computation Practice and Experience · doi:10.1002/cpe.2963 · Cited by 123 · cited 1×
“Power consumption in network devices can be managed through adaptive link rate (ALR) techniques [79], [80].”
BackgroundSelf-citationLi, C., Qouneh, A., & Li, T. (2012) · ACM SIGARCH Computer Architecture News · doi:10.1145/2366231.2337218 · Cited by 115 · cited 1×
“In the following sections, we will discuss the storage architectures, emerging energy-efficient storage technologies, and DRAM architectures in the context of data centers.”
BackgroundPower routing: dynamic power provisioning in the data center
Pelley, S., Meisner, D., Zandevakili, P., Wenisch, T. F., & Underwood, J. (2010) · ACM SIGARCH Computer Architecture News · doi:10.1145/1735970.1736047 · Cited by 111
Security-aware optimization for ubiquitous computing systems with SEAT graph approach
Qiu, M., Zhang, L., Ming, Z., Chen, Z. D., Qin, X., & Yang, L. T. (2012) · Journal of Computer and System Sciences · doi:10.1016/j.jcss.2012.11.002 · Cited by 111
System power management support in the IBM POWER6 microprocessor
Floyd, M. S., Ghiasi, S., Keller, T., Rajamani, K., Rawson, F. L., Rubio, J. C., & Ware, M. (2007) · IBM Journal of Research and Development · doi:10.1147/rd.516.0733 · Cited by 105 · cited 1×
“Modern servers are equipped with dynamic power management solutions to cap local power budget [41].”
BackgroundSolarCore: Solar energy driven multi-core architecture power management
Li, C., Zhang, W., Cho, C.-B., & Li, T. (2011) · IEEE International Symposium on High-Performance Computer Architecture (HPCA) · doi:10.1109/hpca.2011.5749729 · Cited by 104 · cited 1×
“In the following sections, we will discuss the storage architectures, emerging energy-efficient storage technologies, and DRAM architectures in the context of data centers.”
BackgroundSymbiotic routing in future data centers
Abu-Libdeh, H., Costa, P., Rowstron, A., O'Shea, G., & Donnelly, A. (2010) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1851275.1851191 · Cited by 90
Adaptive energy-efficient scheduling for real-time tasks on DVS-enabled heterogeneous clusters
Zhu, X., He, C., Li, K., & Qin, X. (2012) · Journal of Parallel and Distributed Computing · doi:10.1016/j.jpdc.2012.03.005 · Cited by 88 · cited 1×
“Many researchers have proposed DVFS techniques for power efficiency in data centers [5], [24].”
BackgroundLow-power amdahl-balanced blades for data intensive computing
Szalay, A. S., Bell, G. C., Huang, H. H., Terzis, A., & White, A. (2010) · ACM SIGOPS Operating Systems Review · doi:10.1145/1740390.1740407 · Cited by 79 · cited 1×
“Moreover, multiprocessor SoC parallelization can impose significant overhead of interprocessor communications [33], [34].”
BackgroundWang, Y., Liu, H., Liu, D., Qin, Z., Shao, Z., & Sha, E. H. ‐. (2011) · ACM Transactions on Design Automation of Electronic Systems · doi:10.1145/1929943.1929946 · Cited by 76
On energy efficiency for enterprise and data center networks
Mahadevan, P., Banerjee, S., Sharma, P. K., Shah, A. J., & Ranganathan, P. (2011) · IEEE Communications Magazine · doi:10.1109/mcom.2011.5978421 · Cited by 75 · cited 1×
“ited number of switches [92].”
A survey on Green communications using Adaptive Link Rate
Bilal, K., Khan, S. U., Madani, S. A., Khizar Hayat, A., Khan, M. I., Min‐Allah, N., Kołodziej, J., Wang, L., Zeadally, S., & Chen, D. (2012) · Cluster Computing · doi:10.1007/s10586-012-0225-8 · Cited by 70 · cited 3×
“The ALR techniques achieve energy efficiency by either: a) lower data rates; or b) lower power/idle (LPI) state transitions that are managed according to the data loads [81].”
