The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Simultaneous control of multiple functions of bionic hand prostheses: Performance and robustness in end users
Abstract
A regression-based control approach allows for robust simultaneous and proportional myoelectric control of a hand prosthesis with two degrees of freedom.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417 · cited 1×
“Functional tasks such as the Southampton Hand Assessment Procedure (SHAP) test (28), the box-and-blocks test (29), and the clothespin relocation test (30) were evaluated and compared with a conventional control approach.”
Method
Research works printed but not linked: 33
- 10.1093/brain/121.9.1603 · DOI · Paper page
- E. D. Sherman, A Russian bioelectric-controlled prosthesis. Can. Med. Assoc. J. 91, 1268–1270 (1964).
- A. Muzumdar Powered Upper Limb Prostheses: Control Implementation and Clinical Application (Springer 2004). · doi:10.1007/978-3-642-18812-1
- 10.1016/j.jelekin.2006.08.006 · DOI · Paper page
- 10.1682/JRRD.2010.08.0161 · DOI · Paper page
- 10.1007/s00422-008-0278-1 · DOI · Paper page
- 10.1109/TBME.2012.2188799 · DOI
- 10.1109/TNSRE.2014.2361478 · DOI
- 10.1109/TBME.2012.2232293 · DOI · Paper page
- 10.1109/TBME.2008.2007967 · DOI · Paper page
- 10.1109/TNSRE.2014.2305520 · DOI · Paper page
- 10.1109/TNSRE.2011.2178039 · DOI · Paper page
- 10.1109/TNSRE.2014.2323576 · DOI · Paper page
- 10.1016/j.bspc.2014.03.006 · DOI
- 10.1109/TNSRE.2014.2305097 · DOI
- 10.1109/TBME.2010.2068298 · DOI · Paper page
- N. Jiang, S. Dosen, K. R. Müller, D. Farina, Myoelectric control of artificial limbs—Is there a need to change focus? IEEE Signal Process. Mag. 29, 148–152 (2012).
- 10.1109/TNSRE.2011.2163529 · DOI · Paper page
- 10.1109/TBME.2011.2159216 · DOI · Paper page
- 10.1371/journal.pone.0186318 · DOI
- C. Cipriani R. Sassu M. Controzzi M. C. Carrozza Influence of the weight actions of the hand prosthesis on the performance of pattern recognition based myoelectric control: Preliminary study in Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Boston MA 30 August to 3 September 2011 (IEEE 2011) pp. 1620–1623. · DOI
- S. Amsüss L. P. Paredes N. Rudigkeit B. Graimann M. J. Herrmann D. Farina Long term stability of surface EMG pattern classification for prosthetic control Conf. Proc. IEEE Eng. Med. Biol. Soc. 2013 3622–3625. · DOI
- 10.1007/BF00286094 · DOI
- 10.1109/JTEHM.2016.2616123 · DOI
- 10.5014/ajot.39.6.386 · DOI · Paper page
- 10.1177/0309364616660250 · DOI
- 10.1109/TNSRE.2015.2492619 · DOI · Paper page
- 10.1038/s41598-017-04255-x · DOI
- 10.1007/s11517-012-0979-4 · DOI
- 10.1109/TNSRE.2015.2401134 · DOI
- 10.1109/TNSRE.2007.891391 · DOI · Paper page
- 10.1016/j.bspc.2007.11.005 · DOI · Paper page
- 10.1088/1741-2560/12/4/046005 · DOI · Paper page
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationShi, C., Yang, D., Zhao, J., & Liu, H. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3007625 · Cited by 87
“developed based on a finite state machine (FSM) [7], pattern recognition [8], and neural decoding [9].”
BackgroundLukyanenko, P., Dewald, H. A., Lambrecht, J., Kirsch, R. F., Tyler, D. J., & Williams, M. R. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00833-3 · Cited by 27
Metadata
- Authors
- Hahne, J. M., Schweisfurth, M. A., Koppe, M., & Farina, D.
- Venue
- Science Robotics
- Published
- 2018-06-20
- Volume
- 3
- Issue
- 19
- ISSN
- 2470-9476 (ISSN-L)
- OpenAlex
- W2809139847
- Cited by
- 216
- References
- 3
- FWCI
- 9.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Funders
- H2020 European Research Council (687795)
- BMBF (INOPRO)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous control of multiple functions of bionic hand prostheses: Performance and robustness in end users. https://app.cochat.ai/papers/10.1126/scirobotics.aat3630
- The paper
- Hahne, J. M., Schweisfurth, M. A., Koppe, M., & Farina, D. (2018). Simultaneous control of multiple functions of bionic hand prostheses: Performance and robustness in end users. Science Robotics. https://doi.org/10.1126/scirobotics.aat3630
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.