A Comparison of Pattern Recognition Control and Direct Control of a Multiple Degree-of-Freedom Transradial Prosthesis

Open access
Kuiken, Todd A., Miller, Laura A., Turner, Kristi, Hargrove, Levi J. · 2016 · IEEE Journal of Translational Engineering in Health and Medicine
Cited by 135

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

With existing conventional prosthesis control (direct control), individuals with a transradial amputation use two opposing muscle groups to control each prosthesis motor. As component complexity increases, subjects must switch the prosthesis into different modes to control each component in sequence. Pattern recognition control offers the ability to control multiple movements in a seamless manner without switching. In this paper, three individuals with a transradial amputation completed a home trial to compare direct control and pattern recognition control of a multiple degree-of-freedom prosthesis. Outcome measures before and after the home trial, together with subject questionnaires, were used to evaluate functional control. Although small, this trial has implications for the implementation of pattern recognition in commercial control systems and for future research studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jtehm.2016.2616123

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 17

  1. 10.1109/TNSRE.2013.2247421 · DOI · Paper page
  2. 10.1109/TBME.2011.2155063 · DOI · Paper page
  3. 10.1109/TBME.2005.856295 · DOI · Paper page
  4. 10.1109/TNSRE.2010.2100828 · DOI · Paper page
  5. 10.5014/ajot.39.6.386 · DOI · Paper page
  6. jebsen, 1969, An objective and standardized test of hand function, Arch Phys Med Rehabil, 50, 311
  7. 10.1109/TNSRE.2007.911817 · DOI · Paper page
  8. 10.1097/JPO.0b013e3181ae974d · DOI
  9. 10.1016/j.gaitpost.2009.11.007 · DOI
  10. 10.1682/JRRD.2010.09.0177 · DOI · Paper page
  11. 10.1097/JPO.0b013e3182515437 · DOI · Paper page
  12. michael, 2004, Externally powered prostheses for the adult transradial and wrist disarticulation amputee, Functional Restoration of Adults and Children with Upper Extremity Amputation, 187
  13. 10.1371/journal.pone.0112091 · DOI
  14. williams, 2004, Control of powered upper extremity prostheses, Functional Restoration of Adults and Children with Upper Extremity Amputation, 207
  15. 10.1109/TNSRE.2015.2492619 · DOI · Paper page
  16. 10.1088/1741-2560/12/4/046005 · DOI · Paper page
  17. 10.1109/EMBC.2012.6346318 · DOI

Cited by

See all 135

Metadata

Authors
Kuiken, T. A., Miller, L. A., Turner, K., & Hargrove, L. J.
Venue
IEEE Journal of Translational Engineering in Health and Medicine
Published
2016
Volume
4
Pages
1-8
ISSN
2168-2372 (ISSN-L)
OpenAlex
W2549648117
Cited by
135
References
3
FWCI
5.32
Type
journal article
Language
en
Open access
gold
Funders
  • National Institutes of Health (R01 HD043137-01, R01 HD044798-01)
  • Department of Education, National Institute on Disability and Rehabilitation Research (H133G100107)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Pattern Recognition Control and Direct Control of a Multiple Degree-of-Freedom Transradial Prosthesis. https://app.cochat.ai/papers/10.1109/jtehm.2016.2616123
The paper
Kuiken, T. A., Miller, L. A., Turner, K., & Hargrove, L. J. (2016). A Comparison of Pattern Recognition Control and Direct Control of a Multiple Degree-of-Freedom Transradial Prosthesis. IEEE Journal of Translational Engineering in Health and Medicine. https://doi.org/10.1109/jtehm.2016.2616123

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.