BackgroundMethodInfluentialSelf-citationAutonomic Power & Performance Management for Large-Scale Data Centers
Khargharia, B., Hariri, S., Szidarovszky, F., Houri, M., El-Rewini, H., Khan, S. U., Ahmad, I., & Yousif, M. S. (2007) · 2007 IEEE International Parallel and Distributed Processing Symposium · doi:10.1109/ipdps.2007.370510 · Cited by 60
Self-citationOpportunities and challenges to unify workload, power, and cooling management in data centers
Wang, Z., Tolia, N., & Bash, C. E. (2010) · doi:10.1145/1791204.1791205 · Cited by 39
Challenges and Opportunities for Extremely Energy-Efficient Processors
Mudge, T., & Hölzle, U. (2010) · IEEE Micro · doi:10.1109/mm.2010.61 · Cited by 33 · cited 1×
“Processing capacity, memory, I/O, and network bandwidth need to be increased in balance so that the performance of one component does not bottleneck the performance of the whole system [32].”
BackgroundPower routing: dynamic power provisioning in the data center
Pelley, S., Meisner, D., Zandevakili, P., Wenisch, T. F., & Underwood, J. (2010) · ACM SIGPLAN Notices · doi:10.1145/1735971.1736047 · Cited by 32
The Search for Energy-Efficient Building Blocks for the Data Center
Keys, L., Rivoire, S., & Davis, J. D. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-24322-6_15 · Cited by 29 · cited 1×
“A similar study [37] conducted on seven different server class designs showed that mobile class systems are 80% and 300% energy efficient than the embedded class systems and volume servers, respectively.”
BackgroundCloudAC: a cloud‐oriented multilayer access control system for logic virtual domain
Qiang, W., Zou, D., Wang, S., Yang, L. T., Jin, H., & Shi, L. (2013) · IET Information Security · doi:10.1049/iet-ifs.2012.0094 · Cited by 7 · cited 1×
“Researchers have proposed a resource optimization strategy composed of confidentiality, integrity, and authentication measures considering real-time computation and deadline constraints [19].”
Background
Cited by
Data Center Energy Consumption Modeling: A Survey
Dayarathna, M., Wen, Y., & Fan, R. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2481183 · Cited by 1,165
Energy efficiency in cloud computing data centers: a survey on software technologies
Katal, A., Dahiya, S., & Choudhury, T. (2023) · Cluster Computing · doi:10.1007/s10586-022-03713-0 · Cited by 516
“In addition, the authors in [13] highlighted research difficulties connected to the competing needs of enhancing the quality of services (QoSs) supplied by cloud services while lowering energy consumption of data centre resources.”
BackgroundGreen Internet of Things for Smart World
Zhu, C., Leung, V. C. M., Shu, L., & Ngai, E. C.-H. (2015) · IEEE Access · doi:10.1109/access.2015.2497312 · Cited by 494
Green IoT for Eco-Friendly and Sustainable Smart Cities: Future Directions and Opportunities
Almalki, F. A., Alsamhi, S. H., Sahal, R., Hassan, J., Hawbani, A., Rajput, N. S., Saif, A., Morgan, J., & Breslin, J. (2023) · Mobile Networks and Applications · doi:10.1007/s11036-021-01790-w · Cited by 376
A Survey of Mobile Device Virtualization: Taxonomy and State of the Art
Shuja, J., Gani, A., Bilal, K., Khan, A. U. R., Madani, S. A., Khan, S. U., & Zomaya, A. Y. (2017) · ACM Computing Surveys · doi:10.1145/2897164 · Cited by 370
Self-citation
Metadata
- Authors
- Shuja, J., Bilal, K., Madani, S. A., Othman, M., Ranjan, R., Balaji, P., & Khan, S. U.
- Venue
- IEEE Systems Journal
- Published
- 2016-06
- Volume
- 10
- Issue
- 2
- Pages
- 507-519
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- 2373-7816
- OpenAlex
- W2315342500
- Cited by
- 218
- References
- 69
- FWCI
- 49.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.