Automated Assessment of Dynamic Knee Valgus and Risk of Knee Injury During the Single Leg Squat
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Many clinical assessment protocols of the lower limb rely on the evaluation of functional movement tests such as the single leg squat (SLS), which are often assessed visually. Visual assessment is subjective and depends on the experience of the clinician. In this paper, an inertial measurement unit (IMU)-based method for automated assessment of squat quality is proposed to provide clinicians with a quantitative measure of SLS performance. A set of three IMUs was used to estimate the joint angles, velocities, and accelerations of the squatting leg. Statistical time domain features were generated from these measurements. The most informative features were used for classifier training. A data set of SLS performed by healthy participants was collected and labeled by three expert clinical raters using two different labeling criteria: "observed amount of knee valgus" and "overall risk of injury". The results showed that both flexion at the hip and knee, as well as hip and ankle internal rotation are discriminative features, and that participants with "poor" squats bend the hip and knee less than those with better squat performance. Furthermore, improved classification performance is achieved for females by training separate classifiers stratified by gender. Classification results showed excellent accuracy, 95.7 % for classifying squat quality as "poor" or "good" and 94.6% for differentiating between high and no risk of injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Cicchetti, D. V. (1994) · Psychological Assessment · doi:10.1037/1040-3590.6.4.284 · Cited by 9,349
Computing Inter-Rater Reliability for Observational Data: An Overview and Tutorial
Hallgren, K. A. (2012) · Tutorials in Quantitative Methods for Psychology · doi:10.20982/tqmp.08.1.p023 · Cited by 3,884
A Survey on Human Activity Recognition using Wearable Sensors
Lara, O. D., & Labrador, M. A. (2013) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2012.110112.00192 · Cited by 2,662
Zeller, B. L., McCrory, J. L., Ben Kibler, W., & Uhl, T. L. (2003) · The American Journal of Sports Medicine · doi:10.1177/03635465030310032101 · Cited by 490
Performance on the Single-Leg Squat Task Indicates Hip Abductor Muscle Function
Crossley, K. M., Zhang, W.-J., Schache, A. G., Bryant, A., & Cowan, S. M. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510395456 · Cited by 360
What Are the Validity of the Single-Leg-Squat Test and Its Relationship to Hip-Abduction Strength?
DiMattia, M. A., Livengood, A. L., Uhl, T. L., Mattacola, C. G., & Malone, T. R. (2005) · Journal of Sport Rehabilitation · doi:10.1123/jsr.14.2.108 · Cited by 115
Weeks, B. K., Carty, C. P., & Horan, S. A. (2012) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-13-207 · Cited by 80
Levinger, P., Gilleard, W., & Coleman, C. (2007) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2007.03.003 · Cited by 74
Concurrent validity and reliability of clinical evaluation of the single leg squat
Poulsen, D. R., & James, C. R. (2011) · Physiotherapy Theory and Practice · doi:10.3109/09593985.2011.552539 · Cited by 35
Cited by
The Integration of Artificial Intelligence into Clinical Practice
Karalis, V. D. (2024) · Applied Biosciences · doi:10.3390/applbiosci3010002 · Cited by 255
“In this study, inertial sensor data were used to categorize the performance of single-leg squats based on the extent of knee valgus [111].”
MethodTeufl, W., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2019) · PLOS ONE · doi:10.1371/journal.pone.0213064 · Cited by 129
A Wearable, Multimodal Sensing System to Monitor Knee Joint Health
Teague, C. N., Heller, J. A., Nevius, B. N., Carek, A. M., Mabrouk, S., Garcia-Vicente, F., Inan, O. T., & Etemadi, M. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2994552 · Cited by 66
Metadata
- Authors
- Kianifar, R., Lee, A., Raina, S., & Kulic, D.
- Venue
- IEEE Journal of Translational Engineering in Health and Medicine
- Published
- 2017
- Volume
- 5
- Pages
- 1-13
- ISSN
- 2168-2372 (ISSN-L)
- OpenAlex
- W2766614313
- Cited by
- 72
- References
- 10
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.